Abstract

Vertical protruding elements are popularly used for building aesthetics, solar shading, and reduction of energy demand. However, no sufficient design guidelines are available yet for wind loading on curtain walls, especially those with vertical protrusions. In addition, water intrusion tests carried out by curtain wall manufacturers use static or pseudo-dynamic wind loads according to available testing manuals which are not realistic to simulate extreme wind and wind-driven rain conditions. This study investigates the influence of vertical protruding elements on the overall wind actions on a single skin façade using full-scale testing. The results show that vertical protrusions can increase the pressure around the protrusions and the wall (as evidenced by increased pressure coefficients) by as much as 30% and 19%, respectively. Furthermore, the vertical protrusions used in this study increased the overall stiffness of the curtain wall system, which led to an increase in the vibration of the glass units. Wind-driven rainwater intrusion tests on a façade unit without vertical protrusions indicate an increase in water penetration with wind speed at vulnerable joints (i.e., joints with windows) and less than 5 mL at the non-vulnerable joint at all wind speeds tested.

Get full access to this article

View all available purchase options and get full access to this article.

Acknowledgments

These tests were conducted at the NHERI Wall of Wind Experimental Facility (National Science Foundation Award No. 1520853 and No. 2037899). This paper is based upon work sponsored by the US National Science Foundation under the awards NSF IIP1841503,1841523 and I/UCRC Wind Hazard and Infrastructure Performance #2019-04. The authors also would like to thank Permasteelisa group for providing the curtain wall and curtain wall fixers. The authors also appreciate Roy-Liu Marques, James Erwin, and Walter Conklin for their support in instrumenting the model specimen. The opinions, findings, conclusions, or recommendations expressed in this article are solely those of the authors and do not represent the opinions of the funding agencies.

