Experimental Performance Assessment of Large-Scale Polyurethane-Enhanced Damage-Resistant Bridge Columns with Energy Dissipation Links. I: Overview and Damage Assessment
Publication: Journal of Structural Engineering
Volume 147, Issue 10
Abstract
This paper, which is the first of two companion papers, investigates the performance of a novel bridge column design, termed polyurethane (PU)-enhanced rocking column with energy dissipation (ED) links, through a large-scale testing program. The proposed column design offers explicit damage control via damage-resistant end segments made of PU, ED and flexural strength/stiffness through ED links, and self-centering through internal unbonded post-tensioning. The PU segments have high deformability, allowing large lateral column deformations with negligible damage. The ED links are in the form of buckling-restrained bars made of high-performance steel and offer hysteretic damping and flexural stiffness and strength to reduce the seismically induced displacement demands. The experimental program included cyclic testing, at various loading rates, of large-scale (approximately 1:2.5) PU-enhanced cantilever rocking columns with two designs for the PU segment: (1) solid PU segment, and (2) axisymmetrically bilayered segment with an exterior PU layer to withstand seismic loads and an internal reinforced concrete core to sustain long-term axial service loads and provide resistance against creep. The specimens are subjected to displacement-controlled lateral cyclic loading of increasing amplitude (exceeding a 10% drift ratio) at several drift ratio rates (up to ). A tested column is repaired via ED link release and retightening to demonstrate their rapid reparability characteristics and are retested to demonstrate the recovery of the original column properties. While ED link release and retightening (i.e., ED link reuse) is adopted in this study, because the yielding of the ED links was small as verified in the second companion paper by the practically identical response of the original and retrofitted column, it can be deduced that ED link replacement (i.e., use of new/pristine ED links) would also restore the original column properties. A rocking-only precast concrete column is also tested under the same loading protocols to serve as reference for comparisons. This first companion paper outlines the experimental program, quantifies the observed damage of the proposed column design for a range of seismic hazard intensities and compares it with that of the rocking-only column, and validates the capability of ED link release and retightening (and, by extension, ED link replacement) as a repair method that recovers the damage resistance/avoidance properties of the original system. Compared to conventional RC rocking columns, the proposed column design demonstrated significantly higher resistance against damage in terms of concrete spalling and crushing.
Get full access to this article
View all available purchase options and get full access to this article.
Data Availability Statement
All data used in this study appear in the published article.
Acknowledgments
The authors would like to acknowledge BASF (2016), particularly Mr. Patrick Webster and Mrs. Staci Wegener, for donating polyurethane solutions and samples and for providing guidance on specimen preparation.
References
AASHTO. 2014. AASHTO LRFD bridge design specifications, 7th ed. Washington, DC: AASHTO.
Abdelkarim, O. I., M. A. ElGawady, A. Gheni, S. Anumolu, and M. Abdulazeez. 2016. “Seismic performance of innovative hollow-core FRP–concrete–steel bridge columns.” J. Bridge Eng. 22 (2): 04016120. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000985.
Ameli, M., and C. P. Pantelides. 2017. “Seismic analysis of precast concrete bridge columns connected with grouted splice sleeve connectors.” J. Struct. Eng. 143 (2): 04016176. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001678.
Ameli, M., J. E. Parks, D. N. Brown, and C. P. Pantelides. 2015. “Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction.” PCI J. 60 (2): 80–103. https://doi.org/10.15554/pcij.03012015.80.103.
Ameli, M. J., D. N. Brown, J. E. Parks, and C. P. Pantelides. 2016. “Seismic column-to-footing connections using grouted splice sleeves.” ACI Struct. J. 113 (5): 1021–1030. https://doi.org/10.14359/51688755.
ASTM. 2010. Standard test method for compressive properties of rigid plastics. West Conshohocken, PA: ASTM.
ASTM. 2013. Standard specification for packaged dry, hydraulic-cement grout (nonshrink). West Conshohocken, PA: ASTM.
ASTM. 2014. Standard specification for deformed and plain carbon-steel bars for concrete reinforcement. West Conshohocken, PA: ASTM.
ASTM. 2018. Standard specification for low-relaxation, seven-wire steel strand for prestressed concrete. West Conshohocken, PA: ASTM.
ASTM. 2019. Standard specification for carbon structural steel. West Conshohocken, PA: ASTM.
BASF. 2016. “Industrial chemical manufacturer.” Accessed February 15, 2014. https://www.basf.com/us/en.html.
Billington, S. L., and J. Yoon. 2004. “Cyclic response of unbonded posttensioned precast columns with ductile fiber-reinforced concrete.” J. Bridge Eng. 9 (4): 353–363. https://doi.org/10.1061/(ASCE)1084-0702(2004)9:4(353).
