Hydraulic structure undermining attributable to scour can cause structural damage or collapse. Experiments were performed in a laboratory channel on scour downstream of a stilling basin of a low-head spillway to ascertain the feasibility of air injection for scour reduction, an idea that has not been previously attempted. Various hydraulic flow conditions without air injection indicate that the condition of stilling basin water elevation lower than the spillway crest, under high headwater-to-tailwater depth ratio, results in the deepest scour. Over 120 experiments were performed to determine the optimal parameters for scour reduction by air injection. It was found that optimal scour-reducing conditions consist of (1) air injection at an air-to-water velocity ratio of 251, (2) vertical air injection at the same elevation as the stilling basin exit point, (3) using diffuser hole diameters corresponding to a ratio of air-to-water velocity equal to 251 spanning the entire width of the stilling basin, and (4) a diffuser hole spacing 0.04 times the diffuser width. Scour can thus be reduced by approximately 59% near the structure. Air compressors and diffuser pipe diameter and hole sizes corresponding to these conditions would be required in prototype installations.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This study was partially funded by the South Florida Water Management District. The opinion expressed or statements made herein are solely those of the authors and do not reflect the views of the agencies of the authors’ affiliations.
References
Afify, A. M., and Urroz, G. E. (1993). “Plunge-pool aeration due to inclined jets.” Proc., Hydraulic Conf., ASCE, Reston, VA, 851–855.
Afify, A. M., and Urroz, G. E. (1994). “Plunge-pool scour by inclined jets.” Proc., Hydraulic Engineering 1994 Conf., ASCE, Reston, VA, 1040–1044.
Bennett, S. J., Alonso, C. V., Prasad, S. N., and Romkens, M. J. M. (2000). “Experiments on headcut growth and migration in concentrated flows typical of upland areas.” Water Resour. Res., 36(7), 1911–1922.
Blanckaert, K., Buschman, F. A., Schielen, R., and Wijbenga, J. H. A. (2008). “Redistribution of velocity and bed-shear stress in straight and curved open channels by means of a bubble screen: Laboratory experiments.” J. Hydraul. Eng., 184–195.
Brevik, I. (1977). “Two-dimensional air-bubble plume.” J. Waterways Harbors Coastal Eng. Div., 103(1), 101–115.
Brevik, I., and Killie, R. (1996). “Phenomenological description of the axisymmetric air-bubble plume.” Int. J. Multiphase Flow, 22(3), 535–549.
Brevik, I., and Kristiansen, O. (2002). “The flow in and around air-bubble plumes.” Int. J. Multiphase Flow, 28(4), 617–634.
Campbell, F. B., and Guyton, B. (1953). “Air demand in gated outlet works.” Proc., Minnesota Int. Hydraulics Conversion, ASCE, Reston, VA539–533.
Canepa, S., and Hager, W. H. (2003). “Effect of jet air content on plunge pool scour.” J. Hydraul. Eng., 358–365.
Champagne, T. M. (2011) “Physical modeling of air injection as a scour remediation technique near gated weir stilling basins.” M.S. thesis, Michigan Technology Univ., Houghton, MI.
Champagne, T. M., Barkdoll, B. D., Gonzalez-Castro, J. A., and Deaton, L. (2010). “Experiments identifying worst case scour conditions of gated weir stilling basins.” Proc., World Environmental and Water Resources Congress 2010, ASCE, Reston, VA, 1905–1914.
Cheng, N. S., and Chiew, T. M. (1999) “Incipient sediment motion with seepage.” J. Hydraul. Res., 37(5), 665–681.
D’Agostino, V., and Ferro, V. (2004). “Scour on alluvial bed downstream of grade-control structures.” J. Hydraul. Eng., 24–37.
Dey, S., and Sarkar, A. (2006). “Scour downstream of an apron due to submerged horizontal jets.” J. Hydraul. Eng., 246–257.
Dey, S., and Sarkar, A. (2007). “Effect of upward seepage on scour and flow downstream of an apron due to submerged jets.” J. Hydraul. Eng., 59–69.
Dey, S., and Westrich, B. (2003). “Hydraulics of submerged jet subject to change in cohesive bed geometry.” J. Hydraul. Eng., 44–53.
Ervine, D. A. (1976). “Entrainment of air in water.” Int. Water Power Dam Constr., 28(12), 27–30.
Ervine, D. A., McKeogh, E., and Elsawy, E. M. (1980). “Effect of turbulence intensity on the rate of air entrainment by plunging water jets.” Proc., Inst. Civil Eng. (London) Part 1, 69(pt 2), 425–445.
Freire, A. P. S., Miranda, D. D. E., Luz, L. M. S., and Franca, G. F. M. (2002). “Bubble plumes and the Coanda effect.” Int. J. Multiphase Flow, 28(8), 1293–1310.
Gabillet, C., Colin, C., and Fabre, J. (2002). “Experimental study of bubble injection in a turbulent boundary layer.” Int. J. Multiphase Flow, 28(4), 553–578.
Guan, D., Melville, B., and Friedrich, H. (2014). “Flow patterns and turbulence structures in a scour hole downstream of a submerged weir.” J. Hydraul. Eng., 68–76.
Guan, D., Melville, B., and Friedrich, H. (2015). “Live-bed scour at submerged weirs.” J. Hydraul. Eng., 04014071.
Hadjerioua, B., Rizk, T. A., Laursen, E. M., and Petersen, M. S. (1994). “Measuring air concentration in flowing air-water mixtures.” Proc., Symp. of Fundamentals and Advancements in Hydraulic Measurements and Experimentation, ASCE, Reston, VA, 289–295.
