Penetration Behavior and Sample Quality of Hydraulically Activated Fixed-Piston Samplers
Publication: Journal of Geotechnical and Geoenvironmental Engineering
Volume 143, Issue 3
Abstract
This study presents an enhanced hydraulic fixed-piston (HNS-N) sampler that reflects a local practice. This sampler was employed at a deltaic site along with two other types of samplers: a similar hydraulic (HNS-K) type with no vacuum breaker and an oil-operated (ONS) sampler that is equipped with a vacuum breaker and is fixed at the center of a casing. The generation of a slowly but erratically increasing pressure in the hydraulic samplers often does not ensure constant speed and full penetration; thus, the pressure in these samplers was increased rapidly after the drill rods were filled with water. By contrast, the pressure in the ONS sampler was increased instantaneously. The hydraulic samplers exhibited slightly discrete penetration behavior, whereas the ONS sampler induced constant penetration. The sample qualities of the samplers are ordered based on an evaluation via two nondestructive methods and a consolidation test, as follows: . The sample quality was affected significantly by the uniformity of penetration behavior and slightly by the penetration rate (mostly ). In addition, sample quality was strongly influenced by the use of the vacuum breaker.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This work was supported by the Korea Science and Engineering Foundation (KOSEF) Research Program grant funded by the Korean government (MEST) (No. 2016R1A2A2A05005131) and by the graduate students at Dong-A University, Busan, Korea.
References
ASTM. (2007a). “Standard practice for sampling of soil using the hydraulically operated stationary piston sampler.” ASTM D6519-05, West Conshohocken, PA.
ASTM. (2007b). “Standard test method for one-dimensional consolidation properties of soils using incremental loading.” ASTM D2435-04, West Conshohocken, PA.
ASTM. (2008). “Standard test method for one-dimensional consolidation properties of soils using controlled-strain loading.” ASTM D4186-06, West Conshohocken, PA.
Chung, S. G., Giao, P. H., Kim, G. J., and Leroueil, S. (2002a). “Geotechnical characteristics of Pusan clays.” Can. Geotech. J., 39(5), 1050–1060.
Chung, S. G., Giao, P. H., and Tanaka, H. (2002b). “Geotechnical characteristics and engineering problems of Pusan clays.” Int. Workshop on Characterisation and Engineering Properties of Natural Soils, Vol. 1, A.A. Balkema, Rotterdam, Netherlands, 505–541.
Chung, S. G., Kwag, J. M., Giao, P. H., Back, S. H., and Prasad, K. N. (2004). “A study of soil disturbance of Pusan clays with reference to drilling, sampling and extruding.” Géotechnique, 54(1), 61-65.
Chung, S. G., and Kweon, H. J. (2013). “Oil-operated fixed-piston sampler and its applicability.” J. Geotech. Geoenviron. Eng., 134–142.
Chung, S. G., Lee, J. M., and Jang, W. Y. (2014). “Comparing the quality of samples obtained by three types of fixed piston samplers for soft sensitive clay.” Eng. Geol., 179, 50–58.
Chung, S. G., Ryu, C. K., Min, S. C., Lee, J. M., Hong, Y. P., and Odgerel, E. (2012). “Geotechnical characterization of Busan clay.” KSCE J. Civ. Eng., 16(3), 341–350.
Clayton, C. R. I., Matthews, M. C., and Simons, N. E. (2002). Site investigation, 2nd Ed., Blackie, London.
Donohue, S., and Long, M. (2010). “Assessment of sample quality in soft clay using shear wave velocity and suction measurements.” Géotechnique, 60(11), 883–889.
GUS Sampler. (2016). “Bulletin of GUS sampler.” 〈http://www.ackerdrill.com/gus-sampler.phpf〉 (Apr. 17, 2016).
Hight, D. W. (2001). “Sampling effects in soft clay: An update on Ladd and Lambe (1963).” Proc., Symp., Soil Behavior and Soft Ground Construction, ASCE, Cambridge, MA, 86–121.
