Abstract
Recent large earthquakes in China (e.g., Wenchuan earthquake and Yushu earthquake) resulted in enormous damage to school buildings and took many students’ lives. Recognizing the seismic vulnerability of existing school buildings, the Chinese government started a nationwide mission in 2009, aiming at increasing the seismic capacity of school buildings through inspection and retrofit activities. This paper presents the experiences of the authors in the retrofits of school buildings in which seismic isolation by using rubber and/or sliding bearings was adopted as a new and efficient retrofit technique, as compared with conventional ones. The retrofitted school buildings include masonry buildings, RC frame buildings, and a mixture of both. Design methods and the corresponding requirements in the modified seismic design code are presented, and typical construction procedures of the seismic retrofit are summarized from an engineer’s point of view. Procedures regarding the contract and review of the retrofit projects are also introduced. To this end, a case study is made to demonstrate the proposed design and construction methods. The presented work provides references to the seismic retrofit of existing buildings.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The support from (1) the Program for New Century Excellent Talents in University under Grant No. NCET-10-0326; (2) the Natural Science Foundation of Jiangsu (No. BC201120703); and (3) a project funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions is gratefully acknowledged.
References
Abrahamson, N. A. (1992). “Non-stationary spectral matching.” Seismol. Res. Lett., 63(1), 30.
Bailey, J. S., and Allen, E. W. (1988). “Seismic isolation retrofitting: Salt Lake City and County Building.” APT Bull., 20(2), 32–44.
Computers and Structures (CSI). (2007). CSI analysis reference manual for SAP2000, ETABS, and SAFE, Berkeley, CA.
Deluca, A., Mele, E., Molina, J., Verzeletti, G., and Pinto, A. V. (2001). “Base isolation for retrofitting historic buildings: Evaluation of seismic performance through experimental investigation.” Earthquake Eng. Struct. Dyn., 30(8), 1125–1145.
Guo, T., Wu, E., Li, A., Wei, L., and Li, X. (2011). “Integral lifting and seismic isolation retrofit of great hall of Nanjing Museum: Case study.” J. Perform. Constr. Facil., 558–566.
Hancock, J., et al. (2006). “An improved method of matching response spectra of recorded earthquake ground motion using wavelets.” J. Earthquake Eng., 10(1), 67–89.
Kawamura, S., Sugisaki, R., Ogura, K., Maezawa, S., Tanaka, S., and Yajima, A. (2000). “Seismic isolation retrofit in Japan.” Proc., 12 WCEE 2000, New Zealand Society for Earthquake Engineering, Silverstream, Upper Hutt, New Zealand, Paper No. 2523.
Masuzawa, Y., and Hisada, Y. (2004). “Seismic isolation retrofit of a prefectural government office building.” Proc., 13th World Conference on Earthquake Engineering, Canadian Association for Earthquake Engineering, Ottawa, Paper No. 1199.
Ministry of Housing and Urban-Rural Development of the People's Republic of China. (2010). “Code for seismic design of buildings.” Chinese design code GB 50011-2010, Beijing (in Chinese).
Miyamoto, H. K., Gilani, A. S. J., Erdurmus, S. B., and Akdogan, M. E. (2009). “Development of guidelines and effective retrofit strategies for public schools and hospitals in Istanbul, Turkey.” ATC and SEI 2009, Conf. on Improving the Seismic Performance of Existing Buildings and Other Structures, ASCE, Reston, VA, 268–280.
Mokha, A. S., Amin, N., Constantinou, M. C., and Zayas, V. (1996). “Seismic isolation retrofit of large historic building.” J. Struct. Eng., 298–308.
Zayas, V., and Low, S. (1990). “A simple pendulum technique for achieving seismic isolation.” Earthquake Spectra, 6(2), 317–333.
Zhao, B., Taucer, F., and Rossetto, T. (2009). “Field investigation on the performance of building structures during the 12 May 2008 Wenchuan earthquake in China.” Eng. Struct., 31(8), 1707–1723.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Jul 1, 2012
Accepted: Sep 26, 2012
Published online: Sep 28, 2012
Published in print: Feb 1, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.