Performance of Three-Dimensional Reinforced Concrete Beam-Column Substructures under Loss of a Corner Column Scenario
Publication: Journal of Structural Engineering
Volume 139, Issue 4
Abstract
The vulnerability of conventional RC structures to structural failure caused by the loss of corner columns has been emphasized over the past years. However, the lack of experimental tests has led to a gap in the knowledge for the design of RC building structures to mitigate the likelihood of progressive collapse caused by losing a ground corner column. Seven one-third scale RC beam-column substructures were tested to investigate their performance. The variables selected for the test specimens included beam transverse reinforcement ratios, type of design detailing (nonseismic or seismic), and beam span aspect ratios. Shear failure was observed to have occurred in the corner joint, and a plastic hinge was formed at the beam end near the fixed support in the nonseismic detailed specimens. However, plastic hinges were also formed in the beam end near to the corner joint for the seismically detailed specimen. Vierendeel action was identified as the major load redistribution mechanism before severe failure occurred in the corner joint, but a cantilever beam redistribution mechanism dominated after the corner joint suffered severe damage. The test results were compared with the Department of Defense design guidelines to highlight the deficiencies of the recently updated guidelines.
Get full access to this article
View all available purchase options and get full access to this article.
References
ABAQUS 6.7 [Computer software]. Springer, NY, Dassault Systemes.
American Concrete Institute (ACI). (2008). “Building code requirements for structural concrete and commentary.” ACI 318-08, 318R-08, Farmington Hills, MI.
ASCE. (2006). “Seismic rehabilitation of existing buildings.” ASCE-41, Reston, VA.
ASCE. (2010). “Minimum design loads for buildings and other structures.” SEI 7, Reston, VA.
Department of Defense (DoD). (2005). “Design of building to resist progressive collapse.” UFC 4-023-03, Washington, DC.
Department of Defense (DoD). (2009). “Design of building to resist progressive collapse.” UFC 4-023-03, Washington, DC.
General Services Administration (GSA). (2003). Progressive collapse analysis and design guidelines for new federal office buildings and major modernization projects, U.S. General Services Administration, Washington, DC.
Kai, Q. (2012). “Experimental and analytical study of reinforced concrete substructures subjected to a loss of ground corner column scenario.” Ph.D. dissertation, Nanyang Technological Univ., Singapore.
Kai, Q., and Li, B. (2012a). “Experimental and analytical assessment on RC interior beam-column subassemblages for progressive collapse.” J. Perform. Constr. Facil., 26(5), 576–589.
Kai, Q., and Li, B. (2012b). “Dynamic performance of RC beam-column substructures under the scenario of the loss of a corner column-experimental results.” Eng. Struct., 42, 154–167.
Kai, Q., and Li, B. (2012c). “Slab effects on the response of reinforced concrete substructures after the loss of a corner column.” ACI Struct. J., 109(6), 845–855.
Marchand, K. A., McKay, A. E., and Stevens, D. J. (2009). “ Development and application of linear and non-linear static approaches in UFC 4-023-03.” Proc., Structures Congress 2009, ASCE, Reston, VA.
Mohamed, O. A. (2009). “Assessment of progressive collapse potential in corner floor panels of reinforced concrete buildings.” Eng. Struct., 31(3), 749–757.
Orton, S., Jirsa, J. O., and Bayrak, O. (2009). “Carbon fiber-reinforced polymer for continuity in existing reinforced concrete buildings vulnerable to collapse.” ACI Struct. J., 106(5), 608–616.
Sasani, M. (2008). “Response of a reinforced concrete infilled-frame structure to removal of two adjacent columns.” Eng. Struct., 30(9), 2478–2491.
Sasani, M., Bazan, M., and Sagiroglu, S. (2007). “Experimental and analytical progressive collapse evaluation of actual reinforced concrete structure.” ACI Struct. J., 104(6), 731–739.
Sasani, M., and Sagiroglu, S. (2008). “Progressive collapse resistance of Hotel San Diego.” J. Struct. Eng., 134(3), 478–488.
Singapore Standard. (1999). “Structural use of concrete, part 1. Code of practice for design and construction.” CP-65, Singapore.
Stevens, D. J., Marchand, K. A., and McKay, A. E. (2009). “Revision of the tie force and alternate path approaches in the DoD progressive collapse design requirements.” Proc., Structures Congress 2009, ASCE, Reston, VA.
Su, Y. P., Tian, Y., and Song, X. S. (2010). “Progressive collapse resistance of axially-restrained frame beams.” ACI Struct. J., 106(5), 600–607.
Yap, S. L., and Li, B. (2011). “Experimental investigation of RC exterior beam-column sub-assemblages for progressive collapse.” ACI Struct. J., 108(5), 542–552.
Yi, W., He, Q., Xiao, Y., and Kunnath, S. K. (2008). “Experimental study on progressive collapse-resistant behavior of reinforced concrete frame structures.” ACI Struct. J., 105(4), 433–439.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: May 18, 2011
Accepted: Jul 20, 2012
Published online: Aug 10, 2012
Published in print: Apr 1, 2013
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.