Technical Papers
Sep 12, 2014

Steel Bridge Girder Strengthening Using Postinstalled Shear Connectors and UHM CFRP Laminates

Publication: Journal of Performance of Constructed Facilities
Volume 29, Issue 5

Abstract

A number of steel girder-RC bridges built in the past have noncomposite bridge decks. Many currently have load postings because of increased traffic loads. The main objective of this case study was the performance evaluation of a single span steel girder bridge with a noncomposite RC deck before and after strengthening using postinstalled shear studs and ultra high modulus (UHM) carbon-fiber-reinforced polymer (CFRP) laminates. The postinstalled shear studs were used to obtain a partial composite action between the concrete deck and steel girders to increase the load-carrying capacity and utilize the UHM CFRP laminates more efficiently. An AASHTO load-rating analysis carried out for an interior girder under an HS25 truck load showed an inventory level rating factor of 0.46 for the noncomposite bridge. Field tests were conducted before and after the installation of the shear studs and UHM CFRP laminates to determine the increase in the load-carrying capacity and reduction in maximum deflection. A finite-element model of the bridge was developed to validate the experimental data and analyze the bridge under varying wheel loads. Postinstalled shear studs are found to be capable of significantly increasing the load-carrying capacity of noncomposite bridges. The use of UHM CFRP laminates strengthened the steel bridge girders, reduced overall deflections, and increased the load-carrying capacity. The postinstalled shear studs and UHM CFRP laminates increased the load rating and removed the load posting on the bridge.

Get full access to this article

View all available purchase options and get full access to this article.

References

AASHTO. (2008). The manual for bridge evaluation, 1st Ed., Washington, DC.
AASHTO. (2010). LRFD bridge design specifications, 5th Ed., Washington, DC.
American National Standards Institute (ANSI)/AISC. (2010). Specification for structural steel buildings, American Institute of Steel Construction, Chicago.
ANSYS 12.0.1 [Computer software]. Canonsburg, PA, Ansys.
Dawood, M., Rizkalla, S., and Sumner, E. (2007). “Fatigue and overloading behavior of steel-concrete composite flexural members strengthened with high modulus CFRP materials.” J. Compos. Constr., 659–669.
Dedic, D. J., and Klaiber, F. W. (1984). “High-strength bolts as shear connectors in rehabilitation work.” Concr. Int., 6(7), 41–46.
He, J., Liu, Y., Chen, A., and Yoda, T. (2010). “Experimental study on inelastic mechanical behaviour of composite girders under hogging moment.” J. Constr. Steel Res., 66(1), 37–52.
Hollaway, L. C., and Cadei, J. (2002). “Progress in the technique of upgrading metallic structures with advanced polymer composites.” Prog. Struct. Eng. Mater., 4(2), 131–148.
Kwon, G. (2008). “Strengthening existing steel bridge girders by the use of post-installed shear connectors.” Ph.D. dissertation, Dept. of Civil, Architectural and Environmental Engineering, Univ. of Texas at Austin, Austin, TX.
Kwon, G., et al. (2009a). Strengthening existing non-composite steel bridge girders using post-installed shear connectors, Center for Transportation Research, Univ. of Texas at Austin, Austin, TX.
Kwon, G., Engelhardt, M. D., and Klingner, R. E. (2009b). Implementation project: Strengthening of a bridge near Hondo, Texas using post-installed shear connectors, Center for Transportation Research, Univ. of Texas at Austin, Austin, TX.
Kwon, G., Engelhardt, M. D., and Klingner, R. E. (2010). “Behavior of post-installed shear connectors under static and fatigue loading.” J. Constr. Steel Res., 66(4), 532–541.
Lee, P.-G., Shim, C.-S., and Chang, S.-P. (2005). “Static and fatigue behavior of large stud shear connectors for steel–concrete composite bridges.” J. Constr. Steel Res., 61(9), 1270–1285.
Miller, T. C., Chajes, M. J., Mertz, D. R., and Hastings, J. N. (2001). “Strengthening of a steel bridge girder using CFRP plates.” J. Bridge Eng., 514–522.
Moy, S. (2001). ICE design and practice guides—FRP composites life extension and strengthening of metallic structures, Thomas Telford, London.
Moy, S. S. J., and Bloodworth, A. G. (2007). “Strengthening a steel bridge with CFRP composites.” ICE Proc. Struct. Build., 160(2), 81–93.
National Research Council. (2007). “Guidelines for the design and construction of externally bonded FRP systems for strengthening existing structures.”, Rome.
Ollgaard, J. G., Slutter, R. G., and Fisher, J. W. (1971). “Shear strength of stud shear connectors in lightweight and normal-weight concrete.” AISC Eng. J., 8(2), 55–64.
Peiris, N. A. (2011). “Steel beams strengthened with ultra-high modulus CFRP laminates.” Ph.D. dissertation, Univ. of Kentucky, Lexington, KY.
Phares, B. M., Wipf, T. J., Klaiber, F. W., Abu-Hawash, A., and Lee, Y.-S. (2003). “Strengthening of steel girder bridges using FRP.” Proc., 2003 Mid-Continent Transportation Research Symp., Iowa State Univ., Ames, IA, 1–12.
Red Head. (2014). “Epcon A7 acrylic adhesive performance data.” 〈http://www.itwredhead.com/pdfs/submittals/A7_sub.pdf〉 (Mar. 10, 2014).
Schnerch, D., Dawood, M., Rizkalla, S., and Sumner, E. (2007). “Proposed design guidelines for strengthening of steel bridges with FRP materials.” Constr. Build. Mater., 21(5), 1001–1010.
Schnerch, D., and Rizkalla, S. (2008). “Flexural strengthening of steel bridges with high modulus CFRP strips.” J. Bridge Eng., 192–201.
Shim, C.-S., Lee, P.-G., and Yoon, T.-Y. (2004). “Static behavior of large stud shear connectors.” Eng. Struct., 26(12), 1853–1860.
Valente, I. B., and Cruz, P. J. S. (2009). “Experimental analysis of shear connection between steel and lightweight concrete.” J. Constr. Steel Res., 65(10–11), 1954–1963.
Zhao, X. L., and Zhang, L. (2007). “State of the art review on FRP strengthened steel structures.” Eng. Struct., 29(8), 1808–1823.

Information & Authors

Information

Published In

Go to Journal of Performance of Constructed Facilities
Journal of Performance of Constructed Facilities
Volume 29Issue 5October 2015

History

Received: Dec 9, 2013
Accepted: May 6, 2014
Published online: Sep 12, 2014
Discussion open until: Feb 12, 2015
Published in print: Oct 1, 2015

Permissions

Request permissions for this article.

Authors

Affiliations

A. Peiris, M.ASCE [email protected]
Research Engineer, Kentucky Transportation Center, Univ. of Kentucky, Lexington, KY 40506 (corresponding author). E-mail: [email protected]
I. Harik, M.ASCE
Professor, Dept. of Civil Engineering, Univ. of Kentucky, Lexington, KY 40506.

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share