References

AAMA (American Architectural Manufacturers Association). 2005. Standard test method for water intrusion of windows, curtain walls and doors using dynamic pressure. AAMA 501.1-05. Schaumburg, IL: AAMA.
ASCE. 2016. Minimum design loads for buildings and other structures. ASCE 7-16. Reston, VA: ASCE.
ASTM. 2009. Standard test method for field determination of water intrusion of exterior windows, skylights, doors, and curtain walls by uniform or cyclic static Air pressure difference, 1–5. ASTM E1105-15, 00(Reapproved). West Conshohocken, PA: ASTM.
ASTM. 2016a. Standard test method for water intrusion of exterior windows, skylights, doors, and curtain walls by uniform static air pressure difference, 1–5. ASTM E331-00, 00(Reapproved). West Conshohocken, PA: ASTM.
ASTM. 2016b. Standard test method for water intrusion of exterior windows, skylights, doors, and curtain walls by uniform static air pressure. ASTM E547-00. West Conshohocken, PA: ASTM.
Azzi, Z., F. Habte, K. S. Vutukuru, A. G. Chowdhury, and M. Moravej. 2020. “Effects of roof geometric details on aerodynamic performance of standing seam metal roofs.” Eng. Struct. 225: 111303. https://doi.org/10.1016/j.engstruct.2020.111303.
Baheru, T., A. Gan Chowdhury, G. Bitsuamlak, F. J. Masters, and A. Tokay. 2014. “Simulation of wind-driven rain associated with tropical storms and hurricanes using the 12-fan wall of wind.” Build. Environ. 76: 18–29. https://doi.org/10.1016/j.buildenv.2014.03.002.
Baskaran, B. A., and W. C. Brown. 1995. “Dynamic evaluation of the building envelope for wind and wind-driven rain performance.” J. Therm. Insul. Build. Envelopes 18: 261–275. https://journals.sagepub.com/doi/pdf/10.1177/109719639501800306.
Blocken, B., and J. Carmeliet. 2004. “A review of wind-driven rain research in building science.” J. Wind Eng. Ind. Aerodyn. 92 (13): 1079–1130. https://doi.org/10.1016/j.jweia.2004.06.003.
Cain, J. H., D. Banks, and C. P. Petersen. 2015. “Wind Loads on Utility Scale Solar PV Power Plants.” In Proc., of SEAOC Convention. Sacramento, CA: Structural Engineers Association of California.
CEN (European Committee for Standardization). 2000. Curtain walling - Watertightness - Laboratory test under static pressure. EN 12155:2000. Brussels, Belgium: CEN.
CEN (European Committee for Standardization). 2001a. Hygrothermal performance of building components and building elements — determination of the resistance of external wall systems to driving rain under pulsating air pressure. EN 12865. Brussels, Belgium: CEN.
CEN (European Committee for Standardization). 2001b. Curtain walling — Watertightness — Site test. EN 13051. Brussels, Belgium: CEN.
CEN (European Committee for Standardization). 2011a. Actions on structures part 1–4: General actions — Wind actions. Eurocode 1, EN 1991-1-4:2005+A1:2010. Brussels, Belgium: CEN.
CEN (European Committee for Standardization). 2011b. Curtain walling — Watertightness — Laboratory test under dynamic condition of air pressure and water spray. EN 13050:2011. Brussels, Belgium: CEN.
Chand, I., and P. K. Bhargava. 1997. “Laboratory studies on the effect of external protrusions on wind pressure distribution on low-rise buildings.” Archit. Sci. Rev. 40 (4): 133–137. https://doi.org/10.1080/00038628.1997.9696823.
Chang, M., and S. Pakzad. 2014. “Observer Kalman filter identification for output-only systems using interactive structural modal identification toolsuite.” J. Bridge Eng. 19 (5): 04014002. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000530.
Cho, J., C. Yoo, and Y. Kim. 2014. “Viability of exterior shading devices for high-rise residential buildings: Case study for cooling energy saving and economic feasibility analysis.” Energy Build. 82: 771–785. https://doi.org/10.1016/j.enbuild.2014.07.092.
Choi, E. C. C. 1993. “Simulation of wind-driven-rain around a building.” In Proc., 1st Int. Symp. on Computational Wind Engineering, edited by S. Murakami, 721–729. Amsterdam, The Netherlands: Elsevier.
Choi, E. C. C. 2008. “The effect of wind-driven rain on cladding pressure of buildings under wind and rain conditions.” In Proc., BBAA VI Int. Colloquium on Bluff Bodies Aerodynamics and Applications, 1–4. Milano, Italy: BBAA. http://bbaa6.mecc.polimi.it/uploads/abstract_files/NB05_STAMPA5.pdf.
Chowdhury, A. G., K. S. Vutukuru, and M. Moravej. 2018. “Full- and large-scale experimentation using the wall of wind to mitigate wind loading and rain impacts on buildings and infrastructure systems.” In Proc., 11th Structural Engineering Convention. New Delhi, India: Indian Association for Structural Engineering. http://www.iastructe.co.in/.
Chowdhury, A. G., I. Zisis, P. Irwin, G. Bitsuamlak, J. P. Pinelli, B. Hajra, and M. Moravej. 2017. “Large-scale experimentation using the 12-fan wall of wind to assess and mitigate hurricane wind and rain impacts on buildings and infrastructure systems.” J. Struct. Eng. 143 (7): 04017053. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001785.
Cornick, S. M., and M. A. Lacasse. 2005. “A review of climate loads relevant to assessing the watertightness performance of walls, windows, and wall-window interfaces.” J. ASTM Int. 2 (10): 1–16. https://doi.org/10.1520/JAI12505.
