Abstract
Large-scale tests of steel gravity framing systems (SGFSs) have shown that the connections are critical to the system integrity when a column suffers damage that compromises its ability to carry gravity loads. When supporting columns were removed, the SGFSs redistributed gravity loads through the development of an alternate load path in a sustained tensile configuration resulting from large vertical deflections. The ability of the system to sustain such an alternate load path depends on the capacity of the gravity connections to remain intact after undergoing large rotation and axial extension demands for which they were not designed. This study experimentally evaluates the performance of steel bolted angle connections subjected to loading consistent with interior column removal. The characteristic connection behaviors are described and the performance of multiple connection configurations are compared in terms of their peak resistances and deformation capacities.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by the American Institute of Steel Construction (AISC) and the National Science Foundation under Grant No. CMMI-1000926. The steel wide flange sections used in the experiments were donated by AISC. Any opinions, findings, conclusions, and recommendations are those of the authors, and do not necessarily reflect the views of the sponsors.
Disclaimer
Certain commercial entities, equipment, products, or materials are identified in this document in order to describe a procedure or concept adequately. Such identification is not intended to imply recommendation, endorsement, or implication that the entities, products, materials, or equipment are necessarily the best available for the purpose.
References
AISC. (2011). Steel construction manual, 14 Ed., Chicago.
Astaneh-Asl, A., et al. (2001a) “Use of catenary cables to prevent progressive collapse of buildings.”, Univ. of California at Berkeley, Dept. of Civil and Environmental Engineering, Berkeley, CA.
Astaneh-Asl, A., Jones, B., Zhao, Y., and Hwa, R. (2001b). “Progressive collapse resistance of steel building floors.”, Univ. of California at Berkeley, Dept. of Civil and Environmental Engineering, Berkeley, CA.
FEMA. (2000). “State of the art report on systems performance of steel moment resisting frames subject to earthquake ground shaking.”, Washington, DC.
Foley, C. M., Martin, K., and Schneeman, C. (2006). “Robustness in structural steel framing systems.”, Marquette Univ., Chicago.
Garlock, M. M., Ricles, J. M., and Sause, R. (2003). “Cyclic load tests and analysis of bolted top-and-seat angle connections.” J. Struct. Eng., 1615–1625.
Guravich, S. J., and Dawe, J. L. (2006). “Simple beam connections in combined shear and tension.” Can. J. Civ. Eng., 33(4), 357–372.
Jahromi, H. Z., et al. (2012). “Robustness assessment of building structures under explosion.” Buildings, 2(4), 497–518.
Johnson, E. S., Weigand, J. M., Francisco, T., Fahnestock, L. A., Liu, J., and Berman, J. W. (2014). “Large-scale experimental evaluation of the structural integrity of a composite steel and concrete building floor system.” ASCE/SEI Structures Congress, ASCE, Reston, VA.
Oosterhof, S. A., and Driver, R. G. (2012). “Performance of steel shear connections under combined moment, shear, and tension.” ASCE/SEI Structures Congress, ASCE, Reston, VA, 146–157.
Sadek, F., El-Tawil, S., and Lew, H. S. (2008). “Robustness of composite floor systems with shear connections: Modeling, simulation, and evaluation.” J. Struct. Eng., 1717–1725.
Shen, J., and Astaneh-Asl, A. (1999). “Hysteresis behavior of bolted-angle connections.” J. Constr. Steel Res., 51(3), 201–218.
UFC (Unified Facilities Criteria). (2009). “Design of buildings to resist progressive collapse.” United States Dept. of Defense, Washington, DC.
USGSA (Unified States General Services Administration). (2003). “Progressive collapse analysis and design guidelines for new federal office buildings and major modernization projects.” United States General Services Administration, Washington, DC.
Weigand, J. M. (2014). “The integrity of steel gravity framing system connections subjected to column removal loading.” Ph.D. dissertation, Univ. of Washington, Seattle.
Weigand, J. M., and Berman, J. W. (2014). “Integrity of steel single plate shear connections subjected to simulated column removal.” J. Struct. Eng., 04013114.
Weigand, J. M., Meissner, J. E., Francisco, T., Berman, J. W., Fahnestock, L. A., and Liu, J. (2012). “Testing the integrity of steel gravity frames subjected to large vertical deflections: Components.” ASCE/SEI Structures Congress, ASCE, Reston, VA.
Yang, B., and Tan, K. H. (2013). “Experimental tests of different types of bolted steel beam-column joints under a central-column-removal scenario.” Eng. Struct., 54, 112–130.
Information & Authors
Information
Published In
Copyright
© 2015 American Society of Civil Engineers.
History
Received: Jan 29, 2015
Accepted: Aug 28, 2015
Published online: Dec 8, 2015
Published in print: Mar 1, 2016
Discussion open until: May 8, 2016
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.