Mechanics of Bond Fatigue Behavior of Concrete Beams Strengthened with NSM CFRP Rods
Publication: Journal of Composites for Construction
Volume 15, Issue 6
Abstract
Bond tests were conducted on 28 concrete beams strengthened with near-surface mounted (NSM) carbon-fiber-reinforced polymer (CFRP) rods under different fatigue load levels. In the NSM technique, the CFRP rods are placed inside precut grooves and bonded to the concrete with epoxy adhesive. The test variables included: presence of internal tension steel reinforcement (unreinforced or reinforced), type of CFRP rod (spirally wound or sandblasted), and the fatigue load level. The beams were tested in four-point bending. Bond failure was by debonding between the CFRP rod and the epoxy that started at sections close to the beam midspan. As the load was cycled further, debonding propagated toward the supports. At failure, the beams strengthened with a given rod type (sandblasted or spirally wound) showed the same CFRP strain at sections close to the support. The sandblasted rods showed a better bond fatigue performance than the spirally wound rods, which, at a given load level, failed at a higher number of cycles.
Get full access to this article
View all available purchase options and get full access to this article.
References
Aidoo, J., Harries, K. A., and Petrou, M. F. (2004). “Behavior of reinforced concrete bridge retrofit with CFRP and subjected to monotonic and fatigue loading.” Proc., 4th Int. Conf. on Advanced Composite Materials in Bridges and Structures (ACMBS 2004), Canadian Society for Civil Engineering, Montreal, QC, Canada.
American Concrete Institute (ACI) Committee 215. (1997). “Considerations for design of concrete structures subjected to fatigue loading.” 215R-92, Farmington Hills, MI.
American Concrete Institute (ACI) Committee 440. (2008). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” 440.2R-08, Farmington Hills, MI.
Canadian Standards Association (CSA). (2006). “Canadian highway bridge design code.” CAN/CSA S6-06, Mississauga, ON, Canada.
De Lorenzis, L., Rizzo, A., and La Tegola, A. (2002). “A modified pull-out test for bond of near-surface mounted FRP rods in concrete.” Composites, Part B, 33(8), 589–603.
De Lorenzis, L., Lundgren, K., and Rizzo, A. (2004). “Anchorage length of near-surface mounted fiber-reinforced polymer bars for concrete strengthening—Experimental investigation and numerical modeling.” ACI Struct. J., 101(2), 269–278.
De Lorenzis, L., and Nanni, A. (2002). “Bond between near-surface mounted bar-reinforced polymer rods and concrete in structural strengthening.” ACI Struct. J., 99(2), 123–132.
Hassan, T., and Rizkalla, S. (2003). “Investigation of bond in concrete structures strengthened with near-surface mounted carbon-fiber-reinforced polymer strips.” J. Compos. Constr., 7(3), 248–257.
Hassan, T., and Rizkalla, S. (2004). “Bond mechanism of near-surface-mounted fiber-reinforced polymer bars for flexural strengthening of concrete structures.” ACI Struct. J., 101(6), 830–839.
Novidis, D., and Pantazopoulou, S. (2008). “Bond tests of short NSM-FRP and steel bar anchorages.” J. Compos. Constr., 12(3), 323–333.
Quattlebaum, J. B., Harries, K. A., and Petrou, M. F. (2005). “Comparison of three CFRP flexural retrofit systems under monotonic and fatigue loadings.” J. Bridge Eng., 10(6), 731–740.
Rosenboom, O., and Rizkalla, S. (2006). “Behavior of prestressed concrete structures strengthened with various CFRP systems subjected to fatigue loading.” J. .Compos. Constr., 10(6), 492–502.
Taljsten, B., Carolin, A., and Nordin, H. (2003). “Concrete structures strengthened with near-surface-mount reinforcement of CFRP.” Adv. Struct. Eng., 6(3), 201–213.
Fédération Internationale du Béton (fib) [International Federation for Structural Concrete]. (2000). Bond of reinforcement in concrete: State-of-the-art report, Lausanne, Switzerland.
Wahab, N., Soudki, K. A., and Topper, T. (2008). “Bond of carbon-fiber-reinforced polymer rods to concrete in near-surface-mounted application under fatigue loading.” Proc., 2nd Canadian Conf. on Effective Design of Structures, Centre for Effective Design of Structures, McMaster Univ., Hamilton, ON, Canada, 195–205.
Wahab, N., Soudki, K. A., and Topper, T. (2011). “Mechanism of bond behavior of concrete beams strengthened with near-surface-mounted CFRP rods.” J. Compos. Constr., 15(1), 85–92.
Information & Authors
Information
Published In
Copyright
© 2011 American Society of Civil Engineers.
History
Received: Dec 8, 2010
Accepted: May 19, 2011
Published online: May 21, 2011
Published in print: Dec 1, 2011
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.