Application of Local Reference-Free Damage Detection Techniques to In Situ Bridges
Publication: Journal of Structural Engineering
Volume 140, Issue 3
Abstract
There are increasing demands to apply structural health monitoring (SHM) techniques to bridge structures. To meet these demands, our group has developed a suite of local SHM techniques that can detect particular types of damage without using baseline data obtained from the pristine condition of a structure. They are coined as reference-free damage detection techniques. The main advantage of the reference-free techniques is that they can provide improved damage diagnosis even when the system being monitored is exposed to ambient variations such as external load and temperature changes. Since the reference-free techniques do not rely on a direct comparison with previously obtained baseline data, they are less vulnerable to false alarms due to undesirable variations which in-site structures are frequently subjected to. In this study, the applicability of two specific reference-free techniques to real bridge structures and associated implementation issues are examined through field tests of a decommissioned curved steel box girder bridge and an in-service single-span steel girder bridge in Korea. Our monitoring efforts are focused on detection of cracking in critical steel members with additional structural features such as stiffeners and diaphragms. External loading effects on the reference-free techniques are investigated through static and dynamic loading tests using a 35-t dump truck. Furthermore, daily/seasonal temperature variations are observed over a 1-year period. The test results confirm that the reference-free techniques successfully identify cracks on the test bridges even under varying external loading and temperature conditions. In addition, the long-term durability issues of piezoelectric transducers (PZTs) are addressed, and an enhanced PZT design has been proposed to improve the PZT durability.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This work was supported by a National Research Laboratory Program (2010-0017456) and the Nuclear Research & Development Program (2010-0020423) of the National Research Foundation of Korea. Also, the authors would like to express thanks to Korea Expressway Corporation. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the funding agencies.
References
An, Y.-K., and Sohn, H. (2010). “Instantaneous crack detection under varying temperature and static loading conditions.” Struct. Contr. Health Monit., 17(7), 730–741.
Anton, S. R., and Inman, D. J. (2009). “Reference-free damage detection using instantaneous baseline measurements.” AIAA J., 47(8), 1952–1964.
Brownjohn, J. M. W., Moyo, P., Omenzetter, P., and Lu, Y. (2003). “Assessment of highway bridge upgrading by dynamic testing and finite element model updating.” J. Bridge Eng., 162–172.
Cawley, P., and Alleyne, D. (1996). “The use of lamb waves for the long range inspection of large structures.” Ultrasonics, 34(2–5), 287–290.
Chang, P. C., Flatau, A., and Liu, S. C. (2003). “Review paper: Health monitoring of civil infrastructure.” Struct. Health Monit., 2(3), 257–267.
Chen, Y., Feng, M. Q., and Tan, C.-A. (2009). “Bridge structural condition assessment based on vibration and traffic monitoring.” J. Eng. Mech., 747–758.
Cho, H.-N., Lim, J.-K., and Choi, H.-H. (2001). “Reliability-based fatigue failure analysis for causes assessment of a collapsed steel truss bridge.” Eng. Fail. Anal., 8(4), 311–324.
Cho, Y. (2000). “Estimation of ultrasonic guided wave mode conversion in a plate with thickness variation.” IEEE T. Ultrason. Ferr., 47(3), 591–603.
Dalton, R. P., Cawley, P., and Lowe, M. J. S. (2001). “The potential of guided waves for monitoring large areas of metallic aircraft fuselage structure.” J. Nondestruct. Eval., 20(1), 29–46.
Deng, L., and Cai, C. S. (2009). “Identification of parameters of vehicles moving on bridge.” Eng. Struct., 31(10), 2474–2485.
Di Scalea, F. L., and Salamone, S. (2008). “Temperature effects in ultrasonic lamb wave structural health monitoring systems.” J. Acoust. Soc. Am., 124(1), 161–174.
Eckstein, B., Fritzen, C.-P., and Bach, M. (2008). “Advancements in self-diagnosis of bonded piezoelectric transducers.” Proc., 4th European Workshop on Structural Health Monitoring, DEStech Publications, Lancaster, PA, 425–432.
Fromme, P., Wilcox, P. D., Lowe, M. J. S., and Cawley, P. (2006). “On the development and testing of a guided ultrasonic wave array for structural integrity monitoring.” IEEE T. Ultrason. Ferr., 53(4), 777–784.
Giurgiutiu, V. (2008). Structural health monitoring with piezoelectric wafer active sensors, Elsevier, London.
Greve, D. W., Neumann, J. J., Nieuwenhuis, J. H., Oppenheim, I. J., and Tyson, N. L. (2005). “Use of lamb waves to monitor plates: Experiments and simulations.” Proc., SPIE 5765, Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems, 281.
Hao, S. (2010). “I-35W bridge collapse.” J. Bridge Eng., 608–614.
Huth, O., Feltrin, G., Maeck, J., Kilic, N., and Motavalli, M. (2005). “Damage identification using modal data: Experiences on a prestressed concrete bridge.” J. Struct. Eng., 1898–1910.
Jaishi, B., and Ren, W.-X. (2005). “Structural finite element model updating using ambient vibration test results.” J. Struct. Eng., 617–628.
Kim, S. B., and Sohn, H. (2007). “Instantaneous reference-free crack detection based on polarization characteristics of piezoelectric materials.” Smart Mater. Struct., 16(6), 2375–2387.
Kim, S. D., In, C. W., Cronin, K. E., Sohn, H., and Harries, K. (2007). “Reference-free NDT technique for debonding detection in CFRP-strengthened RC structures.” J. Struct. Eng., 1080–1091.