Horng, V., Tanaka, H., and Obara, T. (2010). “Effects of sampling tube geometry on soft clayey sample quality evaluated by nondestructive methods.” Soils Found., 50(1), 93–107.
Hvorslev, M. J. (1949). “Subsurface exploration and sampling of soils for civil engineering purposes.” Waterways Experimental Station, Vicksburg, MS.
Japanese Geotechnical Society. (1998). “Method for obtaining undisturbed soil samples using thin-walled tube sampler with fixed piston.”, Tokyo.
Kawaguchi, T., Mitachi, T., and Shibuya, S. (2001). “Evaluation of shear wave travel time in laboratory bender element test.” Proc., 15th ICSMGE, Vol. 1, Balkema, Rotterdam, Netherlands, 155–158.
Ladd, C. C., and Lambe, T. W. (1963). “The strength of undisturbed clay determined from undrained tests.” Symp. on Laboratory Shear Testing of Soils, ASTM, Baltimore, 342–371.
Landon, M. M., DeGroot, D. J., and Sheahan, T. C. (2007). “Nondestructive sample quality assessment of a soft clay using shear wave velocity.” J. Geotech. Geoenviron. Eng., 424–432.
Lee, J. M., Chung, S. G., Kweon, H. J., and Singh, V. K. (2016). “Effect of fixed-piston sampler on sensitive clayey sample quality.” Geotechnical Engineering, Proc., ICE, ICE (Institution of Civil Engineers), London.
Lee, J. S., and Santamarina, J. C. (2005). “Bender elements: Performance and signal interpretation.” J. Geotech. Geoenviron. Eng., 1063–1070.
Long, M., Hadj, N. E., and Hagberg, K. (2009). “Quality of conventional fixed piston samples of Norwegian soft clay.” J. Geotech. Geoenviron. Eng., 185–198.
Lunne, T., Berre, T., Andersen, K. H., Strandvik, S., and Sjursen, M. (2006). “Effects of sample disturbance and consolidation procedures on measured shear strength of soft marine Norwegian clays.” Canadian Geotech. J., 43(7), 726–750.
Marchetti, S., Monaco, P., Totani, G., and Marchetti, D. (2008). “In situ tests by seismic dilatometer (SDMT).” From research to practice in geotechnical engineering, Laier J. E., Crapps D. K., and Hussein M. H., eds., ASCE, Reston, VA, 292–311.
Osterberg, J. O. (1952). “New piston type soil sampler.” Eng. News Record, 148(17), 77–78.
Osterberg, J. O. (1973). “An improved hydraulic piston sampler.” Proc., 8th Int. Conf. on Soil Mechanics and Foundation Engineering, Vol. 1, U.S.S.R. National Society for Soil Mechanics and Foundation Engineering, Moscow, 317–321.
Ozer, A. T., Lawton, E. C., and Bartlett, S. (2012). “New method to determine proper strain rate for constant rate-of-strain consolidation tests.” Can. Geotech. J., 49(1), 18–26.
Poirier, S. E., DeGroot, D. J., and Sheahan, T. C. (2005). “Measurement of suction in marine clay as an indicator of sample disturbance.” Proc., GeoFrontiers 2005 Congress, Site Characterisation and Modelling, ASCE Geo-Institute, Austin, TX.
Singh, V. K., and Chung, S. G. (2015). “Evaluation of overconsolidation ratios from laboratory and in situ tests on Busan clay.” Eng. Geol., 199, 38–47.
Tanaka, H., and Tanaka, M. (2006). “Main factors governing residual effective stress for cohesive soils sampled by tube sampling.” Soils Found., 46(2), 209–219.
U.S. Army Corps of Engineers. (2001). “Engineering and design: Soil sampling.”, Washington, DC.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Oct 2, 2015
Accepted: Jul 7, 2016
Published online: Sep 9, 2016
Discussion open until: Feb 9, 2017
Published in print: Mar 1, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.