Cyclic Testing of Replaceable Steel Coupling Beams with Reduced Beam Sections and Moment End-Plate Connections
Publication: Journal of Structural Engineering
Volume 148, Issue 10
Abstract
Coupled walls are a common lateral load resisting system for buildings located in seismic regions. Coupling beams create a ductile link between walls that increase the structure’s resistance to lateral forces and its ability to dissipate seismic energy. During a major seismic event, coupling beams dissipate energy by yielding and acting as a fuse. Replaceable steel coupling beams are an alternative to conventionally and diagonally-reinforced concrete coupling beams and offer the advantage of improved constructability and post-earthquake reparability. Previous studies on replaceable steel coupling beams have focused on shear yielding beams, while this study focused on flexure-yielding beams. Five two-third-scaled, cantilever steel coupling beams with reduced beam sections (RBSs) were tested under fully reversed cyclic loading. The primary test variables were parallel or single steel coupling beams, RBS cut geometry, and moment end-plate to embedded plate wall connection. Coupling beams with and without RBS cuts had deformation capacities of 8% or greater and 6%, respectively. Using RBS cuts within the parameters of AISC 358-16 resulted in the largest ductility. The moment end-plate to embedded plate connection was determined to have a significant effect on the beam stiffness.
Get full access to this article
View all available purchase options and get full access to this article.
Data Availability Statement
Some or all data, models, or code that support the findings of this study are available from the corresponding author upon reasonable request.
Acknowledgments
In-kind donations were provided by Metals Fab of Spokane, WA. Scott Lewis is thanked for his assistance with the construction and testing.
References
ACI (American Concrete Institute). 2019. Building code requirements for structural concrete and commentary. ACI 318-19. Reston, VA: ACI.
AISC. 2016a. Prequalified connections for special and intermediate steel moment frames for seismic applications. AISC/ASTM 358-16. Chicago: AISC.
AISC. 2016b. Seismic provisions for structural steel buildings. AISC/ASTM 341-16. Chicago: AISC.
AISC. 2016c. Specification for structural steel buildings. AISC/ASTM 360-16. Chicago: AISC.
ASCE. 2017. Seismic evaluation and retrofit of existing buildings. ASCE/SEI 41-17. Reston, VA: ASCE.
Chen, S. J., and T. C. Tu. 2004. “Experimental study of jumbo size reduced beam section connections using high-strength steel.” J. Struct. Eng. 130 (4): 582–587. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:4(582).
Chen, S. J., C. H. Yeh, and J. M. Chu. 1996. “Ductile steel beam-to-column connections for seismic resistance.” J. Struct. Eng. 122 (11): 1292–1299. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:11(1292).
Choi, Y., and S. Chao. 2020. “Analysis and design of double-beam coupling beams.” ACI Struct. J. 117 (5): 79–95. https://doi.org/10.14359/51725985.
Chopra, K. A. 2017. Dynamics of structures: Theory and applications to earthquake engineering. 5th ed. Hoboken, NJ: Pearson.
Engelhardt, M. D., G. T. Fry, S. Jones, M. Venti, and S. Holliday. 2000. Behavior and design of radius-cut reduced beam section connections. Sacramento, CA: Sac Joint Venture.
Engelhardt, M. D., T. Winneberger, A. J. Zekany, and T. J. Potyraj. 1998. “Experimental investigation of Dogbone moment connections.” Eng. J. 35 (4): 128–139.
Farsi, A., F. Keshavarzi, P. Pouladi, and R. Mirghaderi. 2016. “Experimental study of a replaceable steel coupling beam with an end-plate connection.” J. Constr. Steel Res. 122 (Jul): 138–150. https://doi.org/10.1016/j.jcsr.2016.03.018.
Fisher, J. M., and L. A. Kloiber. 2006. Design guide 1: Base plate and anchor rod design. 2nd ed. Chicago: AISC.
Fortney, P. J., B. M. Shahrooz, and G. A. Rassati. 2004. “The next generation of coupling beams.” In Proc., 5th Int. Conf. on Composite Construction in Steel and Construction. Reston, VA: ASCE. https://doi.org/10.1061/9780784408261.
Fortney, P. J., B. M. Shahrooz, and G. A. Rassati. 2007. “Large-scale testing of a replaceable ‘fuse’ steel coupling beam.” J. Struct. Eng. 133 (12): 1801–1807. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:12(1801).
Gong, B., and B. M. Shahrooz. 2001a. “Concrete-steel composite coupling beams. I: Component testing.” J. Struct. Eng. 127 (6): 625–631. https://doi.org/10.1061/(ASCE)0733-9445(2001)127:6(625).
