Experimental Investigation of Beam–Column Joints with Cast Steel Stiffeners for Progressive Collapse Prevention
Publication: Journal of Structural Engineering
Volume 145, Issue 5
Abstract
A full-scale experimental study was carried out on a two-story steel frame to investigate the progressive collapse behavior of beam–column joints with cast steel stiffeners (CSS). The frame was divided into four vertical sections, and each section had a specific joint arrangement of (1) joints with CSS and (2) welded joints without stiffeners. Seven loads of increasing magnitude were applied to the frame. In each section, one of the columns had a device at the base that could be removed and replaced to simulate the failure and repair of this column; this column is referred to as an adjustable column. Strain changes and displacements were monitored during column removal. Moreover, three types of finite-element models were developed to simulate the test frame. The results showed that compared to a welded joint without stiffeners, joints with CSS reduced the strain change and deformation of the frame, as well as the dynamic strain magnification factor of strain change; concrete slabs played a significant role during the load redistribution in the sudden failure of the adjustable column.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research project is supported by the National Natural Science Foundation of China (No. 51525803), the National Postdoctoral Science Foundation of China (No. 2016M601262), and the China Scholarship Council (No. 201606250064). The support from the funding agency is gratefully appreciated.
References
ASCE. 2010. Minimum design loads for buildings and other structures. SEI/ASCE 7. Reston, VA: ASCE.
Chen, J., X. Huang, R. Ma, and M. He. 2012. “Experimental study on the progressive collapse resistance of a two-story steel moment frame.” J. Perform. Constr. Facil. 26 (5): 567–575. https://doi.org/10.1061/(ASCE)CF.1943-5509.0000287.
DoD (Department of Defense). 2009. Design of buildings to resist progressive collapse, unified facilities criteria (UFC). Washington, DC: DoD.
Faridmehr, I., Y. Ahmad, M. Tahir, and M. Osman. 2016. “Cyclic and explosive evaluation of new proposed steel joint.” Adv. Civ. Eng. 2016 (1): 4975097. https://doi.org/10.1155/2016/4975097.
Han, Q., M. Liu, and Y. Lu. 2015. “Mechanical behavior analysis of cast steel joints for H-shaped beam to square tube column.” [In Chinese.] J. Tianjin Univ. (Sci. Technol.) 48 (6): 502–509. https://doi.org/10.11784/tdxbz201405074.
Han, Q., M. Liu, Y. Lu, and S. Zhao. 2016. “Experimental and simulation study on seismic behavior of beam–column joints with cast steel stiffener.” J. Struct. Eng. 142 (7): 04016030. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001487.
Hitachi Metals Techno. 2001. Guide of design and construction of ‘HIBLADE process’ of Hitachi. Tokyo: Hitachi Metals Techno.
Johnson, E. S., J. E. Meissner, and L. A. Fahnestock. 2016. “Experimental behavior of a half-scale steel concrete composite floor system subjected to column removal scenarios.” J. Struct. Eng. 142 (2): 04015133. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001398.
Li, L., W. Wang, Y. Chen, and Y. Lu. 2013. “Experimental investigation of beam-to-tubular column moment connections under column removal scenario.” J. Constr. Steel Res. 88 (9): 244–255. https://doi.org/10.1016/j.jcsr.2013.05.017.
MCPRC (Ministry of Construction of the People’s Republic of China). 2003. Code for design of steel structures. [In Chinese.] GB 50017. Beijing: China Architecture & Building Press.
MCPRC (Ministry of Construction of the People’s Republic of China). 2015. Chinese technical specification for steel structure of tall building (TSSSTB). [In Chinese.] Beijing: China Architecture & Building Press.
Nakano, K., T. Kitano, K. Yoshinaga, and K. Ochi. 2003. “Development of ‘HIBLADE process’ with external stiffener rings using cast steel.” [In Japanese.] Hitachi Met. Tech. Rev. 19 (1): 67–70.
Qin, X., W. Wang, Y. Chen, and Y. Bao. 2016. “A special reinforcing technique to improve resistance of beam-to-tubular column connections for progressive collapse prevention.” Eng. Struct. 117 (6): 26–39. https://doi.org/10.1016/j.engstruct.2016.03.012.
Song, B. I., K. A. Giriunas, and H. Sezen. 2014. “Progressive collapse testing and analysis of a steel frame building.” J. Constr. Steel Res. 94 (3): 76–83. https://doi.org/10.1016/j.jcsr.2013.11.002.
Song, B. I., and H. Sezen. 2013. “Experimental and analytical progressive collapse assessment of a steel frame building.” Eng. Struct. 56 (9): 664–672. https://doi.org/10.1016/j.engstruct.2013.05.050.
Urgessa, G. S., and T. Arciszewski. 2011. “Blast response comparison of multiple steel frame connections.” Finite Elem. Anal. Des. 47 (7): 668–675. https://doi.org/10.1016/j.finel.2011.01.009.
Wang, W., C. Fang, X. Qin, Y. Chen, and L. Li. 2016. “Performance of practical beam-to-SHS column connections against progressive collapse.” Eng. Struct. 106 (1): 332–347. https://doi.org/10.1016/j.engstruct.2015.10.040.
Yang, B., and K. H. Tan. 2013. “Robustness of bolted-angle connections against progressive collapse: Mechanical modelling of bolted-angle connections under tension.” Eng. Struct. 57 (12): 153–168. https://doi.org/10.1016/j.engstruct.2013.08.041.
Information & Authors
Information
Published In
Copyright
©2019 American Society of Civil Engineers.
History
Received: Oct 16, 2017
Accepted: Oct 17, 2018
Published online: Feb 22, 2019
Published in print: May 1, 2019
Discussion open until: Jul 22, 2019
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.