Brenes, F. J., S. L. Wood, and M. E. Kreger. 2006. Anchorage requirements for grouted vertical-duct connectors in precast bent cap systems: A summary. Austin, TX: Center For Transportation Research.
CALTRANS. 2006. Caltrans seismic design criteria—Version 1.4. Sacramento, CA: California DOT.
Chou, C. C., and Y. C. Chen. 2006. “Cyclic tests of post-tensioned precast CFT segmental bridge columns with unbonded strands.” Earthqukae Eng. Struct. Dyn. 35 (2): 159–175. https://doi.org/10.1002/eqe.512.
Davis, P. M. 2011. Unbonded pre-tensioned columns for bridges in seismic regions. Washington, DC: Univ. of Washington.
ElGawady, M. A., and H. M. Dawood. 2012. “Analysis of segmental piers consisted of concrete filled FRP tubes.” Eng. Struct. 38 (1): 142–152. https://doi.org/10.1016/j.engstruct.2012.01.001.
Finnsson, G. 2013. Unbonded pre-tensioned bridge columns with hybrid fiber-reinforced concrete shells. Washington, DC: Univ. of Washington.
Guerrini, G., J. Restrepo, and M. Schoettler. 2017. “Self-centering, low-damage, precast post-tensioned columns for accelerated bridge construction in seismic regions.” In Proc., 16th World Conf. on Earthquake Engineering. Oakland, CA: Earthquake Engineering Research Institute.
Guerrini, G., J. I. Restrepo, M. Massari, and A. Vervelidis. 2015. “Seismic behavior of posttensioned self-centering precast concrete dual-shell steel columns.” J. Struct. Eng. 141 (4): 04014115. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001054.
Haber, Z. B., M. S. Saiidi, and D. H. Sanders. 2014. “Seismic performance of precast columns with mechanically spliced column-footing connections.” ACI Struct. J. 111 (3): 639. https://doi.org/10.14359/51686624.
Hewes, J. 2007. “Seismic tests on precast segmental concrete columns with unbonded tendons.” Bridge Struct. 3 (3–4): 215–227. https://doi.org/10.1080/15732480701520352.
Hewes, J. T., and M. N. Priestley. 2002. Seismic design and performance of precast concrete segmental bridge columns. San Diego: Univ. of California.
Ichikawa, S., H. Matsuzaki, A. Moustafa, M. A. ElGawady, and K. Kawashima. 2016. “Seismic-resistant bridge columns with ultrahigh-performance concrete segments.” J. Bridge Eng. 21 (9): 04016049. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000898.
Kaviani, P., F. Zareian, and E. Taciroglu. 2014. Performance-based seismic assessment of skewed bridges. Berkeley, CA: Pacific Earthquake Engineering Research Center.
Mander, J. B., and C. T. Cheng. 1997. Seismic design of bridge piers based on damage avoidance design (NCEER-97-0014). Buffalo, NY: National Center for Earthquake Engineering Research.
Marriott, D. 2009. “The development of high-performance post-tensioned rocking systems for the seismic design of structures.” Ph.D. dissertation, Dept. of Civil and Natural Resources Engineering, Univ. of Canterbury.
Marriott, D., S. Pampanin, and A. Palermo. 2009. “Quasi-static and pseudo-dynamic testing of unbonded post-tensioned rocking bridge piers with external replaceable dissipaters.” Earthquake Eng. Struct. Dyn. 38 (3): 331–354. https://doi.org/10.1002/eqe.857.
Matsumoto, E. E., M. C. Waggoner, M. E. Kreger, J. Vogel, and L. Wolf. 2008. “Development of a precast concrete bent-cap system.” PCI J. 53 (3): 74–99. https://doi.org/10.15554/pcij.05012008.74.99.
Matsumoto, E. E., M. C. Waggoner, G. Sumen, M. E. Kreger, S. L. Wood, and J. E. Breen. 2001. Development of a precast bent cap system. Austin, TX: Center for Transportation Research, Univ. of Texas at Austin.
McKenna, F., and G. L. Fenves. 2001. The OpenSees command language manual. Berkeley, CA: Univ. of California.
Morgen, B., and Y. Kurama. 2004. “A friction damper for post-tensioned precast concrete beam-to-column joints.” PCI J. 49 (4): 112–133. https://doi.org/10.15554/pcij.07012004.112.133.
Motaref, S., M. S. Saiidi, and D. Sanders. 2013. “Shake table studies of energy-dissipating segmental bridge columns.” J. Bridge Eng. 19 (2): 186–199. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000518.
Moustafa, A., and M. A. ElGawady. 2017. Seismic behavior of a damage-resistant segmental bridge column with external energy dissipaters. Washington, DC: Transportation Research Board.
Moustafa, A., A. Gheni, and M. A. ElGawady. 2017. “Shaking-table testing of high energy–dissipating rubberized concrete columns.” J. Bridge Eng. 22 (8): 04017042. https://doi.org/10.1061/(ASCE)BE.1943-5592.0001077.
