Rectangular Filament-Wound Glass Fiber Reinforced Polymer Tubes Filled with Concrete under Flexural and Axial Loading: Analytical Modeling
This article is a reply.
VIEW THE ORIGINAL ARTICLEThis article has a reply.
VIEW THE REPLYPublication: Journal of Composites for Construction
Volume 9, Issue 1
Abstract
This paper presents an analytical model to predict the behavior of concrete-filled rectangular fiber reinforced polymer (FRP) tubes (CFRFTs), subjected to bending and axial loads. The model accounts for different laminate structures of the flange and web of the tube. Gradual reduction of stiffness, resulting from progressive failure of FRP layers oriented at various angles is considered through the ultimate laminate failure approach. The model adopts cracked section analysis, using layer-by-layer approach and accounts for totally and partially filled tubes. The model predicts the moment–curvature responses of beams, load–strain responses of columns, and complete interaction curves of beam–columns. The model is verified using experimental results and is used to study the effects of laminate structure, hybrid laminates, thickness of the tube and optimization of partially filled tubes. Comparisons of CFRFT with conventional reinforced concrete (RC) sections showed that CFRFT could provide axial load–bending moment interaction curves comparable to those of RC sections of similar reinforcement index. Also, providing a small fraction of carbon fibers in the flanges could substantially improve flexural performance. The first ply failure approach could highly underestimate the strength of CFRFT.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers wish to acknowledge financial support provided by the Network of Centres of Excellence on Intelligent Sensing for Innovative Structures (ISIS Canada), Queen’s University, and North Carolina State University.
References
American Concrete Institute (ACI). Committee 318 (1999). “Building code requirements for reinforced concrete and commentary.” ACI 318M-99/ACI 318RM-99, Detroit.
Burgueno, R., Davol, A., and Seible, F. (1998). “The carbon shell system for modular bridge components.” Proc., 2nd Int. Conf. on Composites in Infrastructure (ICCI’98), 341–354.
Collins, M. P., and Mitchell, D. (1997). Prestressed concrete structures, Response Publications, Canada.
Daniel, I. M., and Ishai, O. (1994). Engineering mechanics of composite materials, Oxford Univ. Press, New York.
Davol, A. (1998). “Structural characterization of concrete filled fiber reinforced shells.” PhD thesis, Univ. of California, San Diego.
Fam, A. Z. (2000). “Concrete-filled fiber reinforced polymer tubes for axial and flexural structural members.” PhD thesis, Univ. of Manitoba, Winnipeg, Canada.
Fam, A. Z., and Rizkalla, S. H. (2001). “Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes.” ACI Struct. J., 98(4), 451–461.
Fam, A. Z., and Rizkalla, S. H. (2002). “Flexural behavior of concrete-filled fiber reinforced polymer circular tubes.” J. Compos. Constr., 6(2), 123–132.
Fam, A., Flisak, B., and Rizkalla, S. (2003a). “Experimental and analytical modeling of concrete-filled fiber-reinforced polymer tubes subjected to combined bending and axial loads.” ACI Struct. J., 100(4), 1–11.
Fam, A., Pando, M., Filz, G., and Rizkalla, S. (2003b). “Precast piles for Route 40 bridge in Virginia using concrete filled FRP tubes.” PCI J., 48(3), 32–45.
Fam, A., Schnerch, D., and Rizkalla, S. (2005). “Rectangular filament-wound GFRP tubes filled with concrete under flexural and axial loading: Experimental investigation.” J. Compos. Constr., 9(1), 25–33.
Hognestad, E. (1951). “A study of combined bending and axial load in reinforced concrete members.” Bulletin No. 399, Univ. of Illinois Engineering Experimental Station, Champaign, Ill.
Mirmiran, A., Shahawy, M., and Samaan, M. (1999). “Strength and ductility of hybrid FRP-concrete beam-columns.” J. Struct. Eng., 125(10), 1085–1093.
Mirmiran, A., Shahawy, M., Samaan, M., Echary, H. E., Mastrapa, J. C., and Pico, O. (1998). “Effect of column parameter on FRP-confined concrete.” J. Compos. Constr., 2(4), 175–185.
Popovics, S. (1973). “A numerical approach to the complete stress-strain curve of concrete.” Cem. Concr. Res., 3(5), 583–599.
Richart, F. E., and Brown, R. L. (1934). “An investigation of reinforced concrete columns.” Bulletin No. 267, Univ. of Illinois Engineering Experimental Station, Champaign, Ill.
Rochette, P. (1996). “Confinement of short square and rectangular columns with composite materials.” MS thesis, Univ. of Sherbrooke, Quebec.
Saafi, M., Toutanji, H. A., and Li, Z. (1999). “Behavior of concrete columns confined with fiber reinforced polymer tubes.” ACI Mater. J., 96(4), 500–509.
Samaan, M., Mirmiran, A., and Shahawy, M. (1998). “Model of concrete confined by fiber composites.” J. Struct. Eng., 124(9), 1025–1031.
Seible, F. (1996). “Advanced composite materials for bridges in the 21st century.” Proc., 1st Int. Conf. on Composites in Infrastructure (ICCI’96), 17–30.
Spoelstra, M. R., and Monti, G. (1999). “FRP-confined concrete model.” J. Compos. Constr., 3(3), 143–150.
Information & Authors
Information
Published In
Copyright
© 2005 ASCE.
History
Received: Dec 3, 2003
Accepted: Jun 24, 2004
Published online: Feb 1, 2005
Published in print: Feb 2005
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.