Structural Implications of Increased Panel Use in Wood-Frame Buildings
Publication: Journal of Structural Engineering
Volume 121, Issue 6
Abstract
To improve performance and lower cost, conventional wood-frame construction has evolved to incorporate increasing numbers of manufactured components. Through recent work at the Massachusetts Institute of Technology (MIT) to develop a panelized roof system, other, more general observations have been made about the structural implications of panel use, and these observations form the basis for this paper. A partial exploration of structural response in conventional wood-frame construction is included as background, with a particular emphasis on sheathing. Panelized and modularized buildings represent a significant shift from historical practice, with structural implications for floors, walls, and roofs. Without the structural redundancy and load sharing that continuous envelope sheathing provides, panelized wood-frame buildings require more and careful engineering to achieve performance comparable to conventional construction. Floors, walls, and roofs need panel-to-panel joints that resist differential transverse deflection and possess in-plane shear strength and stiffness comparable to site-built, staggered-sheathed assemblies. Wherever structural response includes diaphragm action, the disruption of sheathing and perimeter-chord continuity both have consequences for panelized building systems.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Adams, N. R. (1987). “Plywood shear walls.”Rep. No. 105, Am. Plywood Assoc., Tacoma, Wash.
2.
Åkerlund, S.(1985). “Discussion of `Behavior of wood-framed shear walls,' by A. K. Gupta and G. P. Kuo.”J. Struct. Engrg., ASCE, 113(11), 2306–2309.
3.
Am. Plywood Assoc. (1991). “APA design/construction guide: Diaphragms.”Rep., Tacoma, Wash.
4.
Aune, P., and Patton-Mallory, M. (1986a). “Lateral load-bearing capacity of nailed joints based on the yield theory: Experimental verification.”Rep. No. FPL 470, U.S.D.A. Forest Service, Forest Products Lab., Madison, Wis.
5.
Aune, P., and Patton-Mallory, M. (1986b). “Lateral load-bearing capacity of nailed joints based on the yield theory: Theoretical verification.”Rep. No. FPL 470, U.S.D.A. Forest Service, Forest Products Lab., Madison, Wis.
6.
Canfield, L. R., Niu, S. H., and Liu, H.(1991). “Uplift resistance of various rafter-wall connections.”Forest Products J., 41(7/8), 27–34.
7.
Ching, F. D. K., and Adams, C. (1991). Building construction illustrated. Van Nostrand Reinhold, New York, N.Y.
8.
Conner, H. W., Gromala, D. S., and Burgess, D. W.(1987). “Roof connections in houses: Key to wind resistance.”J. Struct. Engrg., ASCE, 113(12), 2459–2474.
9.
Cramer, S. M., and Wolfe, R. W.(1989). “Load-distribution model for light-frame wood roof assemblies.”J. Struct. Engrg., ASCE, 115(10), 2603–2616.
10.
Crowley, J., et al. (1992). “Innovative materials and construction systems for energy efficient building envelopes.”Proc., 5th Thermal Perf. of the Exterior Envelope of Build. Conf., December, 1992, Am. Soc. of Heating, Refrigerating, and Air-Conditioning Engrs., Inc. (ASHRAE), Atlanta, Ga.
11.
Crowley, J., Dentz, J., Morse-Fortier, L., and Parent, M.(1993). “Reinventing wood frame construction: Development of an innovative roof component system.”Forest Products J., 43(7/8), 27–35.
12.
Dietz, A. G. H. (1974). Dwelling house construction. MIT Press, Cambridge, Mass.
13.
Dolan, J. D., and Foschi, R. O.(1991). “Structural analysis model for static loads on timber shear walls.”J. Struct. Engrg., ASCE, 117(3), 851–861.
14.
Filiatrault, A.(1990). “Static and dynamic analysis of timber shear walls.”Can. J. Civ. Engrg., 17(4), 643–651.
15.
Foschi, R. O.(1982). “Structural analysis of wood floor systems.”J. Struct. Div., ASCE, 108(7), 1557–1574.
16.
Foschi, R. O.(1985). “Wood floor behavior: Experimental study.”J. Struct. Engrg., ASCE, 111(11), 2497–2508.
17.
Foschi, R. O., and Bonac, T.(1977). “Load-slip characteristics for connections with common nails.”Wood Sci., 9(3), 118–123.
18.
Goel, R. K., and Chopra, A. K.(1991). “Effects of plan asymmetry in inelastic seismic response of one-story systems.”J. Struct. Engrg., ASCE, 117(5), 1492–1513.
19.
Goers, R. W. (1976). “A methodology for seismic design and construction of single-family dwellings.”Rep. Prepared for Appl. Technol. Council, Dept. of Housing and Urban Development, Div. of Energy, Build. Technol. and Standards, Ralph W. Goers and Associates, Struct. Engrs., Van Nuys, Calif.
