Structures Congress 2020
Characterization of Corrosion in PS Concrete Girders by Correlation Analysis
Publication: Structures Congress 2020
ABSTRACT
The magnetic flux leakage (MFL)-based assessment is used to detect corroded regions of steel prestressing strands in pre/post-stressed (PS) concrete girders. The MFL instrument includes two blocks of DC magnet to create a powerful magnetic field in the vicinity of the steel within the concrete girder. Hall-effect sensors are used to acquire the resulting magnetic field signals in the vertical and longitudinal directions while the MFL instrument is moved along the length of the girder. To characterize corrosion-related signals, a correlation-based analysis is implemented. This approach helped to identify the position and intensity of the corrosion in the steel. Using the correlation analysis with an idealized corrosion signal, the effects of other steel in PS concrete girders, including the conventional shear reinforcement, are removed from the test signal. An approximate percentage of section loss and length of corroded regions are estimated using this signal analysis.
Get full access to this article
View all available purchase options and get full access to this chapter.
REFERENCES
Kordijazi, A. (2019). Optimization of Ni-P-Zn electroless bath and investigation of corrosion resistance of as-plated coatings. Materials Research Express, 6. https://doi.org/10.1088/2053-1591/ab2a68
Antipov, A., Markov, A. (2014). Evaluation of transverse cracks detection depth in MFL rail NDT. Russian Journal of Nondestructive Testing, 50(8), 481-490.
Elyasigorji, A., Rezaee, M., Ghprbanpoor, A. (2019). Magnetic Corrosion Detection in Concrete Structures. ASCE International Conference on Sustainable Infrastructure 2019.Los angeles: ASCE.
Ghorbanpoor, A., Borchelt, R., Edwards, M., Abdel Salem, E. (2000). MAGNETIC-BASED NDE OF PRESTRESSED AND POST-TENSIONED CONCRETE MEMBERS - THE MFL SYSTEM. McLean: Federal Highway Administration.
Kamaitis, Z. (2002). DAMAGE TO CONCRETE BRIDGES DUE TO REINFORCEMENT CORROSION. Transport, 17:4, 137-142.
Lei, H., Tian, G. (2013). Broken wire detection in coated steel belts using the magnetic flux leakage method. Insight: Non-Destructive Testing and Condition Monitoring, 55(3), 126-131.
Mehrabi, A. (2006). In-Service Evaluation of Cable-Stayed Bridges, Overview of Available Methods and Findings. Journal of Bridge Engineering, 11(6), 716-724.
Park, S., Kim, J.-W., Lee, J.-J. (2014). Magnetic Flux Leakage Sensing-Based Steel Cable NDE Technique. Shock and Vibration, 1-8. Retrieved from http://www.hindawi.com/journals/sv/2014/929341/
Permeh, S., Vigneshwaran, K., Lau, K.(2016). CORROSION OF POST-TENSIONED TENDONS WITH DEFICIENT GROUT. Florida Department of Transportation, State Materials Office. Gainesville, FL 32609: FDOT Research Center.
Sawadw, G., Krause, H.-J. (2010). Magnetic fl ux leakage (MFL) for the non- destructive evaluation of pre-stressed concrete structures. Non-destructive evaluation of reinforced concrete structures.
Xu, F., Wang, X., Wu, H. (2012). Inspection method of cable-stayed bridge using magnetic flux leakage detection: principle, sensor design, and signal processing. Journal of Mechanical Science and Technology, 26(3), 661-669.
Information & Authors
Information
Published In
ISBN (Online): 978-0-7844-8289-6
Copyright
© 2020 American Society of Civil Engineers.
History
Published online: Apr 2, 2020
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.