A Study of Laterally Loaded Piles after Failure
Publication: Geo-Congress 2024
ABSTRACT
Lateral large-scale testing of two pile specimens with a diameter of 0.46 m and a total length of 4.57 m was performed up to complete structural failure. The piles were embedded in 1.83 m of loose backfill sand with a relative density of 20%. At the tip, the piles were embedded in 1.22 m of simulated rock. Pile yield occurred at a lateral pile head displacement of 6.35 cm. The piles reached an ultimate capacity (Pult) near 72 kN at a corresponding pile head displacement of 20 cm. Post-test soil excavation around the piles was used to document pile damage and crack propagation. The originally predicted shear failure did not occur; rather, a flexure-triggered failure through the formation of a plastic hinge above the rock-socket was observed. Upon failure investigation, soil material was placed back into the excavation, and additional soil was placed with the same technique to raise the fill height above the rock socket from 1.83 to 3.05 m. The unique test setup allowed for re-testing of the damaged pile specimen, which is rarely possible in practice. Important understanding can be drawn from the test repetition: (1) magnitude of residual capacity of the damaged pile, (2) assessment of soil resistance independent of the pile as the pile was previously loaded to failure, and (3) evaluation of potential retrofit or repair strategies upon partial or full loss of structural pile integrity. Retesting with 64% more soil compared to the original soil thickness provided an additional 80% capacity compared to Pult of the damaged specimen.
Get full access to this article
View all available purchase options and get full access to this chapter.
REFERENCES
ASCE. (2017). Seismic evaluation and retrofit of existing buildings, ASCE/SEI 41-17, Reston, VA.
ASTM. ASTM C39/C39M-21. Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens, ASTM International, West Conshohocken, PA, 2021.
ASTM. ASTM D3080/D3080M-11. (2011). Standard Test Method for Direct Shear Test of Soils Under Consolidated Drained Conditions. ASTM International, West Conshohocken, PA.
ASTM. ASTM D1557-12e1. (2012). Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort. ASTM International, West Conshohocken, PA.
Budek, A., Benzoni, G., and Priestley, M. J. (1994). In-Ground Plastic Hinges in Column/Pile Shaft Design. Proceedings, 3rd Annual Caltrans Seismic Research Workshop. Caltrans.
Priestley, M. J., Seible, F., and Calvi, G. M. (1996). Seismic Design and Retrofit of Brdiges. New York: John Wilen and Sonces, Inc.
Chai, Y. H., and Hutchinson, T. C. (2002). “Flexural Strength and Ductility of Extended Pile-Shafts - Experimental Study”, Journal of Structural Engineering, ASCE, 128(5), pp. 595–602.
Farrag, R., Cox, C., Turner, B., and Lemnitzer, A. (2020). Shear demands of rock-socketed piles subject to cyclic lateral loading. DFI Journal, Vol. 14, No. 2.