20.
Gray, R. G. (1991). “Riding out the big one.”Fine homebuilding, 64(Dec./Jan.), 60–65.
21.
Gromala, D. S., and Polensek, A. (1981). “Analysis and design of wall systems under axial and bending loads.”Proc., Wall and Floor Systems, Des. and Perf. of Light-Frame Struct., Forest Products Res. Soc., Madison, Wis., 87–100.
22.
Gromala, D. S., and Wheat, D. L. (1984). “Structural analysis of light-frame subassemblies.”Proc., Struct. Wood Res. : State-of-the-art and Res. Needs, R. Y. Itani and K. F. Fahertys, eds., ASCE, New York, N.Y., 73–108.
23.
Gupta, A. K., and Kuo, G. P.(1985). “Behavior of wood-framed shear walls.”J. Struct. Engrg., ASCE, 111(8), 1722–1733.
24.
Gupta, A. K., and Kuo, G. P.(1987). “Wood-framed shear walls with uplifting.”J. Struct. Engrg., ASCE, 113(2), 241–259.
25.
Gutkowski, R. M., and Castillo, A. L.(1988). “Single- and double-sheathed wood shear wall study.”J. Struct. Engrg., ASCE, 114(6), 1268–1284.
26.
Herbert, G. (1986). The dream of the factory made house, Walter Gropius and Konrad Wachsmann. MIT Press, Cambridge, Mass.
27.
Johnson, J. W.(1972). “Lateral tests of wood roof sections sheathed with decking.”Forest Products J., 22(6), 54–55.
28.
Mack, J. J.(1977). “The load-displacement curve for nailed joints.”J. Inst. Wood Sci., 7(6), 34–36.
29.
McCarthy, M., and Wolfe, R. (1986). “Current topics in forest research: emphasis on contributions by women scientists.”Proc., Nat. Symp. ; General Tech. Rep. SE-46. U.S.D.A. Forest Service, Asheville, N.C.
30.
McCutcheon, W. J.(1985). “Racking deformations in wood shear walls.”J. Struct. Engrg., ASCE, 111(2), 257–269.
31.
Miller, C. (1992). “Hurricane warnings.”Fine homebuilding. The Taunton Press, 78(Dec./Jan.), 82–87.
32.
Moody, R. C., and Schmidt, R. J. (1988). “Lateral loading of wood frame houses—analysis and performance.”Proc., 1988 Int. Conf. on Timber Engrg., R. Y. Itani, ed., Vol. 1, 62–72.
33.
Nelson, E. L., Wheat, D. L., and Fowler, D. W.(1985). “Structural behavior of wood shear wall assemblies.”J. Struct. Engrg., ASCE, 111(3), 654–666.
34.
Patton-Mallory, M., Gutkowski, R. M., and Soltis, L. A. (1984). “Racking performance of light-frame walls sheathed on two sides.”Rep. No. FPL 448, U.S.D.A. Forest Service, Forest Products Lab., Madison, Wis.
35.
Patton-Mallory, M., Wolfe, R. W., Soltis, L. A., and Gutkowski, R. M.(1985). “Light-frame shear wall length and opening effects.”J. Struct. Engrg., ASCE, 111(10), 2227–2239.
36.
Peterson, J.(1983). “Bibliography on lumber and wood panel diaphragms.”J. Struct. Engrg., ASCE, 109(12), 2838–2852.
37.
Polensek, A.(1976a). “Finite element analysis of wood-stud walls.”J. Struct. Div., ASCE, 102(7), 1317–1335.
38.
Polensek, A. (1976b). “Nonlinear behavior of nailed wood-stud walls at service loads and overloads.”Proc., 2nd Int. Conf. on Mech. Behavior of Mat., Federation of Mat. Soc., Boston, Mass., 1948–1952.
39.
Polensek, A.(1977). “Rational design procedure for wood-stud walls under bending and compression loads.”Wood Sci., 9(1), 8–20.
40.
Polensek, A.(1978). “Properties of components and joints for rational design procedure of wood-stud walls.”Wood Sci., 10(4), 167–175.
41.
Polensek, A. (1983). “Structural analysis of light-frame wood buildings.”Proc., Struct. Wood Res. : State-of-the-art and Res. Needs, R. Y. Itani and K. F. Fahertys, eds., ASCE, New York, N.Y., 189–206.
42.
Polensek, A., and Schimel, B. D.(1986). “Rotational restraint of wood-stud wall supports.”J. Struct. Engrg., ASCE, 112(6), 1247–1262.
43.
Polensek, A., and Schimel, B. D.(1988). “Analysis of nonlinear connection systems in wood dwellings.”J. Computing in Civ. Engrg., ASCE, 2(4), 365–379.
44.
