Behavior of FRP-RC Slabs under Multiple Independent Air Blasts
Publication: Journal of Performance of Constructed Facilities
Volume 25, Issue 5
Abstract
In some terrorist attacks, it is possible that RC structures might be subjected to more than a single explosion. RC structures designed without the consideration of blast effects tend to lose their capacity after the first explosion. The use of a fiber reinforced polymer (FRP) sheet has been proven to enhance the performance and resistance of an RC member under a single explosion test. However, there appears to have been no experimental programs conducted to assess the performance of FRP-strengthened RC members subjected to multiple explosions reported in the literature. This paper, therefore, presents experimental results for the behavior of RC slabs strengthened by an FRP sheet after undergoing single, double, and triple independent explosion testing. Results from these blast tests indicate that the FRP sandwich RC slab tested was able to sustain the subsequent second explosion of greater impact. A brittle shear failure with FRP debonding was observed following the third explosion on this FRP-strengthened RC slab.
Get full access to this article
View all available purchase options and get full access to this article.
References
Crawford, J. E., Malvar, J, Morrill, K. B., and Ferritto, J. M. (2001). “Composite retrofits to increase the blast resistance of reinforced concrete buildings.” Proc., 10th Int. Symp. on Interaction of the Effects of Munitions with Structures, San Diego, 1–13.
MacGregor, J. G. (1997). “Reinforced concrete: Mechanics and design.” Shear in beams, Prentice Hall, Upper Saddle River, NJ, 180–231.
Ohkubo, K., Beppu, M., Ohno, T., and Satoh, K. (2008). “Experimental study on the effectiveness of fiber sheet reinforcement on the explosive-resistant performance of concrete plates.” Int. J. Impact Eng., 35(12), 1702–1708.
Silva, P. F., and Lu, B. (2007). “Improving the blast resistance capacity of RC slabs with innovative composites materials.” Composites, Part B, 38(5–6), 523–534.
Wu, C., et al. (2007). “Blast testing of RC slabs retrofitted with NSM CFRP plates.” Adv. Struct. Eng., 10(4), 397–414.
Wu, C., Oehlers, D. J., Rebentrost, M., Leach, J., and Whittaker, A. S. (2009). “Blast testing of ultra-high performance fibre and FRP-retrofitted concrete slabs.” Eng. Struct., 31(9), 2060–2069.
Information & Authors
Information
Published In
Copyright
© 2011 American Society of Civil Engineers.
History
Received: Apr 29, 2010
Accepted: Oct 30, 2010
Published online: Dec 3, 2010
Published in print: Oct 1, 2011
Authors
Metrics & Citations
Metrics
Citations
Download citation