Measurement of Oxygen Transfer in Clean Water

most recent

Abstract

  • Prepared by the Committee on Oxygen Transfer Standards of the Special Standards Division of the Environmental & Water Resources Institute of ASCE Measurement of Oxygen Transfer in Clean Water, ASCE/EWRI 2-22, provides the latest methods for measuring the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water. This standard aims to be general enough to be applied to all clean water unsteady-state tests and specific enough to incorporate all essential procedures.

    This standard is an update of the 2006 version. Revisions to the mandatory requirements include use of the nonlinear least squares estimates for parameter fitting, the need to correct and report results to a common TSS level, and acceptance of a nitrogen gas method for deoxygenation. A new commentary provides a detailed description of a supersaturated oxygen desorption method. This method may be incorporated into a future revision of the standard as an acceptable method, pending a comparison of results with existing deoxygenation methods.

    ASCE 2-22 is meant to be used by engineers in the preparation of specifications for compliance testing by manufacturers developing performance information and is applicable to laboratory scale oxygenation devices with water volumes of a few gallons, as well as to full-scale systems with water volumes typical of those found in the activated sludge wastewater treatment process.

For selected items:
FREE
CHAPTER 1 INTRODUCTION
1–3
CHAPTER 2 SUMMARY OF THE METHODS
5–6
CHAPTER 3 ACCURACY AND LIMITATIONS
7–8
CHAPTER 4 DEFINITIONS
9–10
CHAPTER 5 APPARATUS AND METHODS
11–12
CHAPTER 6 PROCEDURE
13–18
CHAPTER 7 DATA ANALYSIS
19–20
CHAPTER 8 INTERPRETATION AND REPORTING OF RESULTS
21–22
CHAPTER 9 REPORTING
23–24
APPENDIX A GAS FLOW MEASUREMENTS
25–26
APPENDIX B POWER MEASUREMENTS
27–28
APPENDIX C POWDERED SULFITE ADDITION
29–30
APPENDIX D DISSOLVED OXYGEN PROBE CALIBRATION
31–32
APPENDIX E PREPARATION OF DATA FOR ANALYSIS
33–34
APPENDIX F CALCULATION OF C*∞20
35–36
COMMENTARY (NONMANDATORY) TO STANDARD 2-22
CHAPTER C1 INTRODUCTION
37–39
CHAPTER C2 THE HIGH PURITY OXYGEN DESORPTION METHOD
41–44
CHAPTER C5 APPARATUS AND METHODS
45–46
CHAPTER C6 PROCEDURES
47–48
CHAPTER C8 INTERPRETATION AND REPORTING OF RESULTS
49–50