Parametric Study of Posttensioned Inverted-T Bridge System for Improved Durability and Increased Span-to-Depth Ratio
Publication: Journal of Bridge Engineering
Volume 15, Issue 6
Abstract
Rehabilitation of the existing bridges is one of the most pressing needs in maintenance of the transportation infrastructure. As an example, more than 2,000 bridges in Kansas alone need to be replaced during the next decade. The majority of these bridges have spans of 30 m (100 ft) or less, and shallow profiles. The inverted-T (IT) bridge system has gained increasing popularity in recent years due to its lower weight and relatively larger span-to-depth ratio compared to the prestressed I-girder bridges. However, there are some limitations in replacing the existing cast in place (CIP) bridges with IT system. Implementation of posttensioning, which is the focus of this paper, is a promising solution for these limitations. This leads to a higher span-to-depth ratio and reduces potential transverse cracks in the CIP deck which is a major concern for corrosion of the reinforcement. An analytical research was conducted to identify the major parameters influencing the performance of a posttensioned IT bridge system. This was followed by a parametric study to explore the scope of these parameters and specify the design limits in terms of posttensioning stages, timing scenarios, and posttensioning forces. Concrete strength and different methods for estimating time-dependent restraining moments were addressed in this parametric study.
Get full access to this article
View all available purchase options and get full access to this article.
References
AASHTO. (2004). AASHTO LRFD bridge design specifications, customary U.S. units, 3rd Ed., Washington, D.C.
Ambare, S., and Peterman, R. J. (2006). “Evaluation of the inverted Tee shallow bridge system for use in Kansas,” Rep. No. K-TRAN: KSU-00-1, Kansas Dept. of Transportation, Topeka, Kan.
American Concrete Institute (ACI) Committee 209. (1992). “Prediction of creep, shrinkage, and temperature effects in concrete structures.” Rep. No. ACI 209R-92, Detroit.
Comite Euro-International du Beton-Federation International de la Precontrainte (CEB-FIP). (1990). CEB-FIP model code 90, design code, Paris.
Dilger, W. H. (1982). “Creep analysis of prestressed concrete structures using creep-transformed section properties.” PCI J., 27(1), 98–118.
Freyermuth, C. (1969). “Design of continuous highway bridges with precast prestressed concrete girders.” PCI J., 14(2), 14–39.
Kamel, M. R., and Derrick, D. (1997). “A precast alternative for bridge slabs.” Concr. Int., 19, 41–42.
Larson, K. H., Peterman, R. J., and Esmaeily, A. (2006). “Evaluating the time-dependent deformations of pretensioned bridge girders cast with self-consolidating concrete.” PCI National Bridge Conf. Proc., Grapevine, Tex.
Mattock, A. (1961). “Precast-prestressed concrete bridges 5: Creep and shrinkage studies.” J. PCA Research, 3, 32-66.
Oesterle, R., Glikin, J., and Larson, S. (1989a).“Design of simple-span precast prestressed bridge girders made continuous.” Final Rep., Construction Technology Laboratories, Inc. for National Cooperative Highway Research Program, Transportation Research Board (NCHRP Project 12-29), Skokie, Ill.
Oesterle, R., Glikin, J., and Larson, S. (1989b). “Design of precast-prestressed bridge girders made continuous.” National Cooperative Highway Research Program Rep. No. 322, Transportation Research Board, National Research Council, Washington, D.C.
Peterman, R., and Ramirez, J. (1998). “Restraint moments in bridges with full-span prestressed concrete form panels.” PCI J., 43, January-February, 54–73.
Information & Authors
Information
Published In
Copyright
© 2010 ASCE.
History
Received: May 13, 2008
Accepted: Feb 24, 2010
Published online: Mar 4, 2010
Published in print: Nov 2010
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.