A Large-Tonnage High-Strength CFRP Cable-Anchor System: Experimental Investigation and FE Study
Publication: Journal of Composites for Construction
Volume 26, Issue 5
Abstract
In this study, a parallel-tendon and dispersed-tendon cable anchor system (CAS) for high-strength carbon-fiber-reinforced polymer (CFRP) cables were investigated based on a previously developed load transfer component (LTC). The static behaviors of three cables comprising 37 CFRP tendons with a 7-mm tendon diameter were experimentally evaluated and the failure mechanism of the cables was numerically revealed. The parallel-tendon cable exhibited an integral pull-out failure caused by a shear failure of the LTC, while the dispersed-tendon cables showed a mixed shear and compressive failure caused by an excessive axial tensile strain difference and wedge action of the LTC. From loading end to free end, the shear stress of the LTC first increased rapidly, and then increased slowly with fluctuations, and finally peaked the free end. The experimental and numerical results agreed well in the axial cable strains and shear stresses of the LTC. By optimizing parallel tendons into dispersed tendons in the anchor zone, the anchor efficiency of the cable was improved from 60% to 91%. Correspondingly, the cable force was improved from 2,684 to 4,070 kN. The increase in the anchor length and decrease in the conical angle can decrease the stress concentration of the dispersed-tendon CAS.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The authors gratefully acknowledge the financial support provided by the Natural Science Foundation of Jiangsu Province (Grant No. BK20220855), the Excellent Postdoctoral Program of Jiangsu Province (Grant No. 2022ZB132), the National Key Research and Development Program of China (Grant No. 2019YFC1511100), and the Fundamental Research Funds for the Central Universities (Grant No. 2242022k30031 and 2242022k30033). The authors also acknowledge Jiangsu Green Materials Valley New Material T&D Co., Ltd. for providing CFRP tendons.
References
Ai, P., P. Feng, H. Lin, P. Zhu, and G. Ding. 2021. “Novel self-anchored CFRP cable system: Concept and anchorage behavior.” Compos. Struct. 263: 113736. https://doi.org/10.1016/j.compstruct.2021.113736.
Al-Mayah, A., K. A. Soudki, and A. Plumtree. 2001. “Experimental and analytical investigation of a stainless steel anchorage for CFRP prestressing tendons.” PCI J. 46 (2): 88–100. https://doi.org/10.15554/pcij.03012001.88.100.
Al-Mayah, A., K. Soudki, and A. Plumtree. 2006. “Development and assessment of a new CFRP rod-anchor system for prestressed concrete.” Appl. Compos. Mater. 13 (5): 321–334. https://doi.org/10.1007/s10443-006-9019-6.
Cai, H., and A. J. Aref. 2015. “A genetic algorithm-based multi-objective optimization for hybrid fiber reinforced polymeric deck and cable system of cable-stayed bridges.” Struct. Multidiscip. Optim. 52 (3): 583–594. https://doi.org/10.1007/s00158-015-1266-4.
Cao, S., Z. Wu, and X. Wang. 2009. “Tensile properties of CFRP and hybrid FRP composites at elevated temperatures.” J. Compos. Mater. 43 (4): 315–330. https://doi.org/10.1177/0021998308099224.
CS (Chinese Standard). 2013. Test method for basic mechanical properties of fiber reinforced polymer bar. GB/T 30022-2013. Beijing: CS.
CS (Chinese Standard). 2017. Fiber reinforced polymer composites structural cables. GB/T 35156-2017. Beijing: CS.
CS (Chinese Standard). 2018. Hot-extruded PE protection paralleled high strength wire cable for cable-stayed bridge. GB/T 18365-2018. Beijing: CS.
CS (Chinese Standard). 2020. Anchorage and grip for prestressing fiber-reinforced polymer. T/CECS 10112-2020. Beijing: CS.
Feng, B., X. Wang, and Z. Wu. 2019a. “Fatigue life assessment of FRP cable for long-span cable-stayed bridge.” Compos. Struct. 210: 159–166. https://doi.org/10.1016/j.compstruct.2018.11.039.
Feng, B., X. Wang, and Z. Wu. 2019b. “Static and fatigue behavior of multitendon CFRP cables with integrated anchorages.” J. Compos. Constr. 23 (6): 04019051. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000982.
Feng, B., J. Zhong, and H. Li. 2021. “An analytical research about parameter influence on large-scale anchorage region with multiple CFRP cables.” KSCE J. Civ. Eng. 25 (2): 540–551. https://doi.org/10.1007/s12205-020-2346-6.
Liu, Y., B. Zwingmann, and M. Schlaich. 2015. “Carbon fiber reinforced polymer for cable structures—A review.” Polymers 7 (10): 2078–2099. https://doi.org/10.3390/polym7101501.
Mei, K., R. Seracino, and Z. Lv. 2016. “An experimental study on bond-type anchorages for carbon fiber-reinforced polymer cables.” Constr. Build. Mater. 106: 584–591. https://doi.org/10.1016/j.conbuildmat.2015.12.059.
Meier, U., and M. Farshad. 1996. “Connecting high-performance carbon-fiber-reinforced polymer cables of suspension and cable-stayed bridges through the use of gradient materials.” J. Comput.-Aided Mater. Des. 3 (1–3): 379–384. https://doi.org/10.1007/BF01185676.
Noisternig, J. F. 2000. “Carbon fibre composites as stay cables for bridges.” Appl. Compos. Mater. 7 (2–3), 139–150. https://doi.org/10.1023/A:1008946132034.
Peng, Z., X. Ling-zhi, and M. M. S. Cheung. 2015. “Analysis and design procedure of hybrid long-span cable-stayed bridge using advanced composite material.” J. Reinf. Plast. Compos. 34 (19): 1557–1580. https://doi.org/10.1177/0731684415576259.
