Flexural and Serviceability Behavior of Concrete Beams Reinforced with Ribbed GFRP Bars
Publication: Journal of Composites for Construction
Volume 26, Issue 5
Abstract
Glass fiber-reinforced polymer (GFRP) bars are used as internal reinforcement in many structural applications. The structural performance of GFRP-reinforced concrete elements is dependent on the physical and mechanical properties of GFRP reinforcement. There is a lack of experimental data on the flexural behavior of concrete beams reinforced with ribbed GFRP bars. This study evaluates the flexural strength and serviceability performance of concrete beams reinforced with ribbed GFRP bars. A total of 11 GFRP-reinforced concrete beams with dimensions of 4,350 × 400 × 200 mm (length × height × width) were constructed and tested under a four-point loading test setup. The main test parameters were the concrete cover, reinforcement ratio, bar spacing, and confinement due to the transverse reinforcement in the bending zone. The results uantify the effect of increasing the reinforcement ratio on the increase in the ultimate capacity and the reduction in deflection at the service and ultimate stages. In addition, the results showed that the increase in the confinement in the bending zone due to closely spaced stirrups resulted in a higher ductility index and ultimate capacity with no considerable effect on the postcracking stiffness of the beams. Moreover, based on the experimental results, the accuracy of deflection equations available in design codes and guidelines is evaluated and discussed.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The authors acknowledge the Natural Sciences and Engineering Research Council of Canada (NSERC) and MST Rebar Inc. (formerly B&B FRP Manufacturing Inc.) for their financial support. The authors thank the technicians in the structures laboratory at Concordia University for their assistance during the experimental work. The first author acknowledge the support of Mr. Islam Elsayed Nagy during the testing phase of this study.
Notation
The following symbols are used in this paper:
- a
- shear span measured from the center of the support to the point load;
- Af
- total area of the GFRP bars;
- b
- width of the rectangular cross section;
- c
- distance from the extreme compression fibers to the neutral axis;
- Cc
- curvature factor in the deformation-based approach;
- Cd
- deflection factor in the deformation-based approach;
- Cs
- ductility strength factor;
- d
- distance from the extreme compression fibers to the center of the tensile reinforcement;
- Ec
- concrete modulus of elasticity;
- Ee
- elastic absorbed energy;
- Ef
- GFRP reinforcement elastic modulus;
- Et
- total absorbed energy;
- specified compressive strength of the concrete;
- ffu
- design tensile strength of the GFRP bars;
- fr
- concrete tensile strength;
- Icr
- transformed moment of inertia of the equivalent cracked concrete section;
- Ie
- effective moment of inertia of the cross section;
- Ig
- gross moment of inertia of the cross section;
- J
- deformability performance factor;
- k
- ratio between the neutral axis and reinforcement depths;
- L
- support-to-support span of the member;
- Lg
- distance measured from the support to the cracking moment point in a simply supported beam;
- Ma
- applied moment on the member;
- Mc
- moment at a concrete compressive strain of 0.001;
- Mcr
- cracking moment;
- Ms
- moments at different serviceability limit states;
- Mult
- ultimate moment capacity of the section;
- nf
- ratio between the GFRP and concrete elastic moduli;
- P
- acting load on the member;
- P1
- cracking load;
- P2
- load at the beginning of concrete compression crushing in the overreinforced sections;
- S1
- initial slope of the loading curve before cracking;
- S2
- secant slope of the moment–deflection curve after cracking;
- S3
- unloading slope of the elastic region from the failure point;
- yb
- distance from the extreme tensile concrete fibers to the neutral axis;
- α1
- ratio of the average of the equivalent stress block to the concrete compressive strength;
- β1
- factor converting the actual stress diagram along the cross section to an equivalent rectangular stress block;
- βc
- tension stiffening factor;
- γ
- factor accounting for the variation in stiffness along the member length;
- δmax
- maximum midspan deflection at the applied load;
- Δu
- maximum deflection at the ultimate moment;
- Δɛ = 0.001
- deflection at a concrete compressive strain of 0.001;
- ɛc
- concrete compressive strain at any acting moment;
- ɛcu
- ultimate concrete compressive strain;
- ɛf
- GFRP tensile strain at any acting moment;
- η
- ratio of the difference between the gross and cracked moment of inertia to the gross moment of inertia;
- μd
- deformation-based ductility index;
- μe
- energy-based ductility index;
- ρfb
- balanced reinforcement ratio;
- φm
- curvature of the beam;
- φu
- curvature at the ultimate moment;
- φɛ = 0.001
- curvature at a concrete compressive strain of 0.001;
- ψc
- curvature at a concrete compressive strain of 0.001; and
- ψult
- curvature at the ultimate moment.
References
AASHTO. 2018. AASHTO LRFD bridge design specifications guide for design-build procurement. Washington, DC: AASHTO.
Abdelkarim, O. I., E. A. Ahmed, H. M. Mohamed, and B. Benmokrane. 2019. “Flexural strength and serviceability evaluation of concrete beams reinforced with deformed GFRP bars.” Eng. Struct. 186: 282–296. https://doi.org/10.1016/j.engstruct.2019.02.024.
ACI (American Concrete Institute). 2006. Guide for the design and construction of structural concrete reinforced with Fiber-Reinforced Polymer (FRP) bars. ACI 440.1R-06. Farmington Hills, MI: ACI.
ACI (American Concrete Institute). 2015. Guide for the design and construction of structural concrete reinforced with fiber-reinforced polymer bars. ACI 440.1R-15. Farmington Hills, MI: ACI.
ACI (American Concrete Institute). 2019. Building code requirements for structural concrete. ACI 318. Farmington Hills, MI: ACI.
