General Method for Predicting Capture Zone Widths for PV-Powered Pump-and-Treat Systems Using PVWATTS and Basic Hydrogeologic Data
Publication: Journal of Environmental Engineering
Volume 141, Issue 12
Abstract
Pump and treat (P&T) is one of the most commonly used technologies to remove and/or contain contaminated groundwater. An appropriate delineation of capture zones is necessary to design an effective P&T system. The study presented in this paper focuses on developing a feasibility level methodology to estimate capture zone widths for photovoltaic (PV)-powered P&T systems without energy storage throughout the continental United States as a function of daily average solar insolation data, transmissivity, and hydraulic gradient. Maps depicting predicted capture zone widths for specified transmissivity values and a hydraulic gradient are developed. The applicability of the developed methodology is illustrated with two actual sites where groundwater remediation has taken place. The methodology presented in this study can be used to assess the feasibility of PV-powered P&T systems without energy storage, in terms of capture zone width, anywhere within the continental United States. Detailed capture zone analysis should be performed during system design.
Get full access to this article
View all available purchase options and get full access to this article.
References
ArcMap version 10.0 [Computer software]. Redlands, CA, Esri.
Collins, E., Elmore, A. C., and Crow, M. (2013). “Using conditional probability to predict solar-powered pump-and-treat performance.” J. Hazard. Toxic Radioact. Waste, 31–37.
Conroy, J. P., Elmore, A. C., and Crow, M. (2013). “Capture zone comparison for photovoltaic microgrid-powered pump and treat remediation.” J. Hazard. Toxic Radioact. Waste, 04014009.
Cortes Di Lena, Y., and Elmore, A. C. (2013). “Performance evaluation of PV-powered pump and treat systems using typical meteorological year 3 data.” J. Hazard. Toxic Radioact. Waste,.04014004.
Cortes Di Lena, Y., Elmore, A. C., and Conroy, J. (2013). “Effectiveness of capture zones generated by intermittent pumping of a PV-powered pump-and-treat system without energy storage.” Remediation, 23(3), 111–122.
Davis, M. W., Dougherty, B. P., and Fanney, A. H. (2001). “Prediction of building integrated photovoltaic cell temperatures.” J. Solar Energy Eng., 123(3), 200–210.
Elmore, A. C., and DeAngelis, L. (2004). “Modeling a ground water circulation well alternative.” Ground Water Monit. Rem., 24(1), 66–73.
Elmore, A. C., and Gallagher, R. (2009). “Using regional climate center data to predict small wind turbine performance.” J. Hazard. Toxic Radioact. Waste, 14–19.
Elmore, A. C., and Vandeberg, M. A. (1997). “Using uncertainty analysis to reduce costs at a pump-and-treat site.” Remediation, 7(3), 5–21.
Esri. (2013). “GIS dictionary.” 〈http://support.esri.com/en/knowledgebase/Gisdictionary/browse〉 (Dec. 5, 2013).
Freeze, A., and Cherry, J. A. (1979). Groundwater, Prentice Hall, Englewood Cliffs, NJ.
Javandel, I., and Tsang, C. (1986). “Capture-zone type curves: A tool to aquifer cleanup.” Ground Water, 24(5), 616–625.
Marion, W., and Urban, K. (1995). User’s manual for TMY2s, National Renewable Energy Laboratory, Golden, CO.
Miller, J. A., and Appel, C. L. (1997). “High plains aquifer.” 〈pubs.usgs.gov/ha/ha730/ch_d/D-text2.html〉 (Dec. 6, 2013).
MiniTab 16 [Computer software]. State College, PA, Minitab.
Nativ, R., and Smith, D. A. (1987). “Hydrogeology and geochemistry of the Ogallala aquifer, southern high plains.” J. Hydrol., 91(3–4), 217–253.
NREL (National Renewable Energy Laboratory). (2013a). “Calculators.” PVWATTS, 〈〉 (Sep. 6, 2013).
NREL (National Renewable Energy Laboratory). (2013b). “U.S. solar radiation resource maps: Atlas of the solar radiation data manual for flat-plate and concentrating collectors.” 〈http://rredc.nrel.gov/solar/old_data/nsrdb/1961-1990/redbook/atlas/〉 (Aug. 26, 2013).
NREL (National Renewable Energy Laboratory). (2014). “USAF # 725500– Omaha Eppley airfield, NE (Class I).” 〈rredc.nrel.gov/solar/old_data/nsrdb/1991-2010/hourly/siteonthefly.cgi?id=725500〉 (Dec. 5, 2014).
U.S. EPA. (2008a). “Green remediation: Incorporating sustainable environmental practices into remediation of contaminated sites.” Office of Solid Waste and Emergency Response, Washington, DC.
U.S. EPA. (2008b). “Systematic approach for evaluation of capture zones at pump and treat systems.”, Office of Research and Development, Cincinnati, OH.
USGS (U.S. Geological Survey). (2013). “Study area setting.” 〈http://co.water.usgs.gov/nawqa/hpgw/html/SETT.html〉 (Dec. 6, 2013).
Visual MODFLOW Classic 2011.1 [Computer software]. ON, Canada, Schlumberger Water Services (SWS).
Wilcox, S., and Marion, W. (2008). Users manual for TMY3 data sets, National Renewable Energy Laboratory, Golden, CO.
Information & Authors
Information
Published In
Copyright
© 2015 American Society of Civil Engineers.
History
Received: Jan 14, 2014
Accepted: May 29, 2015
Published online: Jul 6, 2015
Published in print: Dec 1, 2015
Discussion open until: Dec 6, 2015