Hager, W. H. (1998). “Plunge pool scour: Early history and hydraulicians.” J. Hydraul. Eng., 1185–1187.
Hamid, A. J., Farrant, R. F. T., and Ahmad, M. (1952). “Air entraining devices and their use in correcting flow conditions at weirs and canal outfalls.” Proc., Minnesota Int. Hydraulics Conversion, ASCE, Reston, VA, 519–527.
Henderson, F. M. (1966). Open channel flow, MacMillan, New York.
Jia, Y., Kitamura, T., and Wang, S. S. Y. (2001). “Simulation of scour process in plunging pool of loose bed-material.” J. Hydraul. Eng., 219–229.
Johnson, G. (1967). “Effect of entrained air on the scouring capacity of water jets.” Proc., 12th IAHR Congress, International Association for Hydro-Environment Engineering and Research, Madrid, Spain, 218–226.
Liu, P. (2005). “A new method for calculating depth of scour pit caused by overflow water jets.” J. Hydraul. Res., 43(6), 696–702.
Machina, D. W., and Bewtra, J. K. (1985). “Design factors for the scouring of deposited materials in water and wastewater treatment systems.” Can. J. Civ. Eng., 12(3), 567–572.
Martinez-Bazan, C., Montaes, J. L., and Lasheras, J. C. (2002). “Statistical description of the bubble cloud resulting from the injection of air into a turbulent water jet.” Int. J. Multiphase Flow, 28(4), 597–615.
Martins, R. B. F. (1975). “Scouring of rocky riverbeds by free-jet spillways.” Water power and dam construction, IPC Electrical-Electronic Press, London, 152–153.
Mason, P. J. (1989). “Effects of air entrainment on plunge pool scour.” J. Hydraul. Eng., 385–399.
Mason, P. J., and Arumugam, K. (1985). “Free jet scour below dams and flip buckets.” J. Hydraul. Eng., 220–235.
McKeogh, E. J., and Elsawy, E. M. (1980). “Air entrained in pool by plunging water jet.” J. Hydraul. Div., 106(10), 1577–1593.
Melville, B., and Chiew, Y. (1999). “Time scale for local scour at bridge piers.” J. Hydraul. Eng., 59–65.
Melville, B., and Lim, S. (2014). “Scour caused by 2D horizontal jets.” J. Hydraul. Eng., 149–155.
Melville, B. W., Odgaard, A. J., Wang, Y., and Sinha, S. K. (1992). “Hydraulic model study of sediment management alternatives commonwealth Edison Byron Station river water intake structure.”, Univ. of Iowa, Iowa City, IA.
Nakato, T. (1990). “A hydraulic model study of the proposed pump-intake and discharge flume: Florida Power Corporation’s Crystal River helper cooling-tower project.”, Univ. of Iowa, Iowa City, IA.
Neto, I. E. L., Zhu, D. Z., and Rajaratnam, N. (2008). “Air injection in water with different nozzles.” J. Environ. Eng., 283–294.
Odgaard, A. J., Wang, Y., and Neary, V. S. (1990). “Hydraulic-laboratory model study of river intake at Duane Arnold energy center.”, Univ. of Iowa, Iowa City, IA.
Pagliara, S., Hager, W. H., and Minor, H. E. (2006). “Hydraulics of plane plunge pool scour.” J. Hydraul. Eng., 450–461.
Peterka, A. J. (1953). “The effect of entrained air on cavitation pitting.” Proc., Minnesota Int. Hydraulic Conversion, ASCE, Reston, VA, 507–518.
Qi, M., Chiew, Y. M., and Hong, J. (2013). “Suction effects on bridge pier scour under clear-water conditions.” J. Hydraul. Eng., 621–629.
Radice, A., and Davari, V. (2014). “Roughening elements as abutment scour countermeasures.” J. Hydraul. Eng., 06014014.
Rajaratnam, N., and Mazurek, K. A. (2002). “Erosion of a polystyrene bed by obliquely impinging circular turbulent air jets.” J. Hydraul. Res., 40(6), 709–716.
Rehmeyer, W. (1990). “The effect of aeration on scour.” Proc., National Hydraulic Conf., ASCE, Reston, VA, 531–536.
Schmocker, L., Pfister, M., Hager, W. H., and Minor, H. E. (2008). “Aeration characteristics of ski jump jets.” J. Hydraul. Eng., 90–97.
Simiano, M., Zboray, R., de Cachard, F., Lakehal, D., and Yadigaroglu, G. (2006). “Comprehensive experimental investigation of the hydrodynamics of large-scale, 3D, oscillating bubble plumes.” Int. J. Multiphase Flow, 32(10–11), 1160–1181.
Stein, O. R., Alonso, C. V., and Julien, P. Y. (1993). “Mechanics of jet scour downstream of a headcut.” J. Hydraul. Res., 31(6), 723–738.
Tafarojnoruz, A., Gaudio, R., and Calomino, F. (2012). “Bridge pier scour mitigation under steady and unsteady flow conditions.” Acta Geophys., 60(4), 1076–1097.
Van Hout, R., Gulitski, A., Barnea, D., and Shemer, L. (2002). “Experimental investigation of the velocity field induced by a Taylor bubble rising in stagnant water.” Int. J. Multiphase Flow, 28(4), 579–596.
Xu, W., Deng, J., Qu, J., Liu, S., and Wang, W. (2004). “Experimental investigation on influence of aeration on plane jet scour.” J. Hydraul. Eng., 160–164.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Sep 14, 2015
Accepted: Jun 30, 2016
Published online: Aug 26, 2016
Published in print: Dec 1, 2016
Discussion open until: Jan 26, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.