Ultimate Behavior of Heavy Steel Section Welded Splices and Design Implications
Publication: Journal of Structural Engineering
Volume 116, Issue 8
Abstract
Full‐ and partial‐penetration butt‐welded splices of American Institute of Steel Construction (AISC) group four and five rolled steel sections are tested. Test specimens are devised so splices are located in regions of pure bending. The partial‐penetration splice is able to develop and exceed its nominal capacity. However, it fails in a brittle manner with no apparent ductility. Qualitative explanations are given as to the cause of the observed failure. The adequacy of simple strength‐design methods to predict that behavior is assessed. Also, an example is presented for braced frames designed according to the Uniform Building Code (UBC). The acceptability of partial‐penetration welds in that design is reviewed by comparing the member forces obtained from the static analysis with those resulting from an inelastic step‐by‐step dynamic analysis. The specimen with a full‐penetration welded splice exhibits satisfactory strength and ductility. It is believed, however, that a great amount of care must be taken in the execution of this type of weld. Design implications of those results for seismic resistant structures are examined.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Bjorhovde, R. (1987). “Welded splices in heavy wide‐flange shapes.” Proc. Nat. Engrg. Conf. and Conf. of Operating Personnel, New Orleans.
2.
Blodgett, O. W. (1977). “Why welds crack—How cracks can be prevented.” Publication G230, The Lincoln Electric Co., Cleveland, Ohio.
3.
Blodgett, O. W. (1979). “Distortion … how to minimize it with sound design practices and controlled welding procedures plus proven methods for straightening distorted members.” Publication G261, The Lincoln Electric Co., Cleveland, Ohio.
4.
Bruneau, M., Mahin, S. A., Popov, E. P. (1987). “Ultimate behavior of butt welded splices in heavy rolled steel sections.” EERC Report No. 87‐10, Sep., Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
5.
“Commentary on highly restrained welded connections.” (1973). Engrg. J. Am. Inst. Steel Constr., 10(3).
6.
Doty, W. D. (1987). “Procedures for thermal cutting and welding heavy structural shapes.” Nat. Engrg. Conf. and Conf. of Operating Personnel, New Orleans, April 29–May 2, 1987, p. 16–1.
7.
Fisher, J. W., and Pense, A. W. (1987). “Experience with use of heavy W shapes in tension.” Engrg. J. Am. Inst. Steel Constr., 24(2), 63–77.
8.
“Fundamentals of welding.” (1976). Welding handbook: Vol. 1, 7th Ed., American Welding Society, Miami, Fla.
9.
Kaufmann, E. J., and Stout, R. D. (1983). “The toughness and fatigue strength of welded joints with buried Lamellar tears.” Welding Research—Supplement to the Welding J., American Welding Society, Nov., G2(11).
10.
Mahin, S. A., and Bertero, V. V. (1976). “Problems in establishing and predicting ductility in aseismic design.” Int. Symp. on Earthquake Structural Engineering, Aug., 613–628.
11.
Park, R., and Paulay, T. (1975). Reinforced concrete structures. John Wiley and Sons, Inc., New York, N.Y.
12.
Popov, E. P., and Stephen, R. M. (1976). “Tensile capacity of partial penetration welds.” EERC Report No. 70‐3, Oct., Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
13.
Preece, F. R. (1981). “Structural steel in the 80's—Materials, fastening and testing.” The Steel Committee of California, San Francisco, Calif.
14.
“Recommended Lateral Force Requirements and Tentative Commentary—1988.” (1988). Seismology Committee, Structural Engineers Association of California.
15.
“Specifications for the design, fabrication and erection of structural steel for buildings with commentary.” (1980). Manual of steel construction, AISC, Chicago, Ill.
16.
“Specifications for the design, fabrication and erection of structural steel buildings with commentary: Supplement no. 2.” (1989). Manual of Steel Construction, AISC, Chicago, Ill.
17.
Tuchman, J. L. (1986). “Cracks, fractures spur study.” Engrg. News Rec., Aug. 21.
18.
Uniform building code. (1985). International Conference of Building Officials, Pasadena, Calif.
19.
Uniform building code. (1988). International Conference of Building Officials, Pasadena, Calif.
20.
“Welding manual for heavy wide flange shapes.” (1983). Nippon Steel Corp., Sep.
21.
Yurioka, N., et al. (1983). “Determination of necessary preheating temperature in steel welding.” Welding Research—Supplement to the Welding J., American Welding Society, Jun.
Information & Authors
Information
Published In
Copyright
Copyright © 1990 ASCE.
History
Published online: Aug 1, 1990
Published in print: Aug 1990
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.