Derome, D., A. Kubilay, T. Defraeye, B. Blocken, and J. Carmeliet. 2017. “Ten questions concerning modeling of wind-driven rain in the built environment.” Build. Environ. 114: 495–506. https://doi.org/10.1016/J.BUILDENV.2016.12.026.
Durst, C. S. 1960. “Wind speeds over short periods of time.” Meteorol. Mag. 89: 181–187.
Elawady, A., H. Aboshosha, A. El Damatty, G. Bitsuamlak, and H. Hangan. 2017. “Aero-elastic testing of multi-spanned transmission line subjected to downbursts.” J. Wind Eng. Ind. Aerodyn. 169: 194–216. https://doi.org/10.1016/j.jweia.2017.07.010.
ESDU (Engineering Sciences Data Unit). 2001. Characteristics of the atmospheric boundary layer, Part II: Single point data for strong winds (neutral atmosphere), ESDU Item 85020. London: ESDU.
Estephan, A., A. G. Chowdhury, and P. Irwin. 2021. “A new experimental-numerical approach to estimate peak wind loads on roof-mounted photovoltaic systems by incorporating inflow turbulence and dynamic effects.” Eng. Struct. 252: 113739. https://doi.org/10.1016/j.engstruct.2021.113739.
Evangelisti, L., C. Guattari, F. Asdrubali, and R. de Lieto Vollaro. 2020. “An experimental investigation of the thermal performance of a building solar shading device.” J. Build. Eng. 28: 101089. https://doi.org/10.1016/j.jobe.2019.101089.
FEMA. 2005. Vol. 488 of Hurricane Charley in Florida: observations, recommendations, and technical guidance, 1–24. Washington, DC: FEMA.
FEMA. 2006. Hurricane Katrina in the Gulf Coast (FEMA 549), Washington, DC: Federal Emergency Management Agency (FEMA).
Fronstin, P., and A. G. Holtmann. 1994. “The determinants of residential property damage caused by Hurricane Andrew.” J. South. Econ., 61 (2): 387–397. https://doi.org/10.2307/1059986.
Gierson, M. L., B. M. Phillips, and D. Duthinh. 2015. “Evaluation of ASCE 7-10 wind velocity pressure coefficients on the components and cladding of low-rise buildings using recent wind tunnel testing data.” In Proc., 6th Int. Conf. on Advances in Experimental Structural Engineering, 11th Int. Workshop on Advanced Smart Materials and Smart Structural Technology. Urbana, IL: University of Illinois, Urbana-Champaign. http://sstl.cee.illinois.edu/papers/aeseancrisst15/189_Gierson_Evaluation.pdf.
Guha, T. K., R. N. Sharma, and P. J. Richards. 2011. “Internal pressure dynamics of a leaky building with a dominant opening.” J. Wind Eng. Ind. Aerodyn. 99: 1151–1161. https://doi.org/http://doi.org/10.1016/j.jweia.2011.09.002.
Habte, F., M. Asghari Mooneghi, A. Gan Chowdhury, and P. Irwin. 2015. “Full-scale testing to evaluate the performance of standing seam metal roofs under simulated wind loading.” Eng. Struct. 105: 231–248. https://doi.org/10.1016/j.engstruct.2015.10.006.
ICC (International Code Council). 2017a. Testing application standard (TAS) 202-94 criteria for testing impact and nonimpact resistant building envelope components using uniform static air pressure. 2017 Florida Building Code—Test Protocols for High Velocity Hurricane Zone, 978-1-60983-688-7. Wasington, DC: ICC.
ICC (International Code Council). 2017b. Testing application standard (TAS) 203-94 criteria for testing products subject to cyclic wind pressure loading. 2017 Florida Building Code—Test Protocols for High Velocity Hurricane Zone, 978-1-60983-688-7. Washington, DC: ICC.
Irwin, H. P. A. H., K. R. Cooper, and R. Girard. 1979. “Correction of distortion effects caused by tubing systems in measurements of fluctuating pressures.” J. Wind Eng. Ind. Aerodyn. 5 (1): 93–107. https://doi.org/https://doi.org/10.1016/0167-6105(79)90026-6.
Kubilay, A., D. Derome, B. Blocken, and J. Carmeliet. 2015. “Wind-driven rain on two parallel wide buildings: Field measurements and CFD simulations.” J. Wind Eng. Ind. Aerodyn. 146: 11–28. https://doi.org/10.1016/j.jweia.2015.07.006.
Liu, J., Y. Hui, Q. Yang, and Y. Tamura. 2020. “Flow field investigation for aerodynamic effects of surface mounted ribs on square-sectioned high-rise buildings.” J. Wind Eng. Ind. Aerodyn. 211: 104551. https://doi.org/10.1016/j.jweia.2021.104551.
Liu, M., Q. Sheng, and S. Hong. 2019. “Large eddy simulation of wind-driven rain effects on a large span retractable roof stadium.” J. Wind Eng. Ind. Aerodyn. 195: 104009. https://doi.org/10.1016/j.jweia.2019.104009.
Mandalaki, M., K. Zervas, T. Tsoutsos, and A. Vazakas. 2012. “Assessment of fixed shading devices with integrated PV for efficient energy use.” Sol Energy 86 (9): 2561–2575. https://doi.org/http://dx.doi.org/10.1016/j.solener.2012.05.026.
Maruta, E., M. Kanda, and J. Sato. 1998. “Effects on surface roughness for wind pressure on glass and cladding of buildings.” J. Wind Eng. Ind. Aerodyn. 74–76: 651–663. https://doi.org/10.1016/S0167-6105(98)00059-2.
Mooneghi, A. M., P. Irwin, and A. Gan Chowdhury. 2016. “Partial turbulence simulation method for predicting peak wind loads on small structures and building appurtenances.” J. Wind Eng. Ind. Aerodyn. 157: 47–62. https://doi.org/10.1016/j.jweia.2016.08.003.
Moravej, M. 2018. “Investigating scale effects on analytical methods of predicting peak wind loads on buildings.” Ph.D. thesis, Dept. of Civil and Environmental Engineering, Florida International Univ. https://digitalcommons.fiu.edu/etd/3799.
Moravej, M., A. G. Chowdhury, P. Irwin, I. Zisis, and G. Bitsuamlak. 2015. “Dynamic effects of wind loading on photovoltaic systems.” In Proc., of 14th Int. Conf. on Wind Engineering. Tokyo, Japan: International Association for Wind Engineering. https://www.icwe14.org/.
