Preliminary Analysis of Direct and Indirect Heat Rejection Systems for a Small Brayton Cycle Using an Existing Natural Draft Dry Cooling Tower
Publication: Journal of Energy Engineering
Volume 144, Issue 2
Abstract
The supercritical carbon dioxide () Brayton cycle has been the focus of much research in recent years because of its high efficiency and compactness. One of the key issues is the heat rejection of about half heat addition to the cycle, which needs a strong and reliable cooling system. In this paper, indirect and direct cooling systems using a 20-m natural draft dry cooling tower (NDDCT) were proposed and investigated. One-dimensional models for these two cooling systems were selected based on the experimental data of the cooling tower. The effects of the ambient temperature on the heat rejection rate and outlet temperature for indirect and direct cooling systems were investigated, respectively. The results show that the optimal values of the water mass flow rate can be found in the indirect cooling system, and several optimal values are obtained under different ambient temperatures. Under the same operation temperature, the overall cooling performance of the direct cooling system is better than the indirect system, especially under low ambient temperature conditions. Under 15°C ambient temperature, the exergy efficiency of the direct cooling system is greater than that of the indirect cooling system (). The results of this work illustrate that the direct cooling system is more appropriate for the Gatton cooling tower and also provide some references for the dry cooling system design for small-scale cycles in the future.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was performed as a part of the National Key Research and Development Program of China (No. 2016YFB0600100). The authors Xurong Wang and Xiaoxiao Li would like to acknowledge the China Scholarship Council (CSC) for the financial support.
References
Cengel, Y., and Boles, M. (2011). Thermodynamics: An engineering approach, Vol. 3, McGraw-Hill, New York.
Conboy, T., Carlson, M., and Rochau, G. (2015). “Dry-cooled supercritical CO2 power for advanced nuclear reactors.” J. Eng. Gas Turbines Power, 137(1), 012901.
Dostal, V. (2004). “A supercritical carbon dioxide cycle for next generation nuclear reactors.” Ph.D. thesis, Massachusetts Institute of Technology, Cambridge, MA.
Frank, P. I., and David, P. D. (1996). Introduction to heat transfer, Wiley, Hoboken, NJ.
Gnielinski, V. (1976). “New equations for heat and mass transfer in turbulent pipe and channel flow.” Int. Chem. Eng., 16(2), 359–368.
Guo, J. (2016). “Design analysis of supercritical carbon dioxide recuperator.” Appl. Energy, 164, 21–27.
Haaland, S. E. (1983). “Simple and explicit formulas for the friction factor in turbulent pipe flow.” J. Fluids Eng., 105(1), 89–90.
Hooman, K. (2010). “Dry cooling towers as condensers for geothermal power plants.” Int. Commun. Heat Mass Transfer, 37(9), 1215–1220.
Kroger, D. G. (2004). Air-cooled heat exchangers and cooling towers, Vol. 1, Penn Well Books, Houston.
Lemmon, E., Huber, M., and McLinden, M. (2013). “NIST standard reference database 23 REFPROP ver. 9.1.” National Institute of Standards and Technology, Boulder, CO.
Li, H., Wang, M., Wang, J., and Dai, Y. (2016a). “Exergoeconomic analysis and optimization of a supercritical CO2 cycle coupled with a Kalina cycle.” J. Energy Eng., 04016055.
Li, X.Duniam, S., Gurgenci, H., Guan, Z., and Veeraragavan, A. (2017a). “Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant.” Appl. Energy, 193, 15–27.
Li, X., Guan, Z., Gurgenci, H., Lu, Y., and He, S. (2016b). “Simulation of the UQ Gatton natural draft dry cooling tower.” Appl. Therm. Eng., 105, 1013–1020.
Li, X., Xia, L., Gurgenci, H., and Guan, Z. (2017b). “Performance enhancement for the natural draft dry cooling tower under crosswind condition by optimizing the water distribution.” Int. J. Heat Mass Transfer, 107, 271–280.
Lu, Y. (2015). “Small natural draft dry cooling towers for renewable power plants.” Ph.D. thesis, Univ. of Queensland, St. Lucia, QLD, Australia.
Lu, Y., Guan, Z., Gurgenci, H., Hooman, K., He, S., and Bharathan, D. (2015). “Experimental study of crosswind effects on the performance of small cylindrical natural draft dry cooling towers.” Energy Convers. Manage., 91, 238–248.