Schmidt, J. W., S. T. Smith, B. Taljsten, A. Bennitz, P. Goltermann, and H. Pedersen. 2011. “Numerical simulation and experimental validation of an integrated sleeve-wedge anchorage for CFRP rods.” J. Compos. Constr. 15 (3): 284–292. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000171.
Shi, J., X. Wang, L. Zhang, Z. Wu, and Z. Zhu. 2022. “Composite-wedge anchorage for fiber-reinforced polymer tendons.” J. Compos. Constr. 26 (2): 04022005. https://doi.org/10.1061/(ASCE)CC.1943-5614.0001194.
Wang, Q., H. Zhu, B. Zhang, Y. Tong, F. Teng, and W. Su. 2020a. “Anchorage systems for reinforced concrete structures strengthened with fiber-reinforced polymer composites: State-of-the-art review.” J. Reinf. Plast. Compos. 39 (9–10): 327–344. https://doi.org/10.1177/0731684420905010.
Wang, X., and Z. Wu. 2011. “Modal damping evaluation of hybrid FRP cable with smart dampers for long-span cable-stayed bridges.” Compos. Struct. 93 (4): 1231–1238. https://doi.org/10.1016/j.compstruct.2010.10.018.
Wang, X., P. Xu, Z. Wu, and J. Shi. 2015a. “A novel anchor method for multi-tendon FRP cable: Concept and FE study.” Compos. Struct. 120: 552–564. https://doi.org/10.1016/j.compstruct.2014.10.024.
Wang, X., P. Xu, Z. Wu, and J. Shi. 2015b. “A novel anchor method for multitendon FRP cable: Manufacturing and experimental study.” J. Compos. Constr. 19 (6): 04015010. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000563.
Wang, X., J. Zhou, L. Ding, J. Song, and Z. Wu. 2020b. “Static behavior of circumferential stress-releasing anchor for large-capacity FRP cable.” J. Bridge Eng. 25 (1): 04019114. https://doi.org/10.1061/(ASCE)BE.1943-5592.0001504.
Wu, J., G. Xian, and H. Li. 2018. “A novel anchorage system for CFRP cable: Experimental and numerical investigation.” Compos. Struct. 194: 555–563. https://doi.org/10.1016/j.compstruct.2018.04.006.
Xie, G., J. Yin, R. Liu, B. Chen, and D. Cai. 2017. “Experimental and numerical investigation on the static and dynamic behaviors of cable-stayed bridges with CFRP cables.” Composites, Part B 111: 235–242. https://doi.org/10.1016/j.compositesb.2016.11.048.
Yang, Y., M. F. M. Fahmy, S. Guan, Z. Pan, Y. Zhan, and T. Zhao. 2020a. “Properties and applications of FRP cable on long-span cable-supported bridges: A review.” Composites, Part B 190: 107934. https://doi.org/10.1016/j.compositesb.2020.107934.
Yang, Y., X. Wang, and Z. Wu. 2020b. “Long-span cable-stayed bridge with hybrid arrangement of FRP cables.” Compos. Struct. 237: 111966. https://doi.org/10.1016/j.compstruct.2020.111966.
Zhang, B., and B. Benmokrane. 2004. “Design and evaluation of a new bond-type anchorage system for fiber reinforced polymer tendons.” Can. J. Civ. Eng. 31 (1): 14–26. https://doi.org/10.1139/l03-062.
Zhang, K., Z. Fang, A. Nanni, J. Hu, and G. Chen. 2015. “Experimental study of a large-scale ground anchor system with FRP tendon and RPC grout medium.” J. Compos. Constr. 19 (4): 04014073. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000537.
Zhou, J., X. Wang, Z. Peng, Z. Wu, and X. Wei. 2022a. “Enhancement of FRP cable anchor system: Optimization of load transfer component and full-scale cable experiment.” J. Compos. Constr. 26 (2): 04022008. https://doi.org/10.1061/(ASCE)CC.1943-5614.0001196.
Zhou, J., X. Wang, Z. Peng, Z. Wu, and Z. Zhu. 2021. “Failure mechanism and optimization of fiber-reinforced polymer cable-anchor system based on 3D finite element model.” Eng. Struct. 243: 112664. https://doi.org/10.1016/j.engstruct.2021.112664.
Zhou, J., X. Wang, Z. Peng, Z. Wu, and Z. Zhu. 2022b. “Evaluation of a large-tonnage FRP cable anchor system: Anchorage design and full-scale experiment.” Eng. Struct. 251: 113551. https://doi.org/10.1016/j.engstruct.2021.113551.
Information & Authors
Information
Published In
Copyright
© 2022 American Society of Civil Engineers.
History
Received: Jan 25, 2022
Accepted: May 19, 2022
Published online: Jul 19, 2022
Published in print: Oct 1, 2022
Discussion open until: Dec 19, 2022
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.
Cited by
- Wenchao Zhang, Lijun Jia, Rucheng Xiao, Shanshan Yuan, Huiteng Pei, Experimental and Analytical Investigation into the Mechanical Performance of a Novel Multitendon CFRP Anchorage, Journal of Composites for Construction, 10.1061/JCCOF2.CCENG-4881, 28, 6, (2024).
- Lijun Jia, Yuchen Yang, Xiao Cong, Static Experimental Study on New Arc Multi-Tendon CFRP Cable Anchorage System, Buildings, 10.3390/buildings13030669, 13, 3, (669), (2023).
- Jingyang Zhou, Xin Wang, Lining Ding, Shui Liu, Zhishen Wu, Numerical and Experimental Study on Large-Diameter FRP Cable Anchoring System with Dispersed Tendons, Buildings, 10.3390/buildings13010092, 13, 1, (92), (2022).