Naeiji, A. 2017. “Wind loads on residential rooftop solar photovoltaic panels.” Ph.D. thesis, Dept. of Civil and Environmental Engineering, Florida International Univ.
Nakagami, Y. 2003. “Probabilistic dynamics of wind excitation on glass façade.” Ph.D. thesis, Dept. of Civil Engineering and Geodesy, Technische Universität Darmstadt. http://elib.tu-darmstadt.de/diss/000343.
NOAA National Centers for Environmental Information (NCEI). 2019. “Billion-dollar weather and climate disasters.” Accessed July 12, 2019. https://www.ncdc.noaa.gov/billions/events/US/1980-2019.
Orr, S. A., and H. Viles. 2018. “Characterisation of building exposure to wind-driven rain in the UK and evaluation of current standards.” J. Wind Eng. Ind. Aerodyn. 180: 88–97. https://doi.org/10.1016/J.JWEIA.2018.07.013.
Pariafsai, F. 2016. “A review of design considerations in glass buildings.” Front. Archit. Res. 5 (2): 171–193. https://doi.org/10.1016/j.foar.2016.01.006.
Pérez-Bella, J. M., J. Domínguez-Hernández, B. Rodríguez-Soria, J. J. del Coz-Díaz, E. Cano-Suñén, and A. Navarro-Manso. 2013. “An extended method for comparing watertightness tests for facades.” Build. Res. Inf. 41 (6): 706–721. https://doi.org/10.1080/09613218.2013.823538.
Rofail, A. W., and K. C. S. Kwok. 1999. “The effect of sunshading elements on cladding pressures.” In Proc., 10th Int. Conf. on Wind Engineering. Tokyo, Japan: International Association for Wind Engineering.
Sayed, M. A. A. E. D. A., and M. A. Fikry. 2019. “Impact of glass facades on internal environment of buildings in hot arid zone.” Alexandria Eng. J. 58 (3): 1063–1075. https://doi.org/10.1016/j.aej.2019.09.009.
Stathopoulos, T., and X. Zhu. 1990. “Wind pressures on buildings with mullions.” J. Struct. Eng. 116 (8): 2272–2291. https://doi.org/10.1061/(asce)0733-9445(1990)116:8(2272).
Strobel, K., and D. Banks. 2014. “Effects of vortex shedding in arrays of long inclined flat plates and ramifications for ground-mounted photovoltaic arrays.” J. Wind Eng. Ind. Aerodyn. 133: 146–149. https://doi.org/10.1016/j.jweia.2014.06.013.
St. Pierre, L. M., G. A. Kopp, D. Surry, and T. C. E. Ho. 2005. “The UWO contribution to the NIST aerodynamic database for wind loads on low buildings: Part 2. Comparison of data with wind load provisions.” J. Wind Eng. Ind. Aerodyn. 93 (1): 31–59. https://doi.org/10.1016/j.jweia.2004.07.007.
Taniike, Y. 1992. “Interference mechanism for enhanced wind forces on neighboring tall buildings.” J. Wind Eng. Ind. Aerodyn. 43 (1-3): 1073–1083. https://doi.org/10.1016/0167-6105(92)90114-P.
Tokay, A., P. G. Bashor, E. Habib, and T. Kasparis. 2008. “Raindrop size distribution measurements in tropical cyclones.” Mon. Weather Rev. 136 (5): 1669–1685. https://doi.org/10.1175/2007MWR2122.1.
Tokay, A., W. A. Petersen, P. Gatlin, and M. Wingo. 2013. “Comparison of raindrop size distribution measurements by collocated disdrometers.” J. Atmos. Ocean 30 (8): 1672–1690. https://doi.org/10.1175/JTECH-D-12-00163.1.
Van Den Bossche, N., M. A. Lacasse, and A. Janssens. 2013a. “A uniform methodology to establish test parameters for watertightness testing. Part I: A critical review.” Build Environ. 63: 145–156. https://doi.org/10.1016/j.buildenv.2012.12.003.
Van Den Bossche, N., M. A. Lacasse, and A. Janssens. 2013b. “A uniform methodology to establish test parameters for watertightness testing part II: Pareto front analysis on co-occurring rain and wind.” Build Environ. 63: 157–167. https://doi.org/10.1016/j.buildenv.2012.12.019.
Vutukuru, K. S., K. J. Alawode, A. Bakhtiari, A. Elawady, S. J. Lee, A. G. Chowdhury, and G. Lori. 2021. “Full-scale experimental testing to investigate wind-induced vibrations on curtain wall systems.” In Proc., 11th Int. Structural Engineering and Convention, edited by S. El Baradei, A. Abodonya, A. Singh, and S. Yazdani. Fargo, ND: ISEC Press.
Vutukuru, K. S., M. Moravej, A. Elawady, and A. G. Chowdhury. 2020. “Holistic testing to determine quantitative wind-driven rain intrusion for shuttered and impact resistant window.” J. Wind Eng. Ind. Aerodyn. 206: 104359. https://doi.org/10.1016/j.jweia.2020.104359.
Yang, Q., Z. Liu, Y. Hui, and Z. Li. 2020. “Modification of aerodynamic force characteristics on high-rise buildings with arrangement of vertical plates.” J. Wind Eng. Ind. Aerodyn. 200: 104155. https://doi.org/10.1016/j.jweia.2020.104155.
Yu, Y., T. Liu, Q. Zhang, and B. Yang. 2017. “Wind-induced response of an L-shaped cable support glass curtain wall.” Shock Vib. 2017: 4163045. https://doi.org/10.1155/2017/4163045.
Yuan, K., Y. Hui, and Z. Chen. 2018. “Effects of facade appurtenances on the local pressure of high-rise building.” J. Wind Eng. Ind. Aerodyn. 178: 26–37. https://doi.org/10.1016/j.jweia.2018.05.004.
Zheng, J., Q. Tao, and L. Li. 2020. “Wind pressure coefficient on a multi-storey building with external shading louvers.” Appl. Sci. 10 (3): 1128. https://doi.org/10.3390/app10031128.
Zhengnong, L., L. Diefeng, S. Wenhai, L. Zhiqi, and L. Xiaohan. 2011. “Field measurement of wind-induced stress on glass facade of a coastal high-rise building.” Sci. China Technol. Sci. 54 (10): 2587–2596. https://doi.org/10.1007/s11431-011-4512-z.

