Seismic Performance of Direct Hung Suspended Ceiling Systems
Publication: Journal of Architectural Engineering
Volume 6, Issue 1
Abstract
Current seismic design philosophies require an earthquake-resistant building capable of resisting strong motion for structures and nonstructural elements. In response to the need to understand the seismic behavior of nonstructural elements, this paper presents the study on the vibration behavior and seismic capacity of direct hung suspended (DHS) ceiling systems. Modal analysis to investigate the eigen properties of the DHS ceilings was performed. Natural frequencies and mode shapes were identified using analytical models and verified by modal experiments. Different ceiling configurations were tested to understand their ultimate strength under incremental shock spectrum excitation. It was discovered that the 45° sway wires method prescribed by Ceiling and Interior System Contractors, does not increase the seismic capacity of the entire system. Based on recent field observations of DHS ceiling earthquake damage in Taiwan, it was found that pop rivets at the molding would increase the seismic capacity of the DHS systems. It was also discovered that a constraint transverse to the excitation direction would greatly influence the behavior of a DHS system.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
ANCO. (1983). “Seismic hazard assessment of nonstructural ceiling components.” NSF Rep. No. CEE-8114155.
2.
ANSYS User's Manual. (1993). Revision 5.0—Vol. III, Swanson Analysis Systems, Houston.
3.
Benuska, L. (1990). “Loma Prieta earthquake reconnaissance report.” Earthquake Spectra, Supplement to Vol. 6, 339–377.
4.
Ceiling and Interior System Contractors (CISCA). ( 1972). “Seismic restraint of direct hung suspended ceiling assemblies.” Chicago.
5.
Federal Emergency Management Agency (FEMA). (1997). “NEHRP recommended guidelines for the seismic rehabilitation of buildings.” FEMA 273, Washington, D.C.
6.
Phan, L. T., and Taylor, A. W. (1996). “State of the art report on seismic design requirements for nonstructural building components.” NISTIR 5857.
7.
Rihal, S. S., and Granneman, G. (1984). “Experimental investigation of the dynamic behavior of building partitions and suspended ceilings during earthquakes.” Rep. No. ARCE R84-1, California Polytechnic State University, Pomona, Calif.
8.
Sharpe, R., Kost, G., and Lord, J. ( 1973). “Behavior of structural systems under dynamic loads.” Building practices for disaster mitigation, Building Science Series 46, National Bureau of Standards, 352–394.
9.
Yao, G. C., Sheu, M. S., Sheu, D. S., and Mo, Y. L. (1996). “Performance of the shaking table in NCKU.” Proc., 3rd Nat. Conf. on Struct. Engrg., Pingdong, Taiwan, 2123–2132.
10.
Yao, G. C. (1995). “Seismic behavior study of architecture elements and equipment in hospitals.” NSC Rep. No. 84-2621-P-006-005B.
11.
Yao, G. C., and Lien, N. C. (1998). “Damage of nonstructural elements in Chia-I Ray-Li earthquake.” J Struct. Engrg., 13(3), 89–104.
Information & Authors
Information
Published In
History
Received: Mar 22, 1999
Published online: Mar 1, 2000
Published in print: Mar 2000
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.