Nakashoji, B. A. 2014. Seismic performance of square nickel-titanium reinforced ECC columns with headed couplers. Reno, NV: Univ. of Nevada.
Nikoukalam, M., and P. Sideris. 2017. “Resilient bridge rocking columns with polyurethane damage-resistant end segments and replaceable energy-dissipating links.” J. Bridge Eng. 22 (10): 04017064. https://doi.org/10.1061/(ASCE)BE.1943-5592.0001069.
Nikoukalam, M., and P. Sideris. 2019. “Experimental characterization and constitutive modeling of polyurethanes for structural applications, accounting for damage, hysteresis, loading rate and long term effects.” Eng. Struct. 198 (3): 109462. https://doi.org/10.1016/j.engstruct.2019.109462.
Nikoukalam, M. T. 2019. “Seismically resilient bridge columns with polyurethane-enhanced damage-resistant (DR) joints and replaceable energy dissipating (ED) links.” Ph.D. dissertation, Dept. of Civil and Environmental Engineering, Texas A&M Univ.
Nikoukalam, M. T., and P. Sideris. 2016. “Low-damage posttensioned segmental bridge columns with flexible end joints for seismic accelerated bridge construction.” Transp. Res. Rec. 2592 (1): 151–161. https://doi.org/10.3141/2592-17.
Nikoukalam, M. T., and P. Sideris. 2021. “Experimental performance assessment of large-scale polyurethane-enhanced damage-resistant bridge columns with energy dissipation links. II: Quantitative results.” J. Struct. Eng. 147 (10): 04021156. https://doi.org/10.1061/(ASCE)ST.1943-541X.0003079.
Ou, Y. C., M. Chiewanichakorn, A. J. Aref, and G. C. Lee. 2007. “Seismic performance of segmental precast unbonded posttensioned concrete bridge columns.” J. Struct. Eng. 133 (11): 1636–1647. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:11(1636).
Ou, Y. C., M. S. Tsai, K. C. Chang, and G. C. Lee. 2010. “Cyclic behavior of precast segmental concrete bridge columns with high performance or conventional steel reinforcing bars as energy dissipation bars.” Earthquake Eng. Struct. Dyn. 39 (11): 1181–1198. https://doi.org/10.1002/eqe.986.
Ou, Y.-C., Y. Oktavianus, and M.-S. Tsai. 2013. “An emulative precast segmental concrete bridge column for seismic regions.” Earthquake Spectra 29 (4): 1441–1457. https://doi.org/10.1193/082511EQS205M.
Ou, Y.-C., P.-H. Wang, M.-S. Tsai, K.-C. Chang, and G. C. Lee. 2009. “Large-scale experimental study of precast segmental unbonded posttensioned concrete bridge columns for seismic regions.”J. Struct. Eng. 136 (3): 255–264. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000110.
Panagiotou, M., W. Trono, G. Jen, P. Kumar, and C. P. Ostertag. 2014. “Experimental seismic response of hybrid fiber-reinforced concrete bridge columns with novel longitudinal reinforcement detailing.” J. Bridge Eng. 20 (7): 04014090. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000684.
Pang, J. B., M. O. Eberhard, and J. F. Stanton. 2010. “Large-bar connection for precast bridge bents in seismic regions.” J. Bridge Eng. 15 (3): 231–239. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000081.
Pantelides, C. P., M. J. Ameli, J. E. Parks, and D. N. Brown. 2014. Seismic evaluation of grouted splice sleeve connections for precast RC bridge piers in ABC. Salt Lake City, Utah: Univ. of Utah.
Restrepo, J. I., M. J. Tobolski, and E. E. Matsumoto. 2011. NCHRP Report 681: Development of a precast bent cap system for seismic regions. Washington, DC: NCHRP.
Roh, H., and A. M. Reinhorn. 2010. “Hysteretic behavior of precast segmental bridge piers with superelastic shape memory alloy bars.” Eng. Struct. 32 (10): 3394–3403. https://doi.org/10.1016/j.engstruct.2010.07.013.
Salehi, M., P. Sideris, and A. B. Liel. 2017. “Numerical simulation of hybrid sliding-rocking columns subjected to earthquake excitation.” J. Struct. Eng. 143 (11): 04017149. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001878.
Sideris, P. 2012. “Seismic analysis and design of precast concrete segmental bridges.” Ph.D. dissertation, Dept. of Civil, Structural and Environmental Engineering, State Univ. of New York at Buffalo.
Sideris, P., A. J. Aref, and A. Filiatrault. 2014. “Large-scale seismic testing of a hybrid sliding-rocking post-tensioned segmental bridge system.”J. Struct. Eng. 140 (6): 04014025. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000961.