Lee, J. J., Fukuda, Y., Shinozuka, M., Cho, S., and Yun, C. (2007). “Development and application of a vision-based displacement measurement system for structural health monitoring of civil structures.” Smart Struct. Syst., 3(3), 373–384.
Lee, J.-J., Lee, J. W., Yi, J. H., Yun, C.-B., and Jung, H. Y. (2005). “Neural networks-based damage detection for bridges considering errors in baseline finite element models.” J. Sound Vib., 280(3–5), 555–578.
Lee, J. W., Kim, J. D., Yun, C.-B., Yi, J. H., and Shim, J. M. (2002). “Health monitoring method for bridges under ordinary traffic loadings.” J. Sound Vib., 257(2), 247–264.
Lee, S. J., Sohn, H., and Hong, J. W. (2010). “Time reversal-based piezoelectric transducer self-diagnosis under varying temperature.” J. Nondestruct. Eval., 29(2), 75–91.
Lichtenstein, A. G. (1993). “The silver bridge collapse recounted.” J. Perform. Constr. Fac., 249–261.
Lin, X. K., Zhang, L. M., Guo, Q. T., and Zhang, Y. F. (2009). “Dynamic finite element model updating of prestressed concrete continuous box-girder bridge.” Earthq. Eng. Vib., 8(3), 399–407.
Lynch, J. P. (2007). “An overview of wireless structural health monitoring for civil structures.” Philos. Trans. R. Soc. A., 365(1851), 345–372.
Maeck, J., Peeters, B., and De Roeck, G. (2001). “Damage identification on the Z24 bridge using vibration monitoring analysis.” Smart Mater. Struct., 10(3), 512–517.
Moyo, P., Brownjohn, J. M. W., and Omenzetter, P. (2004). “Highway bridge live loading assessment and load carrying capacity estimation using a health monitoring system.” Struct. Eng. Mech., 18(5), 609–626.
Overly, T., Park, G., Farinholt, H., and Farrar, C. (2009). “Piezoelectric active-sensor diagnostics and validation using instantaneous baseline data.” IEEE Sens. J., 9(11), 1414–1421.
Park, G., Cudney, H., and Inman, D. J. (2000). “Impedance-based health monitoring of civil structural components.” J. Infrastruct. Syst., 153–160.
Park, G., Farrar, C. R., Di Scalea, F. L., and Coccia, S. (2006). “Self-diagnosis and validation of active sensors used for structural health monitoring.” Proc., SPIE, Vol. 6173, Smart Structures and Materials 2006: Smart Structures and Integrated Systems, 61731N.
Park, S., Lee, C. G., and Sohn, H. (2010). “Reference-free crack detection using transfer impedance.” J. Sound Vib., 329(12), 2337–2348.
Pfeil, M. S., Battista, R. C., and Mergulhao, A. J. R. (2005). “Stress concentration in steel bridge orthotropic decks.” J. Constr. Steel Res., 61(8), 1172–1184.
Qiang, W., and Shenfang, Y. (2009). “Baseline-free imaging method based on new PZT sensor arrangements.” J. Intel. Mat. Syst. Struct., 20(14), 1663–1673.
Raghavan, A., and Cesnik, C. E. S. (2007). “Review of guided-wave structural health monitoring.” Shock. Vib. Dig., 39(2), 91–114.
Raghavan, A., and Cesnik, C. E. S. (2008). “Effects of elevated temperature on guided-wave structural health monitoring.” J. Intel. Mat. Syst. Struct., 19(12), 1383–1398.
Rose, J. (2002). “A baseline and vision of ultrasonic guided wave inspection potential.” J. Press. Vess. Technol., 124(3), 273–282.
Soh, C. K., Tseng, K., Bhalla, S., and Gupta, A. (2000). “Performance of smart piezoceramic patches in health monitoring of a RC bridge.” Smart Mater. Struct., 9(4), 533–542.
Sohn, H. (2007). “Effects of environmental and operational variability on structural health monitoring.” Philos. Trans. R. Soc. A, 365(1851), 539–560.
Sohn, H., et al. (1999). “An experimental study of temperature effects on modal parameters of the Alamosa Canyon Bridge.” Earthq. Eng. Struct. D., 28(8), 879–897.
Sohn, H., and Kim, S. B. (2010). “Development of dual PZT transducers for instantaneous crack detection in thin plate structures.” IEEE T. Ultrason. Ferr., 57(1), 229–240.
Sohn, H., Park, H. W., Law, K. H., and Farrar, C. R. (2007). “Combination of a time reversal process and a consecutive outlier analysis for baseline-free damage diagnosis.” J. Intel. Mat. Syst. Struct., 18(4), 335–346.
Soyoz, S., and Feng, M. Q. (2009). “Long-term monitoring and identification of bridge structural parameters.” Comput. Aided Civ. Infrastruct. Eng., 24(2), 82–92.
Swartz, R. A., Zimmerman, A., and Lynch, J. P. (2007). “Structural health monitoring system with the latest information technologies.” Proc., 5th Infrastruct. and Environ. Manage. Symp., Yamaguchi, Japan.
Viktorov, I. A. (1967). Rayleigh and lamb waves: Physical theory and applications, Plenum, NY.
Yi, J.-H., et al. (2007). “Structural performance evaluation of a steel-plate girder bridge using ambient acceleration measurements.” Smart Struct. Syst., 3(3), 281–298.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: Apr 16, 2011
Accepted: Apr 8, 2013
Published online: Apr 10, 2013
Published in print: Mar 1, 2014
Discussion open until: Apr 6, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.