Information & Authors

Information

Published In

Go to Journal of Architectural Engineering
Journal of Architectural Engineering
Volume 29Issue 2June 2023

History

Received: Oct 30, 2021
Accepted: Oct 31, 2022
Published online: Jan 18, 2023
Published in print: Jun 1, 2023
Discussion open until: Jun 18, 2023

Permissions

Request permissions for this article.

Authors

Affiliations

Ph.D. Candidate, Dept. of Civil and Environmental Engineering, Florida International Univ., Miami, FL 33174. ORCID: https://orcid.org/0000-0003-0281-7789. Email: [email protected]
Senior Engineer, Thornton Tomasetti, Fort Lauderdale, FL 33301. ORCID: https://orcid.org/0000-0002-5587-5045. Email: [email protected]
Assistant Professor, Dept. of Civil and Environmental Engineering, Florida International Univ., Miami, FL 33174 (corresponding author). ORCID: https://orcid.org/0000-0003-4927-0709. Email: [email protected]
Associate Professor, Dept. of Civil and Environmental Engineering, Florida International Univ., Miami, FL 33174. ORCID: https://orcid.org/0000-0002-2180-3502. Email: [email protected]
Arindam Gan Chowdhury, Ph.D. [email protected]
Professor, Dept. of Civil and Environmental Engineering, Florida International Univ., Miami, FL 33174. Email: [email protected]
Guido Lori, Ph.D. [email protected]
Group Innovation and Technology, Permasteelisa S.p.A, Vittorio Veneto, Treviso, Italy. Email: [email protected]

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share