Polensek, A., and Schimel, B. D.(1991). “Dynamic properties of light-frame wood subsystems.”J. Struct. Engrg., ASCE, 117(4), 1079–1095.
45.
Reardon, G. F. (1987). “Roof structure for domestic buildings.”Proc., JCU Papers at 7th Int. Conf. on Wind Engrg., James Cook Univ. of North Queensland, Australia.
46.
Saffir, H. S. (1989). “Florida's approach to hurricane resistant design and construction.”J. Wind Engrg. and Industrial Aerodynamics, Vol. 32, 221–230.
47.
Schaefer, E. M., and Vanderbilt, M. D.(1983). “Comprehensive analysis methodology for wood floors.”J. Struct. Engrg., ASCE, 109(7), 1680–1694.
48.
Schmidt, R. J., and Moody, R. C.(1989). “Modeling laterally loaded light-frame buildings.”J. Struct. Engrg., ASCE, 115(1), 201–217.
49.
Schodek, D. (1992). Structures. Prentice-Hall, Inc., Englewood Cliffs, N.J.
50.
Sherwood, G., and Moody, R. C. (1989). “Light frame wall and floor systems: Analysis and performance.”Rep. No. FPL GTR 59, U.S.D.A. Forest Service, Forest Products Lab., Madison, Wis.
51.
Soltis, L. A., Gromala, D. S., and Tuomi, R. L. (1980). “Seismic performance of low-rise wood buildings.”Proc., NSF Workshop on Perf. of Low Rise Build., Illinois Inst. of Technol., Chicago, Ill., 78–98.
52.
Soltis, L. A., Wolfe, R. W., and Tuomi, R. L. (1981). “Design approaches for light-frame racking walls.”Proc., Wall and Floor Systems, Des. and Perf. of Light-Frame Struct., Forest Products Res. Soc., Madison, Wis., 101–110.
53.
Southern Building Codes Congress International (SBCCI). (1990). “Deemed-to-comply standard for single and multifamily dwellings in high wind regions.”Rep. No. SSTD 10-90, Birmingham, Ala.
54.
Stevenson, K. C., and Jandl, H. W. (1986). Houses by mail : A guide to houses from Sears, Roebuck and Company. The Preservation Press, Washington, D.C.
55.
Thorburn, H. J., and Schriever, W. R. (1960). “Loading tests on full-scale house roofs.”Rep. No. 312, ASTM, Philadelphia, Pa.
56.
Tissell, J. R. (1989). “Panel-sheathed shearwalls—Past, present and future.”Proc., Struct. Des., Anal., and Testing —Proc., Sessions Related to Des., Anal., and Testing at Struct. Cong. '89, A. H.-S. Angs, ed., ASCE, New York, N.Y., 124–133.
57.
Tissell, J. R. (1990a). Wind and Seismic Effects : Proc., 22nd Joint Panel Conf. of the U.S.-Japan Cooperative Program in Natural Resour., Nat. Bureau of Standards, Washington, D.C., Vol. 796.
58.
Tissell, J. R. (1990b). “Structural panel shear walls.”Rep. No. 154, Am. Plywood Assoc., Tacoma, Wash.
59.
Tissell, J. R., and Elliott, J. R. (1990). “Plywood diaphragms.”Rep. No. 138, Am. Plywood Assoc., Tacoma, Wash.
60.
Trent, T. R. (1989). “Factory-made housing.”Housing economics, XXXVII(10), 4–7.
61.
Tuomi, R. L., and Gromala, D. S. (1977). “Racking strength of walls: Let-in corner bracing, sheet materials and effect of loading rate.”Rep. No. FPL 301, U.S.D.A. Forest Service, Forest Products Lab., Madison, Wis.
62.
Uniform building code. (1988). International Conference of Building Officials, (ICBO), Whittier, Calif.
63.
Walker, G. R. (1987). “The design of walls in domestic housing to resist wind.”Proc., JCU Papers at 7th Int. Conf. on Wind Engrg., James Cook Univ. of North Queensland, Australia.
64.
Wheat, D. L., and Moody, R. C. (1984). “Predicting the strength of wood-joist floors.”Rep. No. FPL 445, U.S.D.A. Forest Service, Forest Products Lab., Madison, Wis.
65.
Wilkinson, T. L. (1971). “Theoretical lateral resistance of nailed joints.”J. Struct. Div., ASCE, 97(ST5), 1381–1398.
66.
Wolfe, R. W., and LaBissoniere, T. (1991). “Structural performance of light-frame roof assemblies, Part II: Conventional truss assemblies.”Rep. No. FPL 499, U.S.D.A. Forest Service, Forest Products Lab., Madison, Wis.
Information & Authors
Information
Published In
Copyright
Copyright © 1995 American Society of Civil Engineers.
History
Published online: Jun 1, 1995
Published in print: Jun 1995
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.