Uplift Performance of Anchor Plates Embedded in Cement-Stabilized Backfill
Publication: Journal of Geotechnical and Geoenvironmental Engineering
Volume 139, Issue 3
Abstract
A series of pullout tests is presented in this paper and is used to identify the kinematics of failure and the uplift response of circular anchor plates embedded in sand-cement stabilized layers at distinct normalized embedment depths (), where is the thickness of the treated layer and is the diameter of the anchor plates. Experimental results show that the uplift capacity of anchor plates embedded in sand backfill layers increases considerably after mixing 3% cement with the backfill material. Distinct failure mechanisms observed for anchor plates embedded in both sand and cement-stabilized backfills are shown to be a function of . The addition of cement to the sand backfill leads to an increase in uplift capacity of 9 times for an ratio of 1.0 and of 13 times for an ratio of 2.0. For sand backfill with , the failure surface had a truncated cone shape with a vertical inclination of 22°, whereas for of 1.5 and 2.0, radial cracking was observed, and final failure surfaces had inclinations of 26 and 30°, respectively. Pullout of anchor plates in cement-stabilized backfills at ratios ranging from 1.0 to 2.0 exhibit two distinct characteristics: (a) a linear elastic deformation response at small pullout displacements and (b) a later stage where radial fracturing of the stabilized backfill leads to hardening just prior to failure. Radial cracks starting at the top of the layer near the center of the anchor plates start to propagate only at about 90% of the final uplift failure load, irrespective of .
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The authors wish to express their gratitude to the Brazilian Oil Company (Petrobras) for the financial support of the research group.
References
Associação Brasileira de Normas Técnicas. (1991). “Foundations: Static loading tests.” ABNT NBR-12131, Rio de Janeiro, Brazil (in Portuguese).
ASTM. (1998). “Standard test method for bearing capacity of soil for static load and spread footings.” ASTM D1194, Philadelphia.
ASTM. (2006). “Standard test method for unconfined compressive strength of cohesive soil.” ASTM D2166, Philadelphia.
Balla, A. (1961). “The resistance to breaking out mushroom foundations for pylons.” Proc., 5th Int. Conf. on Soil Mechanics and Foundation Engineering, Vol. 1, Paris, 569–576.
Berardi, R., and Lancellotta, R. (1991). “Stiffness of granular soil from field performance.” Geotechnique, 41(1), 149–157.
Biarez, J., and Barraud, Y. (1968). “Adaptation des foundations de pylons au terrain par les methods de la méchanique des sols.” Rapport 22-06, Conseil International des Grands Réseaux Électriques, Paris (in French).
Consoli, N. C., Cruz, R. C., Floss, M. F., and Festugato, L. (2010). “Parameters controlling tensile and compressive strength of artificially cemented sand.” J. Geotech. Geoenviron. Eng., 136(5), 759–763.
Consoli, N. C., Dalla Rosa, F., and Fonini, A. (2009a). “Plate load tests on cemented soil layers overlaying weaker soil.” J. Geotech. Geoenviron. Eng., 135(12), 1846–1856.
Consoli, N. C., Vendruscolo, M. A., and Prietto, P. D. M. (2003). “Behavior of plate load tests on soil layers improved with cement and fiber.” J. Geotech. Geoenviron. Eng., 129(1), 96–101.
Consoli, N. C., Viana da Fonseca, A., Cruz, R. C., and Heineck, K. S. (2009b). “Fundamental parameters for the stiffness and strength control of artificially cemented sand.” J. Geotech. Geoenviron. Eng., 135(9), 1347–1353.
Lehane, B. M., Gaudin, C., Richards, D. J., and Rattley, M. J. (2008). “Rate effects on the vertical uplift capacity of footings founded in clay.” Geotechnique, 58(1), 13–21.
Meyerhof, G. G., and Adams, J. I. (1968). “The ultimate uplift capacity of foundations.” Can. Geotech. J., 5(4), 225–244.
Murray, E. J., and Geddes, J. D. (1987). “Uplift of anchor plates in sand.” J. Geotech. Engrg., 113(3), 202–215.
Pacheco, M. P., Danziger, F. A. B., and Pereira Pinto, C. (2008). “Design of shallow foundations under tensile loading for transmission line towers: An overview.” Eng. Geol., 101(3-4), 226–235.
Rattley, M. J., Lehane, B. M., Consoli, N. C., and Richards, D. J. (2008). “Uplift of shallow foundations with cement-stabilised backfill.” Ground Improv., 161(2), 103–110.
Rowe, R. K., and Davis, E. H. (1982a). “The behavior of anchor plates in clay.” Geotechnique, 32(1), 9–23.
Rowe, R. K., and Davis, E. H. (1982b). “The behavior of anchor plates in sand.” Geotechnique, 32(1), 25–41.
Stefanoff, G., Jellev, J., Tsankova, N., Karachorov, P., and Slavov, P. (1983). “Stress and strain state of a cement-loess cushion.” Proc., 8th European Conf. of Soil Mechanics and Foundation Engineering, A. A. Balkema, Rotterdam, Netherlands, 811–816.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: Jan 10, 2011
Accepted: May 30, 2012
Published online: Feb 15, 2013
Published in print: Mar 1, 2013
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.