Lu, Y., Guan, Z., Gurgenci, H., and Zou, Z. (2013). “Windbreak walls reverse the negative effect of crosswind in short natural draft dry cooling towers into a performance enhancement.” Int. J. Heat Mass Transfer, 63, 162–170.
Lu, Y., Gurgenci, H., Guan, Z., and He, S. (2014). “The influence of windbreak wall orientation on the cooling performance of small natural draft dry cooling towers.” Int. J. Heat Mass Transfer, 79, 1059–1069.
MATLAB [Computer software]. MathWorks, Inc., Natick, MA.
Najjar, Y. S., and Sadeq, J. (2016). “Modeling and simulation of solar thermal power system using parabolic trough collector.” J. Energy Eng., 04016056.
Nwosu, P., Nurick, A., and Akinlabi, E. (2016). “Thermodynamic optimization tools for power tracking in a multistage concentrated solar power Rankine plant.” J. Energy Eng., 04016031.
Odabaee, M., Shanechi, M., Guan, Z., and Hooman, K. (2015). “Comparison of direct and indirect cooling in an sCO2 Brayton cycle for concentrated solar power plants.” IAHR Int. Conf. on Cooling Tower and Heat, Univ. of Queensland, St. Lucia, QLD, Australia.
Singh, R., Miller, S. A., Rowlands, A. S., and Jacobs, P. A. (2013). “Dynamic characteristics of a direct-heated supercritical carbon dioxide Brayton cycle in a solar thermal power plant.” Energy, 50, 194–204.
Turchi, C. S., Ma, Z., and Dyreby, J. (2012). “Supercritical carbon dioxide power cycle configurations for use in concentrating solar power systems.”, ASME, New York.
Turchi, C. S., Ma, Z., Neises, T. W., and Wagner, M. J. (2013). “Thermodynamic study of advanced supercritical carbon dioxide power cycles for concentrating solar power systems” J. Sol. Energy Eng., 135(4), 041007.
Wang, M., Zhao, P., Wang, J., Li, H., and Dai, Y. (2016a). “Conceptual design and parametric study of combined carbon dioxide/organic Rankine cycles.” Appl. Therm. Eng., 103, 759–772.
Wang, X., and Dai, Y. (2016). “Exergoeconomic analysis of utilizing the transcritical CO2 cycle and the ORC for a recompression supercritical CO2 cycle waste heat recovery: A comparative study.” Appl. Energy, 170, 193–207.
Wang, X., Wang, J., Zhao, P., and Dai, Y. (2015). “Thermodynamic comparison and optimization of supercritical CO2 Brayton cycles with a bottoming transcritical CO2 cycle.” J. Energy Eng., 04015028.
Wang, X., Yang, Y., Zheng, Y., and Dai, Y. (2017). “Exergy and exergoeconomic analyses of a supercritical CO2 cycle for a cogeneration application.” Energy, 119, 971–982.
Wang, Y., Zhu, Y., Chen, H., Yang, L., and Yang, M. (2016b). “Thermal performance of a single pass all-glass parabolic trough receiver.” J. Energy Eng., 04016029.
Yari, M., and Sirousazar, M. (2010). “A novel recompression sCO2 Brayton cycle with pre-cooler exergy utilization.” Proc. Inst. Mech. Eng. Part A J. Power Eng., 224(7), 931–946.
Yoon, S. H., Kim, J. H., Hwang, Y. W., Kim, M. S., Min, K., and Kim, Y. (2003). “Heat transfer and pressure drop characteristics during the in-tube cooling process of carbon dioxide in the supercritical region.” Int. J. Refrig., 26(8), 857–864.
Zilio, C., Cecchinato, L., Corradi, M., and Schiochet, G. (2007). “An assessment of heat transfer through fins in a fin-and-tube gas cooler for transcritical carbon dioxide cycles.” HVAC&R Res., 13(3), 457–469.
Information & Authors
Information
Published In
Copyright
©2018 American Society of Civil Engineers.
History
Received: Jun 19, 2017
Accepted: Sep 18, 2017
Published online: Jan 26, 2018
Published in print: Apr 1, 2018
Discussion open until: Jun 26, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.