Sideris, P., A. J. Aref, and A. Filiatrault. 2015. “Experimental seismic performance of a hybrid sliding-rocking bridge for various specimen configurations and seismic loading conditions.” J. Bridge Eng. 20 (11): 04015009. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000742.
Steuck, K. P., M. O. Eberhard, and J. F. Stanton. 2009. “Anchorage of large-diameter reinforcing bars in ducts.” ACI Struct. J. 106 (4): 506.
Tazarv, M., and M. S. Saiidi. 2015a. “Low-damage precast columns for accelerated bridge construction in high seismic zones.”J. Bridge Eng. 21 (3): 04015056. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000806.
Tazarv, M., and M. S. Saiidi. 2015b. “UHPC-filled duct connections for accelerated bridge construction of RC columns in high seismic zones.” Eng. Struct. 99 (5): 413–422. https://doi.org/10.1016/j.engstruct.2015.05.018.
Tazarv, M., and M. S. Saiidi. 2016. “Seismic design of bridge columns incorporating mechanical bar splices in plastic hinge regions.” Eng. Struct. 124 (4): 507–520. https://doi.org/10.1016/j.engstruct.2016.06.041.
Thonstad, T., I. M. Mantawy, J. F. Stanton, M. O. Eberhard, and D. H. Sanders. 2016. “Shaking table performance of a new bridge system with pretensioned rocking columns.” J. Bridge Eng. 21 (4): 04015079. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000867.
Trono, W., G. Jen, M. Panagiotou, M. Schoettler, and C. P. Ostertag. 2014. “Seismic response of a damage-resistant recentering posttensioned-HYFRC bridge column.” J. Bridge Eng. 20 (7): 04014096. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000692.
USGS. 2018. “US seismic design maps.” Accessed September 10, 2018. https://earthquake.usgs.gov/hazards/designmaps/usdesign.php.
Varela, S., and M. Saiidi. 2014. “Dynamic performance of novel bridge columns with superelastic CuAlMn shape memory alloy and ECC.” Int. J. Bridge Eng. 2 (3): 29–58.
Varela, S., and M. S. Saiidi. 2017. “Experimental study on seismically resilient 2-span bridge models designed for disassembly.”J. Earthquake Eng. 23 (1): 72–111. https://doi.org/10.1080/13632469.2017.1309724.
Wang, J. C., Y. C. Ou, K. C. Chang, and G. C. Lee. 2008. “Large-scale seismic tests of tall concrete bridge columns with precast segmental construction.” Earthquake Eng. Struct. Dyn. 37 (12): 1449–1465. https://doi.org/10.1002/eqe.824.
Yamashita, R., and D. H. Sanders. 2009. “Seismic performance of precast unbonded prestressed concrete columns.” ACI Struct. J. 106 (6): 821–830.
Information & Authors
Information
Published In
Copyright
© 2021 American Society of Civil Engineers.
History
Received: Feb 20, 2020
Accepted: Mar 22, 2021
Published online: Aug 4, 2021
Published in print: Oct 1, 2021
Discussion open until: Jan 4, 2022
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.
Cited by
- Ruijun Zhang, Tong Guo, Aiqun Li, T. Y. Yang, Shaking Table Test and Numerical Analysis of a Precast Frame Structure with Replaceable Box Connectors, Journal of Structural Engineering, 10.1061/JSENDH.STENG-13398, 150, 12, (2024).
- Keita Uemura, Jun Shirai, Yoshikazu Takahashi, Development of Aseismic Column with Self-Centering Capacity Only during Restoration, Journal of Structural Engineering, 10.1061/JSENDH.STENG-12949, 150, 10, (2024).
- Rong Fang, Wenxue Zhang, Guowei Zhang, Chiyu Jiao, Experimental and Numerical Study on the Seismic Performance of Self-Centering Isolated Piers, Journal of Bridge Engineering, 10.1061/JBENF2.BEENG-6659, 29, 10, (2024).
- Yu Shen, Fabio Freddi, Yongxing Li, Jianzhong Li, Enhanced Strategies for Seismic Resilient Posttensioned Reinforced Concrete Bridge Piers: Experimental Tests and Numerical Simulations, Journal of Structural Engineering, 10.1061/JSENDH.STENG-11831, 149, 3, (2023).
- Anas Issa, Navid Rahgozar, M. Shahria Alam, Experimental investigation and seismic analysis of a novel self-centering piston-based bracing archetype with polyurethane cores, Engineering Structures, 10.1016/j.engstruct.2023.115735, 283, (115735), (2023).
- Mohammad T. Nikoukalam, Petros Sideris, Experimental Performance Assessment of Large-Scale Polyurethane-Enhanced Damage-Resistant Bridge Columns with Energy Dissipation Links. II: Quantitative Results, Journal of Structural Engineering, 10.1061/(ASCE)ST.1943-541X.0003079, 147, 10, (2021).