Three-Dimensional Effects on Openings of Laterally Loaded Pierced Shear Walls
Publication: Journal of Structural Engineering
Volume 130, Issue 10
Abstract
Current design provisions comprise broadly described information for the detailing of reinforcement around the openings of pierced shear walls. To address this deficiency, the load capacity and stress distribution around the openings were analyzed by conducting three-dimensional (3D) nonlinear pushover analyses on typical shear wall dominant building structures. The diaphragm flexibility, behavior of transverse walls and slab-wall interaction during the 3D action were investigated in addition to effects of 3D and 2D modeling on the capacity evaluation. An effort was spent to illuminate the significance of different size and location of openings within the pierced walls having variable reinforcement ratios. The results of this study indicated that the stress flow and crack patterns around the openings of the 3D cases were drastically different than those computed for the 2D cases. The tension–compression coupling effects caused by the wall-to-wall and wall-to-slab interactions provided a significant contribution for increasing the global lateral resistance.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Ali, A., and Wight, J. K. (1991). “RC structural walls with staggered door openings.” J. Struct. Eng., 117(5), 1514–1531.
2.
American Concrete Institute (ACI). ( 1990). “Commentary on code requirements for nuclear safety related concrete structures.” ACI Manual Part 4, Nuclear Safety Structures Code, 349-90, Chap. 14.3.4, Detroit, 349–360.
3.
American Concrete Institute (ACI). ( 1995). “Building code requirements for reinforced concrete and commentary.” Committee 318, Detroit, 73–74, 218, 242.
4.
Arvidsson, K. (1974). “Shear walls with door openings near the edge of the wall.” J. ACI Proc., 71(7), 353–357.
5.
Balkaya, C., and Kalkan, E. (2003a). “Nonlinear seismic response evaluation of tunnel form building structures.” Comput. Struct., 81, 153–165.
6.
Balkaya, C., and Kalkan, E. (2003b). “Estimation of fundamental periods of shear wall dominant building structures.” Earthquake Eng. Struct. Dyn., 32(7), 985–998.
7.
Balkaya, C., and Schnobrich, W. C. (1993). “Nonlinear 3D behavior of shear wall dominant RC building structures.” Struct. Eng. Mech., 1(1), 1–16.
8.
Benjamin, J. R., and Williams, H. A. (1958). “Behavior of one-story reinforced concrete shear walls containing openings.” J. ACI Proc., 55(5), 605–618.
9.
Daniel, J. I., Shiu, K. N., and Corley, W. G. (1986). “Openings in earthquake-resistant structural walls.” J. Struct. Eng., 112(7), 1660–1676.
10.
El-Mezaini, N., and Citipitioglu, E. (1991). “Finite element analysis of prestressed and reinforced concrete structures.” J. Struct. Eng., 117(10), 2851–2864.
11.
Gallegos-Cezares, S., and Schnobrich, W. C. ( 1988). “Effects of creep and shrinkage on the behavior of reinforced concrete gable roof hyperbolic-paraboloids.” Struct. Research Series 543, UIUC.
12.
Gupta, A. K., and Akbar, H. (1984). “Cracking in reinforced concrete analysis.” J. Struct. Eng., 110(8), 1735–1746.
22.
International Conference of Building Officials (ICBO). ( 1997). Uniform building code, Whittier, Calif.
13.
Kunnath, S.K. ( 2004). “Identification of modal combinations for nonlinear static analysis of building structures.” Comput. Aided Civ. Infrastruct. Eng., in press.
14.
Matsui, G., and Ogawa, T. (1979). “Study on methods of arranging openings in box frame type construction and shearing stress distribution.” Trans. Architectural Institute Japan, 286, 37–43.
15.
Milford, R. V., and Schnobrich, W. C. (1985). “The application of the rotating crack model to the analysis of reinforced concrete shells.” Comput. Struct., 20, 225–234.
16.
Ministry of Public Works and Settlement. ( 1998). “Specifications for structures to be built in disaster areas.” Ankara, Turkey.
17.
Ohtani, H. (1989). “Study of design method of crack width control in openings corner on walls with window openings of reinforced concrete.” J. Struct. Constr. Eng., 400, 33–34.
18.
Paulay, T., and Binney, J. R. ( 1974). “Diagonally reinforced coupling beams of shear walls.” Shear in reinforced concrete, ACI Publication SP-42, Detroit, 579–598.
19.
Paulay, T., and Priestley, M.J. N. ( 1992). Seismic design of reinforced concrete and masonry buildings,” Wiley, New York, 744–799.
21.
Seya, Y., and Matseri, G. (1979). “Study of stress and displacement of shear wall with opening.” Trans. Architectural Institute Japan, 286, 45–53.
23.
Vecchio, F. J., and Collins, M. P. (1986). “The modified compression-field theory for reinforced concrete elements subjected to shear.” ACI Struct. J., 83(2), 219–231.
24.
Yamada, M., Kawamura, H., and Katagihara, K. ( 1974). “Reinforced concrete shear walls with openings: Test and analysis.” Shear in Reinforced Concrete, Publication SP-42, ACI, Detroit, 559–578.
25.
Wood, S. L. (1990). “Shear strength of low-rise reinforced concrete walls.” ACI Struct. J., 87(1), 99–107.
Information & Authors
Information
Published In
Copyright
Copyright © 2004 ASCE.
History
Published online: Oct 1, 2004
Published in print: Oct 2004
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.