Abstract
This study proposes a vibration control system consisting of a swing story subsystem, a lateral force resisting subsystem, and connecting dampers. The swing story subsystem comprising hinged columns connected to continuous beams is employed to resist the gravity load, and perimeter moment-resisting frames the lateral force. Dampers are adopted to transfer lateral forces between the two subsystems and are used to dissipate seismic energy. The main characteristic of the system is that both the fundamental and higher-mode responses can be reduced remarkably compared with conventional moment-resisting frame structures. This paper establishes equations of motion of the proposed swing story control system, and the dampers are optimally designed by a multiobjective optimization algorithm with the combination of the stability maximization and criteria. To avoid instability of the flexible swing stories, sufficient stiffness is required for the dampers, and buckling analysis is thus conducted to determine the required minimum stiffness. Excellent vibration control effects of the proposed system are verified through numerical analyses of three-story and nine-story benchmark structures.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The study is supported by National Nature Science Foundation of China (51608391 and 51508401), which is greatly appreciated.
References
ABAQUS [Computer software]. Dassault Systèmes, Waltham, MA.
ASCE. (2010). “Minimum design loads for buildings and other structures.” ASCE/SEI7-10, Reston, VA.
Building Center of Japan. (1997). “BCJ Seismic provisions for design of building structures.” Tokyo (in Japanese).
Casciati, S., and Faravelli, L. (2014). “Quantity vs. quality in the model order reduction (MOR) of a linear system.” Smart Struct. Syst., 13(1), 99–109.
Chancellor, N. B., Eatherton, M. R., Roke, D. A., and Akbas, T. (2014). “Self-centering seismic lateral force resisting systems: High performance structures for the city of tomorrow.” Buildings, 4(3), 520–548.
Christenson, R. E., Johnson, E. A., and Spencer, B. F. (2007). “Semiactive connected control method for adjacent multidegree-of-freedom buildings.” J. Eng. Mech., 290–298.
Deb, K., Pratap, A., Agarwal, S., and Meyarivan, T. (2002). “A fast and elitist multiobjective genetic algorithm: NSGA-II.” IEEE Trans. Evol. Comput., 6(2), 182–197.
Elkady, A., and Lignos, D. G. (2015). “Effect of gravity framing on the overstrength and collapse capacity of steel frame buildings with perimeter special moment frames.” Earthquake Eng. Struct. Dyn., 44(8), 1289–1307.
Faravelli, L., and Casciati, S. (2008). “Structural control toward structural robustness.” 14th World Conf. on Earthquake Engineering, International Association for Earthquake Engineering, Tokyo.
FEMA. (2000). “State of the art report on systems performance of steel moment frames subject to earthquake ground shaking.”, Washington, DC.
FEMA. (2009). “Quantification of building seismic performance factors.”, Washington, DC.
Genta, G. (2009). Vibration dynamics and control, Springer, New Delhi, India.
Goldstein, H., Poole, C. P., Jr., and Safko, J. L. (2001). Classical mechanics, 3rd Ed., Addison-Wesley, San Francisco.
Kasagi, M., Fujita, K., Tsuji, M., and Takewaki, I. (2016). “Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection.” Heliyon, 2(2), e00069.
MATLAB [Computer software]. MathWorks, Natick, MA.
Murase, M., Tsuji, M., and Takewaki, I. (2013). “Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection.” Earthquake Struct., 4(6), 649–670.
Nishihara, O., and Matsuhisa, H. (1997). “Design optimization of passive gyroscopic damper (stability degree maximization).” JSME Int. J. Ser. C, 40(4), 643–651.
Pan, P., Wu, S., and Nie, X. (2015). “A distributed parameter model of a frame pin-supported wall structure.” Earthquake Eng. Struct. Dyn., 44(10), 1643–1659.
PEER NGA (Pacific Earthquake Engineering Research Center Next Generation Attenuation models). (2016). “PEER ground motion database.” ⟨http://peer.berkeley.edu/nga⟩ (Dec. 18, 2016).
Qu, Z., Wada, A., Motoyui, S., Sakata, H., and Kishiki, S. (2012). “Pin-supported walls for enhancing the seismic performance of building structures.” Earthquake Eng. Struct. Dyn., 41(14), 2075–2091.
Shinozaki, Y., Komuro, T., Fujino, H., Kawamoto, S. I., and Hosozawa, O. (2008). “Development of response control system with intensive energy absorption devices and application to building.” AIJ J. Technol. Des., 14(28), 453–458.
Skinner, R. I., Kelly, J. M., and Heine, A. J. (1974). “Hysteretic dampers for earthquake-resistant structures.” Earthquake Eng. Struct. Dyn., 3(3), 287–296.
Spencer, B. F., and Dyke, S. J. (1998). “Next generation benchmark control problems for seismically excited buildings.” Proc., 2nd World Conf. on Structural Control, Vol. 2, European Association for the Control of Structures, Pavia, Italy, 1135–1360.
Tagawa, H., Macrae, G., and Lowes, L. (2010). “Continuous columns effects of gravity columns in U.S. steel moment-resisting frame structures: Continuous column effects in steel moment frames in perspective of dynamic stability.” J. Struct. Constr. Eng., 75(650), 761–770 (in Japanese).
Taniguchi, M., Fujita, K., Tsuji, M., and Takewaki, I. (2016). “Hybrid control system for greater resilience using multiple isolation and building connection.” Front. Built Environ., 2(Oct), 1–10.
Tsampras, G., et al. (2016). “Development of deformable connection for earthquake-resistant buildings to reduce floor accelerations and force responses.” Earthquake Eng. Struct. Dyn., 45(9), 1473–1494.
Wiebe, L., and Christopoulos, C. (2009). “Mitigation of higher mode effects in base-rocking systems by using multiple rocking sections.” J. Earthquake Eng., 13(S1), 83–108.
Xiang, P., and Nishitani, A. (2014). “Seismic vibration control of building structures with multiple tuned mass damper floors integrated.” Earthquake Eng. Struct. Dyn., 43(6), 909–925.
Xiang, P., and Nishitani, A. (2015a). “Optimum design and application of non-traditional tuned mass damper toward seismic response control with experimental test verification.” Earthquake Eng. Struct. Dyn., 44(13), 2199–2220.
Xiang, P., and Nishitani, A. (2015b). “Optimum design of tuned mass damper floor system integrated into bending-shear type building based on H∞, H2, and stability maximization criteria.” Struct. Control Health Monit., 22(6), 919–938.
Xiang, P., and Nishitani, A. (2016). “Structural vibration control with the implementation of a pendulum-type nontraditional tuned mass damper system.” J. Vib. Control, 1–19.
Xiang, P., Nishitani, A., and Wu, M. (2017). “Seismic vibration and damage control of high-rise structures with the implementation of a pendulum-type nontraditional tuned mass damper.” Struct. Control Health Monit., 1–19.
Zhang, D., et al. (2014). “Development of a floor inertia force limiting anchorage system under earthquake loading.” Proc., 10th National Conf. on Earthquake Engineering, Earthquake Engineering Research Institute, Oakland, CA.
Zibaei, H., and Mokari, J. (2014). “Evaluation of seismic behavior improvement in RC MRFs retrofitted by controlled rocking wall systems.” Struct. Des. Tall Spec. Build., 23(13), 995–1006.
Information & Authors
Information
Published In
Copyright
©2017 American Society of Civil Engineers.
History
Received: Mar 6, 2017
Accepted: Jul 20, 2017
Published online: Nov 22, 2017
Published in print: Feb 1, 2018
Discussion open until: Apr 22, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.