Technical Papers
Oct 26, 2023

Adaptive Passive Seismic Isolation System for Mitigating the Acceleration Response of Floor-Mounted Equipment

Publication: Journal of Structural Engineering
Volume 150, Issue 1

Abstract

Protecting critical equipment in seismically excited buildings is essential to ensure functionality after an earthquake. Individual equipment or equipment sets can be seismically isolated from the building motion. Special isolators can be employed to mitigate the most severe accelerations that occur in the horizontal direction of a building. This paper presents the results of an investigation of the performance of an uncoupled bidirectional isolation system for horizontal isolation using a novel adaptive restoring force (ARF) device. The device changes the structural response transmitted to floor-mounted equipment by filtering the most intense portions of input floor acceleration histories to minimize the acceleration of the equipment and the stress demands imposed by the supporting structures. The ARF device utilizes restoring and damping elements to generate restoring forces that vary nonlinearly with displacement, resulting in a force–displacement curve with varying slopes and loading and unloading paths. The force–displacement relationship of the ARF device is characterized by high stiffness at small and large displacements, and low stiffness in between. A small-scale prototype was constructed to validate the ARF concept, and its force–displacement properties were observed for cyclic loading. A numerical model was developed that accurately predicted the relationship between the device force and displacement. The system’s performance was evaluated through numerical analysis of equipment installed on different levels of multistory buildings subjected to measured floor accelerations. The results showed that the horizontal isolation system effectively limited the transmission of the floor accelerations to the equipment. Furthermore, the results showed that the isolation system transformed the seismic acceleration profile from a high-amplitude and -frequency signal to one with a low quasi-constant amplitude and low frequency, acting as a low-pass filter under the most intense time window of the floor acceleration.

Practical Applications

Protecting critical equipment can be a significant concern for those who manage or work in facilities vulnerable to earthquakes. This study presents a new technology for horizontal seismic isolation of equipment, the adaptive restoring force device, that effectively minimizes the damaging effects of earthquakes on floor-mounted equipment in multistory buildings. The ARF device protects equipment by filtering out the most intense and destructive vibrations accompanying earthquakes, thus reducing accelerations on the equipment and its supporting structures. It transforms high-amplitude and -frequency vibrations to lower, more-constant levels. Unique to the ARF device is its adaptability to work effectively on any floor of a building, even on rooftops, while allowing considerable relative movement between the equipment and the floor. The results of this study are promising—equipment experienced reduced and nearly constant low-frequency accelerations during simulated seismic events. Although further research is required to address more complex problems, such as building torsion and vertical seismic effects, preliminary findings suggest that the ARF device offers a practical solution for preserving vital floor-mounted equipment in multistory buildings in earthquake-prone regions. This device can prove invaluable as a tangible solution for businesses, industries, and hospitals dependent on critical equipment.

Get full access to this article

View all available purchase options and get full access to this article.

Data Availability Statement

Some or all data, models, or code that support the findings of this study are available from the corresponding author upon reasonable request.

