Learning from Failure of a Long Curved Veneer Wall: Structural Analysis and Repair
This article has a reply.
VIEW THE REPLYPublication: Journal of Performance of Constructed Facilities
Volume 27, Issue 1
Abstract
Masonry remains the most used material for enclosure and partition walls. However, cracking often occurs in unreinforced masonry walls under service conditions, and little information can be found about systemic approaches in real case studies. Here, attention is given to a large building faced with a fired clay brick masonry veneer that exhibited significant out-of-plane movements only 1.5 years after construction. During the operation of dismounting part of the veneer, partial collapse occurred. The veneer wall, with an elliptical shape, 240 m length and 15 m height, presented no movement joints and insufficient tying. Irreversible expansion of the fired clay brick masonry was expected to be the main reason for the damage. The combination of inspection work (visual inspection, pull-out tests, and topographic survey) and advanced structural analysis with finite elements allowed an understanding of the damage and a repair solution at a fraction of the cost of demolishing and rebuilding a new veneer.
Get full access to this article
View all available purchase options and get full access to this article.
References
Association of Mutual Insurance of Higher Architects (ASEMAS). (1997). Façade enclosures: A badly understood building process (in Spanish), Bulletin 13, Madrid, Spain.
ASTM. (2003). “Standard test methods for strength of anchors in concrete elements.” E488-96, Conshohocken, PA.
Bezelga, A. A. (1984). Housing building: Characterization and technical-economical estimation, Universidade Técnica de Lisboa-Imprensa Nacional-Casa da Moeda, Lisbon, Portugal (in Portuguese).
Brooks, J. J. (1990). “Composite modelling of masonry deformation.” Mater. Struct., 23(4), 241–251.
Bureau Securitas. (1984). “Statistical study of 12200 damage cases occurring in 1982.” Annales de l’ITBTP 426, Paris (in French).
Del Coz Díaz, J. J., Lozano Martínez-Luengas, A., Adam, J. M., and Martín Rodríguez, A. (2011). “Non-linear hygrothermal failure analysis of an external clay brick wall by FEM—A case study.” Construct. Build. Mater., 25(12), 4454–4464.
Dilrukshi, K. G. S., Dias, W. P. S., and Rajapakse, R. K. N. D. (2010). “Numerical modelling of cracks in masonry walls due to thermal movements in an overlying slab.” Eng. Struct., 32(5), 1411–1422.
European Committee for Standardization (CEN). (2000). “Methods of test for masonry units. Determination of moisture expansion of large horizontally perforated clay masonry units.” CEN, Brussels, Belgium.
European Committee for Standardization (CEN). (2003). “Actions on structures—Part 1–5: General actions—Thermal actions.” Eurocode 1, Brussels, Belgium.
European Committee for Standardization (CEN). (2005a). “Actions on structures—Part 1–4: General actions—Wind actions.” Eurocode 1, Brussels, Belgium.
European Committee for Standardization (CEN). (2005b). “Design of masonry structures—Part 1–1: General rules for reinforced and unreinforced masonry structures.” Eurocode 6, Brussels, Belgium.
European Committee for Standardization (CEN). (2006). “Design of masonry structures—Part 2: Design considerations, selection of materials and execution of masonry.” Eurocode 1, Brussels, Belgium.
Fathy, A. M., Planas, J., and Sancho, J. M. (2009). “A numerical study of masonry cracks.” Eng. Fail. Anal., 16(2), 675–689.
Lourenço, P. B., Medeiros, P., and Vasconcelos, G. (2009). “Damage in the veneer wall for the multipurpose hall in Gondomar. Diagnosis and solutions.” Rep. 09-DEC/E-01, Univ. of Minho, Guimarães, Portugal (in Portuguese).
Lourenço, P. B., Mendes, N., Ramos, L. F., and Oliveira, D. V. (2011). “Analysis of masonry structures without box behavior.” Int. J. Architect. Heritage, 5(4–5), 369–382.
Lourenço, P. B., and Rots, J. G. (1997), Multisurface interface model for the analysis of masonry structures, J. Eng. Mech., 123(7), 660–668.
Marques, R., and Lourenço, P. B. (2011). “Possibilities and comparison of structural component models for the seismic assessment of masonry buildings.” Comput. Struc., 89(21–22), 2079–2091.
Masonry Society. (2007). Masonry designer's guide, 5th Ed., Masonry Society, Longmont, CO.
Menezes R. R., Campos, L. F., Neves, G. A., and Ferreira, H. C. (2006). “Fundamental aspects of the moisture expansion: Review. Part II: Kinetic of expansion and its determination.” Cerâmica, 52, 114–124 (in Portuguese).
TNO Diana. (2009). Diana finite element analysis, user's manual—release 9.4. Delft, Netherlands.
Van Zijl, G. P. A. G., De Vries, P. A., and Vermeltfoort, A. T. (2004). “Masonry wall damage by restraint to shrinkage.” J. Struct. Eng., 130(7), 1075–1086.
Wilson, M. A., Hoff, W. D., Hall, C., McKay, B., and Hiley, A. (2003). “Kinetics of moisture expansion in fired clay ceramics: A (time)(1/4) law.” Phys. Rev. Lett., 90(12), 125503-1–125503-4.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: Aug 21, 2011
Accepted: Nov 2, 2011
Published online: Nov 4, 2011
Published in print: Feb 1, 2013
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.