Full-Scale Testing of Open-Ended Steel Pipe Piles in Thick Varved Clayey Silt Deposits along the Delaware River in New Jersey
Publication: Journal of Geotechnical and Geoenvironmental Engineering
Volume 139, Issue 3
Abstract
Although many studies have been done to investigate the axial behaviors of open-ended piles in sands, few studies have been reported for weak clayey silts. To develop reliable models for the design of open-ended steel-pipe piles driven into 29-m-thick varved clayey silt deposits, a series of full-scale field load tests including large-strain dynamic tests and static cyclic axial-compression-load tests was conducted on two groups of instrumented piles. Through analysis of the test data, soil parameters were back-calculated for estimation of pile capacities using the static-bearing-capacity formulas and cone-resistance-based methods. The comparisons between the calculated results and the field load test data demonstrated that the following considerations can be adopted in the design of static compression capacities of an open-ended pipe pile penetrating through thick varved clayey silts to end-bearing in dense cohesionless soils: (1) a fully plugged condition can be assumed, (2) cone resistance with an upper limit of 4,788 kPa (100 ksf) can be used for unit base resistance on the soil plug, and (3) exterior unit shaft resistance can be estimated using two-thirds of the total unit shaft resistance.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
Many organizations and people contributed to the success of this research project, and special thanks are due to Mr. Junius Allen of BP and the former Geotechnical Engineers of WPC, Inc., i.e., Mr. Wu Yang, Mr. Joshua Adams, Mr. Jian Fang, Mr. Donovan Ledford, and Dr. Ed Hajduk. The financial support offered by NSFC Grant No. 51109125, the Fundamental Research Funds for the Central Univs. No. 0230219134, Innovation Program of Shanghai Municipal Education Commission No.13ZZ027, and the project sponsored by SRF for ROCS, SEM are gratefully acknowledged. Dr. Ye Lu from Shanghai Univ. is appreciated for her contribution to improving the quality of this paper. Finally, the insightful comments and suggestions from the three anonymous reviewers, the Associate Editor, and the Editor are sincerely appreciated.
References
Almeida, M. S. S., Danziger, F. A. B., and Lunne, T. (1996). “The use of piezocone test to predict axial capacity of driven and jacked piles.” Can. Geotech. J., 33(1), 23–41.
American Petroleum Institute, API (1993). “Recommended practice for planning, designing and constructing fixed offshore platforms: Load and resistance factor design.” API 2A-LRFD, Washington, DC.
ASTM. (1994). “Standard test method for piles under static axial compressive load.” D1143, West Conshohocken, PA.
Bozozuk, M., Keenan, G. H., and Pheeney, P. E. (1979). “Analysis of load tests on instrumented steel test piles in compressible silty soils.” ASTM Spec. Tech. Publ., 670, 153–180.
Bustamante, M., and Gianeselli, L. (1982). “Pile bearing capacity prediction by means of static penetrometer CPT.” Proc., 2nd European Symp. on Penetration Testing, Vol. 2, ESOPT-II, A.A. Balkema, Rotterdam, Netherlands, 493–500.
Davisson, M. T. (1972). “High capacity piles.” Proc., Lecture Series on Innovations in Foundation Construction, ASCE, Reston, VA, 81–112.
De Kuiter, J., and Beringen, F. L. (1979). “Pile foundations for large North Sea structures.” Mar. Georesour. Geotechnol., 3(3), 267–314.
Eslami, A., and Fellenius, B. H. (1997). “Pile capacity by direct CPT and CPTu methods applied to 102 case histories.” Can. Geotech. J., 34(6), 886–904.
Hannigan, P. J., Goble, G. G., Thendean, G., Likins, G. E., and Rausche, F. (1997). “Design and construction of driven pile foundations.” FHWA-HA-97-013, U.S. Dept. of Transportation, Washington, DC.
Hoit, M., Akher, A. A., and Townsend, F. (2002). Documentation of computer program FB-Deep version 1.21, Florida Bridge Software Institute, Univ. of Florida, Gainesville, FL.
Kyfor, Z. G., Schonore, A. S., Cario, T. A., and Bailey, P. F. (1991). “Static testing of deep foundations.” FHWA-SA-91-042, U.S. Dept. of Transportation, Washington, DC.
Mathias, D., and Cribbs, M. (1998). DRIVEN 1.2: A Microsoft Windows based program for determining ultimate vertical static pile capacity, User’s manual. FHWA-SA-98-074, U.S. Department of Transportation, Federal Highway Administration (FHwA), Washington, DC.
McVay, M. C., Bardri, D., and Hu, Z. (2004). “Determination of axial pile capacity of prestressed concrete cylinder piles.” Rep. No. 4910-4504-877-12, Florida Department of Transportation (FDOT), Tallahassee, FL.
O’Neill, M. W., and Raines, R. D. (1991). “Load transfer for pipe piles in highly pressured dense sand.” J. Geotech. Eng., 117(8), 1208–1226.
Paik, K. H., and Salgado, R. (2003). “Determination of the bearing capacity of open-ended piles in sand.” J. Geotech. Geoenviron. Eng., 129(1), 46–57.
Paik, K., Salgado, R., Lee, J., and Kim, B. (2003). “Behavior of open- and closed-ended piles driven into sands.” J. Geotech. Geoenviron. Eng., 129(4), 296–306.
Paikowsky, S. G., Operstein, V., and Bachand, M. L., Jr. (1999). “Express method of pile testing by static cyclic loading.” Rep. No. MHD-GERL-99-04, Massachusetts Highway Dept., Boston.
Paikowsky, S. G., and Whitman, R. V. (1990). “The effect of plugging on pile performance and design.” Can. Geotech. J., 27(4), 429–440.
Raines, R. D., Ugaz, O., and O’Neill, M. (1992). “Driving characteristics of open toe piles in sand.” J. Geotech. Eng., 118(1), 72–88.
Tomlinson, M. J. (1994). Pile design and construction practice, 4th Ed., E&FN Spon, London, 411.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: Aug 19, 2011
Accepted: May 14, 2012
Published online: May 17, 2012
Published in print: Mar 1, 2013
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.