Optimal Control: Basis for Performance Comparison of Passive and Semiactive Isolation Systems
Publication: Journal of Engineering Mechanics
Volume 132, Issue 7
Abstract
Passive damping in shock and vibration isolation systems reduces the deformation of the isolation system but can increase the acceleration sustained by the isolated object. Semiactive (i.e., controllable) damping systems offer a solution to the problem of increased vibration transmissibility at high frequencies. Semiactive damping is especially relevant to protecting acceleration-sensitive components to the effects of large impulsive earthquakes. In this paper, we compare three semiactive control policies, i.e., pseudonegative-stiffness control, continuous pseudoskyhook-damping control, and bang-bang pseudoskyhook-damping control, in terms of their effectiveness in addressing the deficiencies of passive isolation damping. In order to establish a performance goal for these suboptimal semiactive control rules, we present a method for true optimization of the response of dynamically excited, semiactively controlled structures subjected to constraints imposed by the dynamics of a particular semiactive device. The optimization procedure involves solving Euler–Lagrange equations. The closed-loop dynamics of structures with semiactive control systems are nonlinear due to the parametric nature of the control actions. These nonlinearities preclude an analytical evaluation of Laplace transforms. In this paper, frequency response functions for semiactively controlled structural systems are compiled from the computed time history responses to sinusoidal and pulse-like base excitations. For control devices with no saturation forces, the closed-loop frequency response functions are independent of the excitation amplitude. We make use of this homogeneity of the solution of semiactive control systems and present results in dimensionless form.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers gratefully acknowledge support from the National Science Foundation for this work under Grant No. NSFCMS-9900193 and the Scientific and Technical Research Council of Turkey (NATO-B1 Research Scholarship) and Istanbul Technical University.
References
Alhan, C., and Gavin, H. (2004). “A parametric study of linear and nonlinear passively damped seismic isolation systems for buildings.” Eng. Struct., 26(4), 485–497.
Chen, G., and Wu, J. (2001). “Optimal placement of multiple tuned mass dampers for seismic structures.” J. Struct. Eng., 127(9), 1054–1062.
Gavin, H. P. (2001). “Control of seismically excited vibration using electrorheological materials and Lyapunov methods.” IEEE Trans. Control Syst. Technol., 9(1), 27–36.
Gavin, H., and Aldemir, U. (2001). “Behavior and response of auto-adaptive seismic isolation.” Proc., 3rd U.S.–Japan Workshop in Urban Earthquake Disaster Mitigation, Seattle, 120–128.
Heaton, T. H., Hall, J. F., Wald, D. J., and Halling, M. W. (1995). “Response of high-rise and base-isolated buildings to a hypothetical 7.0 blind thrust earthquake.” Science, 267, 206–211.
Housner, G. W., et al., (1997). “Structural control: Past, present, and future.” J. Eng. Mech., 123(9), 897–971.
Iemura, H., and Pradono, M. H. (2003). “Application of pseudonegative stiffness control to the benchmark cable-stayed bridge.” J. Struct. Control, 10, 187–204.
Karnopp, D. (1995). “Active and semiactive vibration isolation.” Trans. ASME, J. Vib. Acoust., 117, 177–185.
Kelly, J. M. (1999). “The role of damping in seismic isolation.” Earthquake Eng. Struct. Dyn., 25, 3–20.
Kirk, D. E. (2004). Optimal control theory: An introduction, Dover, New York.
Margolis, D. L. (1983). “A procedure for comparing passive, active, and semiactive approaches to vibration isolation.” J. Franklin Inst., 315(4), 225–238.
Nagarajaiah, S., and Xiahong, S. (2000). “Response of base-isolated USC hospital building in Northridge Earthquake.” J. Struct. Eng., 126(10), 1177–1186.
Ramallo, J. C., Johnson, E. A., and Spencer, B. F. (2002). “Smart base isolation systems.” J. Eng. Mech., 128(10), 1088–1099.
Spencer, B. F., and Nagarajaiah, S. (2003). “State of the art of structural control.” J. Struct. Eng., 129(7), 845–856.
Spencer, B. F., and Sain, M. K. (1997). “Controlling buildings: A new frontier in feedback.” IEEE Control Syst. Mag., 17(6), 19–35.
Stengel, R. F. (1994). Optimal control and estimation, Dover, New York.
Symans, M. D., and Constantinou, M. C. (1999). “Semiactive control systems for seismic protection of structures: A state-of-the-art review.” Eng. Struct., 6, 469–487.
Yoshida, O., and Dyke, S. J. (2004). “Seismic control of a nonlinear benchmark building using smart dampers.” J. Eng. Mech., 130(4), 386–392.
Information & Authors
Information
Published In
Copyright
© 2006 ASCE.
History
Received: Sep 21, 2004
Accepted: Jul 14, 2005
Published online: Jul 1, 2006
Published in print: Jul 2006
Notes
Note. Associate Editor: Raimondo Betti
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.