Cathodic Protection of Reinforcing Steel in Concrete Using Conductive-Polymer System
Publication: Journal of Materials in Civil Engineering
Volume 16, Issue 4
Abstract
This paper presents experimental results from a novel study to investigate the feasibility of using a dual sacrificial anode cathodic protection (SACP) system that combined corrosion protection with strengthening. A conductive polymer was used to bond the zinc plates to the concrete surface to form the SACP system, while a single unidirectional carbon fiber-reinforced polymer (CFRP) sheet was bonded to the zinc surface to provide strengthening. However, the aim was not to evaluate strengthening, but to determine if the CFRP interfered with the performance of the SACP system. Four concrete prisms, two of which were strengthened, were tested. The specimens were all placed in a high humidity environment, and their potential and galvanic current measurements were carried out over the entire 295-day exposure period. It was found that the SACP system performed adequately, although there was an apparent decrease in the protective current due to passivation of the zinc plate. Although the potential results from both SACP systems studied (bare Zn plate versus Zn+CFRP ply) were different, the current delivery was similar, indicating little interference between the Zn plate and the carbon fiber ply attached on top of this plate.
Get full access to this article
View all available purchase options and get full access to this article.
References
Brousseau, R., Arnott, M., and Baldock, B. (1996). “Metallized and conductive coatings as impressed-current anodes for reinforced concrete: Part I.” Corrosion Prevention & Control, October, 119–130.
Clemeña, G. G., and Jackson, D. R. (1991). “Cathodic protection of the concrete piers of two bridges in Virginia using a water-based conductive coating.” Transportation Research Record 1304, Transportation Research Board, Washington, D.C., 160–166.
Clemeña, G. G., and Jackson, D. R. (1998). “Long term performance of conductive-paint anodes in cathodic protection systems for inland concrete piers in Virginia.” Transportation Research Record 1642, Transportation Research Board, Washington, D.C., 43–50.
Fontana, M. G. (1988). Corrosion engineering, 3rd Ed., McGraw-Hill, New York.
López, W., and González, J. A.(1993). “Influence of the degree of pore saturation on the resistivity of concrete and the corrosion ratio of steel reinforcement.” Cem. Concr. Res., 23, 368–376.
Master Builders Technology. (1998). “MBrace composite system for reinforcement.” Manufacturer’s Technical Brochure.
National Association of Corrosion Engineers (NACE). (2000). “Standardrecommended practice for impressed current cathodic protection of reinforcing steel in atmospherically exposed concrete structures.” NACE RP 0290-2000, Houston.
Powers, R. G., Sagüés, A. A., and Murase, T. (1992). “Sprayed-zinc galvanic anodes for the cathodic protection of reinforcing steel in concrete.” Proc., Materials: Performance and Prevention of Deficiencies and Failures, T. D. White, ed., ASCE, New York, 732–747.
Sagüés, A. A., Kranc, S. C., Al-Mansur, A. K. M., and Hierholzer, S. (1994a). “Factors controlling corrosion of steel-reinforced concrete substructure in seawater.” Final Rep. FL/DOT/RC/0537-3523, National Technical Information Service, Springfield, Va.
Sagüés, A. A., and Powers, R. G. (1994). “Sprayed zinc galvanic anodes for concrete marine bridge substructures.” Strategic Highway Research Program Rep. SHRP-S-405, National Research Council, Washington, D.C.
Sagüés, A. A., Powers, R., Murase, T., and Lasa, I. (1994b). “Low cost sprayed zinc galvanic anode for control of corrosion of reinforcing steel in marine bridge substructures.” Strategic Highway Research Program Final Rep. SHRP-88-ID024, National Research Council, Washington, D.C.
Stratfull, R. F. (1988). Criteria for the cathodic protection of bridge decks in corrosion for reinforcement in concrete construction, Ellis Horwood, Chichester, U.K.
Tudor, C., and Risk, R. (1998). “Metallizing: Current state of art.” Proc., Shipbuilding Conf.
3M. (2000). “P/N 3M zinc foil board.” Manufacturer’s Technical Brochure, St. Paul, Minn.
Information & Authors
Information
Published In
Copyright
Copyright © 2004 American Society of Civil Engineers.
History
Received: Jan 30, 2002
Accepted: Sep 23, 2003
Published online: Jul 15, 2004
Published in print: Aug 2004
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.