Abstract
This paper reports on the third phase of a multiphase study undertaken at the American University of Beirut (AUB) to examine the effect of fiber-reinforced polymer (FRP) sheets in confining tension lap splice regions in reinforced concrete beams. Results of the first two phases showed that glass and carbon fiber-reinforced polymer (GFRP and CFRP) sheets were effective in increasing the bond strength and improving the ductility of the mode of failure of tension lap splices in high-strength concrete (HSC) beams with nominal concrete strength of 70 MPa. The experimental results of the two phases were used to propose a new FRP confinement parameter, that accounts for the bond strength contribution of FRP sheets wrapping tension lap splice regions in HSC beams. In this third phase of the AUB study, the trend of the results of phases 1 and 2 and the validity of the analytical model proposed were verified if normal-strength concrete (NSC) is used instead of HSC. Seven beams with nominal concrete strength of 27.58 MPa (4 ksi) were tested in positive bending. Each beam was designed with a tension lap splice in a constant moment region in the midspan of the beam. The main test variables were the configuration (1 strip, 2 strips, or a continuous strip) and the number of layers (1 layer or 2 layers) of the CFRP sheets wrapping the splice region. The test results demonstrated that CFRP sheets were effective in enhancing the bond strength and ductility of failure mode of tension lap splices in NSC in a very similar way to HSC. In addition, the FRP confinement index proposed earlier for HSC was proven to be valid in the case of NSC.
Get full access to this article
View all available purchase options and get full access to this article.
References
American Concrete Institute (ACI). (1996). “State-of-the-art report on fiber reinforced plastic reinforcement for concrete.” ACI 440R-96, Committee 440, Farmington Hills, Mich.
American Concrete Institute (ACI). (2002). “Guide for the design and construction of externally bonded FRP systems for strengthening con-crete structures.” ACI 440-02, Committee 440, Farmington Hills, Mich.
Darwin, D., Zuo, J., Tholen, M. L., and Idun, E. K.(1996). “Development length criteria for conventional and high relative area reinforcing bars.” ACI Struct. J., 93(3), 347–359.
Hamad, B. S., Harajli, M. H., and Joumaa, G. K.(2001). “Effect of steelfiber reinforcement on bond strength of tension lap splices in high strength concrete.” ACI Struct. J., 98(5), 638–647.
Hamad, B. S., and Najjar, S. S.(2002). “Evaluation of the role of transverse reinforcement in confining tension lap splices in high strength concrete.” Materials and Structures Journal,35, 219–228.
Hamad, B. S., Rteil, A. A., and Soudki, K. A.(2004). “Bond strength of tension lap splices in high-strength concrete beams strengthened with glass fiber reinforced polymer wraps.” J. Compos. Constr., 8(1), 14–21.
Information & Authors
Information
Published In
Copyright
Copyright © 2004 American Society of Civil Engineers.
History
Received: Jun 11, 2002
Accepted: Apr 24, 2003
Published online: May 14, 2004
Published in print: Jun 2004
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.