References

Bogacki, P., and L. F. Shampine. 1989. “A 3(2) pair of Runge–Kutta formulas.” Appl. Math. Lett. 2 (4): 321–325. https://doi.org/10.1016/0893-9659(89)90079-7.
Chen, M. C., et al. 2016. “Full-scale structural and nonstructural building system performance during earthquakes: Part I—Specimen description, test protocol, and structural response.” Earthquake Spectra 32 (2): 737–770. https://doi.org/10.1193/012414eqs016m.
Cheng, D. J., W.-S. Yang, J.-H. Park, T.-J. Park, S.-J. Kim, G.-H. Kim, and C.-H. Park. 2014. “Friction experiment of linear motion roller guide THK SRG25.” Int. J. Precis Eng. Manuf. 15 (3): 545–551. https://doi.org/10.1007/s12541-014-0369-y.
Chopra, A. K. 2017. Dynamics of structures: Theory and applications to earthquake engineering. 5th ed. Bloomington, MN: Pearson.
Cimellaro, G. P., A. M. Reinhorn, and M. Bruneau. 2010. “Framework for analytical quantification of disaster resilience.” Eng. Struct. 32 (11): 3639–3649. https://doi.org/10.1016/j.engstruct.2010.08.008.
Cui, S., M. Bruneau, and A. Kasalanati. 2016. “Seismic response case study of isolated floor system having special biaxial spring units.” J. Struct. Eng. 142 (12): 05016002.https://doi.org/10.1061/(ASCE)ST.1943-541X.0001596.
Harvey, P. S., Jr., and K. C. Kelly. 2016. “A review of rolling-type seismic isolation: Historical development and future directions.” Eng. Struct. 125 (Oct): 521–531. https://doi.org/10.1016/j.engstruct.2016.07.031.
Hong, X. J., S. Zhu, and Y.-L. Xu. 2010. “Three-dimensional vibration control of high-tech facilities against earthquakes and microvibration using hybrid platform.” Earthquake Eng. Struct. Dyn. 39 (6): 615–634. https://doi.org/https://doi.org/10.1002/eqe.960.
Ismail, M., J. Rodellar, and F. Ikhouane. 2009. “An innovative isolation bearing for motion-sensitive equipment.” J. Sound Vib. 326 (3): 503–521. https://doi.org/10.1016/j.jsv.2009.06.022.
Kasalanati, A., T. Ng, and K. Friskel. 2017. “Seismic isolation of sensitive equipment.” In Proc., 16th World Conf. Earthquake Engineering. Tokyo: International Association for for Earthquake Engineering.
Kashiwazaki, A., T. Shimada, T. Fujiwaka, and S. Moro. 2003. “Study on 3-dimensional base isolation system applying to new type power plant reactor (Hydraulic 3-dimensional base isolation system: No.1)” In Proc., Transactions 17th Int. Conf. on Structural Mechanics in Reactor Technology, 1–8. Raleigh, NC: International Association for Structural Mechanics in Reactor Technology.
Mallat, S. 2008. “A wavelet tour of signal processing: The sparse way.” In A wavelet tour of signal processing: The sparse way. Cambridge, MA: Academic Press. https://doi.org/10.1016/B978-0-12-374370-1.X0001-8.
National Research Council. 2011. National earthquake resilience: Research, implementation, and outreach. Washington, DC: The National Academies Press. https://doi.org/10.17226/13092.
Uriu, M., M. Yamamoto, K. Shinzawa, T. Yamazaki, N. Tokuda, A. Kashiwazaki, M. Iwama, S. Matumoto, J. Yokozawa, and A. Hara. 1993. “Three-dimensional seismic isolation floor system using air spring and its installation into a nuclear facility.” In Proc., Transactions of the 12th Int. Conf. on Structural Mechanics in Reactor Technology, 363–368. Raleigh, NC: International Association for Structural Mechanics in Reactor Technology.

Information & Authors

Information

Published In

Go to Journal of Structural Engineering
Journal of Structural Engineering
Volume 150Issue 1January 2024

History

Received: Apr 13, 2023
Accepted: Aug 29, 2023
Published online: Oct 26, 2023
Published in print: Jan 1, 2024
Discussion open until: Mar 26, 2024

Permissions

Request permissions for this article.

Authors

Affiliations

Associate Professor, Dept. of Civil and Environmental Engineering, Ohio Univ., Athens, OH 45701 (corresponding author). ORCID: https://orcid.org/0000-0003-3459-4073. Email: [email protected]
Claudia Marin-Artieda, Ph.D., M.ASCE
Professor, Dept. of Civil and Environmental Engineering, Howard Univ., Washington, DC 20059.
Keanu McElroy
Undergraduate Student, Dept. of Civil and Environmental Engineering, Ohio Univ., Athens, OH 45701.

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share