Gong, B., and B. M. Shahrooz. 2001b. “Concrete-steel composite coupling beams. II: Subassembly testing and design verification.” J. Struct. Eng. 127 (6): 632–638. https://doi.org/10.1061/(ASCE)0733-9445(2001)127:6(632).
Harries, K. A., D. Mitchell, W. D. Cook, and R. G. Redwood. 1993. “Seismic response of steel beams coupling concrete walls.” J. Struct. Eng. 119 (12): 3611–3629. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:12(3611).
Harries, K. A., D. Mitchell, R. G. Redwood, and W. D. Cook. 1997. “Seismic design of coupled walls—A case for mixed construction.” Can. J. Civ. Eng. 24 (3): 448–459. https://doi.org/10.1139/l96-130.
Marcakis, K., and D. Mitchell. 1980. “Precast concrete connections with embedded steel members.” PCI J. 25 (4): 88–116. https://doi.org/10.15554/pcij.07011980.88.116.
Mattock, A. H., and G. H. Gaafar. 1982. “Strength of embedded steel sections as brackets.” ACI Struct. J. 79 (2): 83–93.
Meng, R. L., and T. M. Murray. 1997. “Seismic performance of bolted end-plate moment connections.” In Proc., AISC National Steel Construction Conf., 1–14. Chicago: AISC.
Moehle, J., Y. Bozorgnia, N. Jayaram, P. Jones, M. Rahnama, N. Shome, Z. Tuna, J. Wallace, T. Yang, and F. Zareian. 2011. Case studies of the seismic performance of tall buildings designed by alternative means. Task 12 report for tall building initiative. Washington, DC: FEMA.
Mohr, D., D. Lehman, and L. Lowes. 2007. “Performance-based design and nonlinear modeling of coupled shear walls and coupling beams.” In Proc., Structures Congress. Reston, VA: ASCE.
Motter, C. J., D. C. Fields, J. D. Hooper, R. Klemencic, and J. W. Wallace. 2017a. “Steel-reinforced concrete coupling beams. I: Testing.” J. Struct. Eng. 143 (3): 04016191. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001670.
Motter, C. J., D. C. Fields, J. D. Hooper, R. Klemencic, and J. W. Wallace. 2017b. “Steel-reinforced concrete coupling beams. II: Modeling.” J. Struct. Eng. 143 (3): 04016192. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001671.
Murray, T. M., and E. A. Sumner. 2003. Design guide 4: Extended end-plate moment connections: Seismic and wind applications. 2nd ed. Chicago: AISC.
Naish, D., A. Fry, R. Klemencic, and J. Wallace. 2013a. “Reinforced concrete coupling beams. Part I: Testing.” ACI Struct. J. 110 (6): 1057–1066.
Naish, D., A. Fry, R. Klemencic, and J. Wallace. 2013b. “Reinforced concrete coupling beams. Part II: Modeling.” ACI Struct. J. 110 (6): 1067–1075.
RCSC (Research Council on Structural Connections). 2014. Specification for structural joints using high-strength bolts. Chicago: Research Council on Structural Connections, AISC.
Shahrooz, B. M., P. J. Fortney, and K. A. Harries. 2018. “Steel coupling beams with replaceable fuse.” J. Struct. Eng. 144 (2): 04017210. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001939.
Shahrooz, B. M., M. E. Remetter, and F. Qin. 1993. “Seismic design and performance of composite coupled walls.” J. Struct. Eng. 119 (11): 3291–3309. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:11(3291).
Shen, J., T. Kitjasateanphun, and W. Srivanic. 2000. “Seismic performance of steel moment frames with reduced beam sections.” Eng. Struct. 22 (8): 968–983. https://doi.org/10.1016/S0141-0296(99)00048-6.
Sumner, E. A., and T. M. Murray. 2002. “Behavior of extended end-plate moment connections subject to cyclic loading.” J. Struct. Eng. 128 (4): 501–508. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(501).
Thompson, K. M., J. O. Jirsa, and J. E. Breen. 2006. “Behavior and capacity of headed reinforcement.” ACI Struct. J. 103 (4): 522–530.
Information & Authors
Information
Published In
Copyright
© 2022 American Society of Civil Engineers.
History
Received: Jan 10, 2022
Accepted: Jun 15, 2022
Published online: Aug 8, 2022
Published in print: Oct 1, 2022
Discussion open until: Jan 8, 2023
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.