Behavior of Cross-Bracing in Latticed Towers
Publication: Journal of Structural Engineering
Volume 124, Issue 4
Abstract
Cross-bracing in which the bolted steel angle members are alternately in compression and tension is widely used in latticed tower structures. Within each set of cross-bracing, the tie is generally assumed to restrain the strut at the cross-over joint. A series of 13 tests on cross-bracing systems is described, with slenderness ratios in the range of 102 to 160. Other variables include the inclination of the main legs and bracing, the number of bolts in each end connection, and the size of the main leg relative to the bracing. The measured behavior is compared with the results of a flexibility-based analysis and the formulas from the American and European transmission tower design manuals. The behavior is complex, but the importance of end eccentricity and number of bolts in the connection of the bracing to the main legs is apparent in these results. A secant-based design formulation is shown to provide accurate predictions of the strength of the cross-bracing.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
ASCE. (1988). Guide for design of steel transmission towers, 2nd Ed. Reston, Va.
2.
Behncke, R. H. (1986). “Behavior of crossed diagonals in transmission line latticed towers,” MSc dissertation, Univ. of the Witwatersrand, Johannesburg, South Africa.
3.
Behncke, R. H. (1992). “An experimental and theoretical investigation of the structural behavior of cross-bracing in transmission line steel towers,” Phd thesis, Univ. of the Witwatersrand, Johannesburg, South Africa.
4.
CIGRE. (1974). “Buckling tests on crossed diagonals in latticed towers.”Test Rep. 22-74-WG08-1. Mannheim, Germany.
5.
Elmes, R. D. (1981). “The strength of cross-bracing members found in latticed towers,” MSc project report, Univ. of the Witwatersrand, Johannesburg, South Africa.
6.
European Commission for Constructional Steelwork (ECCS). (1985). “Recommendations for angles in latticed transmission towers.”Manual No. 39, Rotterdam, The Netherlands.
7.
Haaijer, G., Carskaddon, P. S., and Grubb, M. A. (1981). “Eccentric load tests of angle columns simulated with MSC/NASTRAN finite element program.”Proc., Annu. Mtg. of Steel Struct. Res. Committee, Chicago, Ill.
8.
Kemp, A. R.(1988). “A consistent mixed approach to computer analysis of frames.”The Civ. Engr. in South Africa, 30(7), 425–432.
9.
Le Master, R. A. (1988). “Structural development studies at the EPRI Transmission Line Mechanical Research Center.”Rep. EL-5488. EPRI.
10.
Lu, L. W., Shen, Z. K., and Hu, H. R. (1983). “Inelastic instability research at Lehigh University.”Proc., M.R. Horne Int. Conf. on Instability and Plastic Collapse of Steel Struct., Univ. of Manchester, U.K., 273–282.
11.
Short, J., and Morse, J. (1979). “The variation between predicted and actual performance of transmission towers under test conditions.”Proc., Inst. of Elec. Engrg., London, U.K.
12.
Trahair, N. S., Usami, T., and Galambos, T. V. (1969). “Eccentrically loaded single angle columns.”Res. Rep. No. 11, Dept. of Civ. Engrg., Washington Univ., St. Louis, Mo.
13.
Usami, T., and Galambos, T. V.(1971). “Eccentrically loaded single-angled columns.”Int. Assn. of Bridge and Strut. Engrg., 31(2), 153–184.
14.
Wood, A. B. (1975). “Buckling tests on crossed diagonals in latticed towers.”CIGRE Report, Electra, No. 38, 88–99.
Information & Authors
Information
Published In
Copyright
Copyright © 1998 American Society of Civil Engineers.
History
Published online: Apr 1, 1998
Published in print: Apr 1998
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.