Calibrating Pipe Wall Demand Coefficient for Chlorine Decay in Water Distribution System
Publication: Journal of Water Resources Planning and Management
Volume 133, Issue 4
Abstract
Methodology and algorithm to calibrate pipe wall demand coefficients for chlorine decay using an input-output model framework are developed and applied. An input-output model of water quality in water distribution systems developed previously provides information that is not available using traditional simulation approaches: the various flow paths between particular input sources and output nodes, and their associated time delays and impacts on output node water quality. Such information constitutes a complete description of the input-output behavior under typical assumptions of first-order chemical decay or production reactions. With the input-output model, the chlorine concentration at output locations can be expressed explicitly as a function of the concentrations at upstream input locations, and pipe wall demand coefficients. Thus the sensitivity of water quality at the outputs to wall demand coefficients can be derived analytically and calculated efficiently. The sensitivity information is also used to study uncertainty in wall demand coefficient estimates that are caused by chlorine measurement errors.
Get full access to this article
View all available purchase options and get full access to this article.
References
Bard, Y. (1974). Nonlinear parameter estimation, Academic, New York.
Biswas, P., Lu, C., and Clark, R. M. (1993). “A model for chlorine concentration decay in pipes.” Water Res., 27(12), 1715–1724.
Boccelli, D., Tryby, M., Uber, J., Rossman, L., Zierolf, M., and Polycarpou, M. (1998). “Optimal scheduling of booster disinfection in water distribution systems.” J. Water Resour. Plann. Manage., 124(2), 99–111.
Clark, R. M., Grayman, W. M., Goodrich, J. A., Deininger, R. A., and Skov, K. (1994). “Measuring and modeling chlorine propagation in water distribution systems.” J. Water Resour. Plann. Manage., 120(6), 871–887.
Karim, M. R., Abbaszadegan, M., and LeChevallier, M. W. (2003). “Potential for pathogen intrusion during pressure transients.” J. Am. Water Works Assoc., 95(5), 134–146.
Kindermann, R., and Snell, J. L. (1980). Markov random fields and their application, American Mathematican Society.
LeChevallier, M. W. (1999). “The case for maintaining a disinfectant residual.” J. Am. Water Works Assoc., 91(1), 86–94.
Maier, S. H., Powell, R. S., and Woodward, C. A. (2000). “Calibration and comparison of chlorine decay models for a test water distribution system.” Water Resour. Res., 34(8), 2301–2309.
Powell, J. C., Hallam, N. B., West, J. R., Forster, C. F., and Simms, J. (2000). “Factors which control bulk chlorine decay rates.” Water Resour. Res., 34(1), 117–126.
Rossman, L., and Boulos, P. (1996). “Numerical methods for modeling water quality in distribution systems: A comparison.” J. Water Resour. Plann. Manage., 122(2), 137–146.
Rossman, L., Clark, R., and Grayman, W. (1994). “Modeling chlorine residuals in drinking-water distribution systems.” J. Environ. Eng., 120(4), 803–820.
Sekhar, M. (2001). “Disinfection by-product formation in the water distribution system of Morehead, Kentucky.” MS thesis, Univ. of Cincinnati, Cincinnati.
Shang, F., Uber, J., and Polycarpou, M. (2002). “Particle backtracking algorithm for water distribution system analysis.” J. Environ. Eng., 128(5), 441–450.
Vasconcelos, J. J., Rossman, L. A., Grayman, W. M., Boulos, P. F., and Clark, R. M. (1997). “Kinetics of chlorine decay.” J. Am. Water Works Assoc., 89(7), 54–65.
Zierolf, M., Polycarpou, M., and Uber, J. (1998). “Development and auto-calibration of an input-output model of chlorine transport in drinking water distribution systems.” IEEE Trans. Control Syst. Technol., 6(4), 543–553.
Information & Authors
Information
Published In
Copyright
© 2007 ASCE.
History
Received: Jan 18, 2006
Accepted: Mar 13, 2006
Published online: Jul 1, 2007
Published in print: Jul 2007
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.