Use of ORP for Monitoring and Control of Aerobic Sludge Digestion
Publication: Journal of Environmental Engineering
Volume 116, Issue 3
Abstract
The oxidation‐reduction potential (ORP) was monitored within aerobic sludge digesters undergoing alternating aerated and nonaerated conditions. Observations were made on both bench‐scale and pilot‐scale reactors. Batch tests were also conducted on both reactors, involving a time series of chemical analyses, in conjunction with automated monitoring of reactor ORP and dissolved oxygen. The results indicated that a characteristic and reproducible ORP profile was associated with the cycled operation of the digesters. These real‐time ORP profiles had a number of distinctive features, directly related to changes in system chemistry and biological activity. The ranges of aerobic and anoxic respiration, as well as fermentation, were clearly defined by slope changes on the ORP profile. They also corresponded to the presence of the appropriate electron acceptors. The transition between the different ORP ranges was observed to be quite different during reaeration and deaeration. ORP was related to low levels of dissolved oxygen and nitrate. The data indicated that ORP could be used to measure very low oxygen concentrations. The reproducibility of the ORP profiles and sensitivity of the measured potential, to changes in biological or chemical activity, appears to make it an ideal parameter for automated monitoring and process control.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Ishizaki, A., Shibai, H., and Hirose, Y. (1974). “Basic aspects of electrode potential change in submerged fermentation.” J. of Agric. and Biological Chemistry, 38(12), 2399–2406.
2.
Jenkins, C. J., and Mavinic, D. S. (1989a). “Anoxic‐aerobic digestion of waste activated sludge: Part I—Solids reduction and digested sludge characteristics.” Envir. Tech. Letters, 10(4), 355–370.
3.
Jenkins, C. J., and Mavinic, D. S. (1989b). “Anoxic‐aerobic digestion of waste activated sludge: Part II—Supernatant characteristics, ORP monitoring results and overall rating system.” Envir. Tech. Letters, 10(4), 371–384.
4.
Kjaergaard, L. (1977). “The redox potential: Its use and control in biotechnology.” Advances in biochemical engineering, T. K. Ghose, A. Fiechter, and N. Blakebrough, eds., Springer‐Verlag, New York, N.Y.
5.
Koch, F. A., and Oldham, W. K. (1985). “ORP—A tool for monitoring, control and optimization of biological nutrient removal systems.” Water Sci. and Tech., 17, Paris, France, 259–281.
6.
Peddie, C. C., and Mavinic, D. S. (1990). “A pilot scale evaluation of aerobic/anoxic sludge digestion.” Canadian J. Civ. Engrg., 10(1), 68–78.
7.
Radjai, M., Hatch, R. T., and Cadman, T. W. (1984). “Optimization of amino acid production by automatic self‐tuning digital control of redox potential.” Biotech. and Bioengrg. Symp., No. 14, John Wiley and Sons, Inc., New York, N.Y.
8.
Sawyer, C. N., and McCarty, P. L. (1978). Chemistry for Envir. Engrg., McGraw‐Hill Book Company, New York, N.Y.
9.
Sekine, T., et al. (1985). “Advanced control strategies for the activated sludge process.” Proc., Instrumentation and Control of Water and Wastewater Treatment and Transportation Systems, International Association of Water Pollution Research and Control (IAWPRC) Workshop, Houston and Denver, R. A. R. Drake, ed., Pergamon Press, London, England.
10.
Shibai, H., et al. (1974). “Simultaneous measurement of dissolved oxygen and oxidation—Reproduction potentials in the aerobic culture.” J. Agric. and Biological Chemistry, 38(12), 2407–2411.
11.
Standard methods for the examination of water and wastewater. (1985). 16th Ed., American Public Health Assoc., Washington, D.C.
Information & Authors
Information
Published In
Copyright
Copyright © 1990 ASCE.
History
Published online: May 1, 1990
Published in print: May 1990
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.