FRP Confinement of Square Masonry Columns
Publication: Journal of Composites for Construction
Volume 13, Issue 2
Abstract
The problem of masonry columns subjected to structural deficiency under axial load was studied and reported in this paper. The results of an extensive experimental campaign are presented in order to show the behavior of columns built with clay or with calcareous blocks, commonly found in southern Italy, especially in historical buildings. Rectangular masonry columns were tested for a total of 33 specimens; uniaxial compression tests were conducted on columns taking into account the influence of several variables: different strengthening schemes (internal and/or external confinement), curvature radius of the corners, amount of fiber-reinforced polymer (FRP) reinforcement, cross-section aspect ratio, and material of masonry blocks. Materials characterization was preliminarily carried out including a mechanical test on plain masonry. For all cases the experimental results evidenced a significant increase in load carrying capacity and ductility after FRP strengthening, which identified the columns as ductile elements despite the brittle nature of the unconfined masonry. Differences in mechanical behavior, due to the geometry of the columns, to the nature of different materials, to different strengthening schemes, and to the amount of reinforcement, are presented and discussed in the paper. The calibration of design equations recently developed by Italian National Research Council, CNR was conducted to compare analytical prediction and experimental results. The same procedure was applied to calibrate an analytical model recently published, in which the existing coefficients are related only to clay. Here the model is applied to limestone for the first time. Thus, new important information is furnished to researchers and practitioners involved in structural assessment and strengthening of compressed elements in historical buildings.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This investigation was supported by project No. UNSPECIFIEDDPC-ReLUIS 2005-2008 in research line No. 8 “Innovative Materials for Vulnerability mitigation in Existing Structure.” The writers would like to acknowledge EPO Gmbh and MAPEI SpA for materials supplied in this investigation.
References
Aiello, M. A., Micelli, F., and Valente, L. (2005). “Circular masonry columns confined with FRP.” Proc., Composites in Construction 3rd Int. Conf.—Tome 1, P. Hamelin, D. Bigaud, E. Ferrier, and E. Jacquelin, eds., University of Lyon, Lyon, France, 485–492.
Aiello, M. A., Micelli, F, and Valente, L. (2007). “Structural upgrading of masonry columns by using composite reinforcements.” J. Compos. Constr., 11(6), 650–658.
American Concrete Institute (ACI). (2002). “Design and construction of externally bonded FRP systems for strengthening concrete structures.” Technical Document No. ACI 440.2R.02, Detroit.
American Concrete Institute (ACI). (2004). “Guide test methods for fiber-reinforced polymers (FRPs) for reinforcing or strengthening concrete structures.” ACI Technical Document No. 440.3R-04, Detroit.
Chaallal, O., Hassan, M., and LeBlanc, M. (2006). “Circular columns Confined with FRP: Experimental versus predictions of models and guidelines.” J. Compos. Constr., 10(1), 4–12.
Consiglo Nazionale delle Ricerche (CNR) (2004). “Guide for the design and construction of externally bonded FRP systems for strengthening of existing structures.” Technical Document No. 200/2004, Italian National Research Council, Rome.
Ente Nazionale di Unificazione (UNI). (1990). “UNI 9724–4 Materiali lapidei. Confezionamento sezioni sottili e lucide.” Italy.
Ente Nazionale di Unificazione (UNI). (2005). “UNI EN 196–1 methods of testing cement—Part 1: Determination of strength.” Italy.
Faella, C., Aiello, M. A., Nigro, E., Martinelli, E., Micelli, F., Paciello, S., and Valente, L. (2007). “Sperimentazione su pilastri in muratura confinati con FRP.” Proc., Materiali ed Approcci Innovativi per il Progetto in Zona Sismica e la Mitigazione della Vulnerabilità delle Strutture, University of Salerno, Reluis Projcet, Salerno, Italy.
Faella, C., Martinelli, E., Paciello, S., and Nigro, E. (2004). “Experimental tests and theoretical models on tuff masonry bricks and columns confined with C-FRP sheets.” Proc., IMTCR04 Int. Conf. A. Nanni and A. La Tegola, eds., Vol. 2, Liguori ed., Lecce, Italy, 343–359.
FIB TG. (2001). “Externally bonded FRP reinforcement for RC structures.” Tech. Rep. No. FIB TG 96, Lausanne, Switzerland.
Japan Society of Civil Engineers (JSCE). (2001). “Recommendations for upgrading of concrete structures with use of continuous fiber sheets.” Concrete engineering Series 41, K. Maruyama, ed., Japan.
Kog, Y. C., Ong, K. C. G., Yu, C. H., and Sreekanth, P. V. (2001). “Reinforced concrete jacketing for masonry columns with axial loads.” ACI Mater. J., 98(2), 105–115.
Krevaikas, T. D., and Triantafillou, T. (2006). “Masonry confinement with fiber-reinforced polymers.” J. Compos. Constr., 9(2), 128–135.
Micelli, F., De Lorenzis, L., and La Tegola, A. (2003). “Confinement of masonry columns with FRP bars.” Proc., Composites in Construction—3rd Int. Conf., D. Bruno, G. Spadea, and N. Swamy, eds., Cosenza, Italy, 373–378.
Information & Authors
Information
Published In
Copyright
© 2009 ASCE.
History
Received: Jan 16, 2008
Accepted: Sep 26, 2008
Published online: Apr 1, 2009
Published in print: Apr 2009
Authors
Metrics & Citations
Metrics
Citations
Download citation