Electrical Transmission and Substation Structures 2018
Keeping the Project on Schedule—A Case Study about Emergency Weld Repairs Required on a Newly Installed Vibratory Caisson
Publication: Electrical Transmission and Substation Structures 2018: Dedicated to Strengthening our Critical Infrastructure
ABSTRACT
When critical weld repairs and an overall shortening of a foundation caisson threaten to slow down construction crews on an important transmission line construction project, several activities must be quickly and effectively completed to get the issue resolved in a safe and effective manner. This paper will review the steps taken in one such instance, including: developing an overall problem statement; engineering analysis of the shortened caisson depth; organizing the site specific and project specific constraints that might impact execution of the repair; assuring appropriate and effective weld procedures to execute the field repair and ensuring qualified and experienced welder/fitters are utilized; developing an effective solution for the finish/coating repairs that would be needed following weld repairs; and identifying all quality assurance steps that will be needed to be executed throughout the entire repair process.
Get full access to this article
View all available purchase options and get full access to this chapter.
REFERENCES
ASCE (American Society of Civil Engineers). (2011) Design of Steel Transmission Pole Structures, Standard ASCE/SEI 48-11. ASCE, 1801 Alexander Bell Dr., Reston, VA
AWS (American Welding Society) (2015) Structural Welding Code - Steel, 23rd Edition, AWS D1.1/D1.1M:2015, AWS, 550 N.W. Le Jeune Road, Miami, FL
ASTM A572-07 Standard Specification for High-Strength Low-Alloy Columbium-Vanadium Structural Steel. ASTM International, West Conshohocken, PA, 2015, www.astm.org.
ASTM A780-09 Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings. ASTM International, West Conshohocken, PA, 2015, www.astm.org
ASNT (The American Society for Nondestructive Testing). SNT-TC-1A Recommended Practice No. SNT-TC-1A, Personnel Qualification and Certification in Nondestructive Testing, 2016 Edition. The American Society of Nondestructive Testing, Inc., 1711 Arlingate Lane, Columbus, OH 43228-0518, www.asnt.org.
LPILE is a product of ENSOFT Inc., 3003 West Howard Lane, Austin, TX 78728, www.ensoftinc.com.
PLS-CADD is a product of Powerline Systems, Inc., 610 N. Whitney Way, Suite 160 Madison, WI 53705, www.powline.com.
Information & Authors
Information
Published In
Electrical Transmission and Substation Structures 2018: Dedicated to Strengthening our Critical Infrastructure
Pages: 11 - 22
Editor: Michael Miller, SAE Towers
ISBN (Online): 978-0-7844-8183-7
Copyright
© 2018 American Society of Civil Engineers.
History
Published online: Nov 1, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.