Al-Sunna, R., K. Pilakoutas, I. Hajirasouliha, and M. Guadagnini. 2012. “Deflection behaviour of FRP reinforced concrete beams and slabs: An experimental investigation.” Composites, Part B 43 (5): 2125–2134. https://doi.org/10.1016/j.compositesb.2012.03.007.
ASTM. 2017a. Standard specification for solid round glass fiber reinforced polymer bars for concrete reinforcement. ASTM D7957/D7957M-17. West Conshohocken, PA: ASTM.
ASTM. 2017b. Standard test method for splitting tensile strength of cylindrical concrete specimens. ASTM C496/C496M-17. West Conshohocken, PA: ASTM.
ASTM. 2020. Standard test method for slump of hydraulic-cement concrete. ASTM C143/C143M-20. West Conshohocken, PA: ASTM.
ASTM. 2021a. Standard test method for tensile properties of fiber reinforced polymer matrix composite bars. ASTM D7205/D7205M. West Conshohocken, PA: ASTM.
ASTM. 2021b. Standard test method for compressive strength of cylindrical concrete specimens. ASTM C39/C39M-21. West Conshohocken, PA: ASTM.
ASTM. 2021c. Standard test method for flexural strength of concrete (using simple beam with third-point loading). ASTM C78/C78M-21. West Conshohocken, PA: ASTM.
Baena, M., L. Torres, A. Turon, and C. Barris. 2009. “Experimental study of bond behaviour between concrete and FRP bars using a pull-out test.” Composites, Part B 40 (8): 784–797. https://doi.org/10.1016/j.compositesb.2009.07.003.
Benmokrane, B., V. L. Brown, K. Mohamed, A. Nanni, M. Rossini, and C. Shield. 2019. “Creep-rupture limit for GFRP bars subjected to sustained loads.” J. Compos. Constr. 23 (6): 06019001. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000971.
Benzecry, V., A. Ruiz Emparanza, F. De Casoy Basalo, and A. Nanni. 2021. “Bond coefficient, kb, of GFRP bars.” Constr. Build. Mater. 292: 123380. https://doi.org/10.1016/j.conbuildmat.2021.123380.
Bischoff, P. H. 2005. “Reevaluation of deflection prediction for concrete beams reinforced with steel and fiber reinforced polymer bars.” J. Struct. Eng. 131 (5): 752–767. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:5(752).
Bischoff, P. H., S. Gross, and C. E. Ospina. 2009. “The story behind proposed changes to ACI 440 deflection requirements for FRP-reinforced concrete.” Am. Concr. Inst. Spec. Publ. 264: 53–76.
Bischoff, P. H., and S. P. Gross. 2011a. “Equivalent moment of inertia based on integration of curvature.” J. Compos. Constr. 15 (3): 263–273. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000164.
Bischoff, P. H., and S. P. Gross. 2011b. “Design approach for calculating deflection of FRP-reinforced concrete.” J. Compos. Constr. 15 (4): 490–499. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000195.
Branson, D. E. 1965. Instantaneous and time-dependent deflections of simple and continuous reinforced concrete beams. HPR Rep. No. 7, Part 1. Montgomery, AL: State of Alabama Highway Dept., Bureau of Research and Development.
CSA (Canadian Standard Association). 2012. Design and construction of building structures with fibre reinforced polymers. CAN/CSA S806 (R2017). Rexdale, ON, Canada: CSA.
CSA (Canadian Standard Association). 2014. Canadian highway bridge design code. CAN/CSA S6. Rexdale, ON, Canada: CSA.
El-Nemr, A., E. A. Ahmed, C. Barris, and B. Benmokrane. 2016. “Bond-dependent coefficient of glass- and carbon-FRP bars in normal- and high-strength concretes.” Constr. Build. Mater. 113: 77–89. https://doi.org/10.1016/j.conbuildmat.2016.03.005.
El-Nemr, A., E. A. Ahmed, and B. Benmokrane. 2013. “Flexural behavior and serviceability of normal- and high-strength concrete beams reinforced with glass fiber-reinforced polymer bars.” ACI Struct. J. 110 (6): 1077–1087.
El-Nemr, A., E. A. Ahmed, A. El-Safty, and B. Benmokrane. 2018. “Evaluation of the flexural strength and serviceability of concrete beams reinforced with different types of GFRP bars.” Eng. Struct. 173: 606–619. https://doi.org/10.1016/j.engstruct.2018.06.089.
ISIS (Intelligent Sensing for Innovative Structures) Canada. 2007. Reinforcing concrete structures with fibre reinforced polymers. ISIS-M03-07. Winnipeg, MB, Canada: Canadian Network of Centers of Excellence on Intelligent Sensing for Innovative Structures, Univ. of Winnipeg.
Jaeger, G. L., G. Tadros, and A. A. Mufti. 1997. “The concept of the overall performance factor in rectangular-section reinforced concrete beams.” In Vol. 2 of Proc., 3rd Int. Symp. on Non-Metallic Firber-Reinforced Polymer Reinforcement for Concrete Structures, 551–558. New York: Springer.
Kassem, C., A. S. Farghaly, and B. Benmokrane. 2011. “Evaluation of flexural behavior and serviceability performance of concrete beams reinforced with FRP bars.” J. Compos. Constr. 15 (5): 682–695. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000216.
McCallum, B. 2013. “Experimental evaluation of the bond dependent coefficient and parameters which influence crack width in GFRP reinforced concrete.” M.S. thesis, Dept. of Civil and Resource Engineering, Dalhousie Univ.
Mias, C., L. Torres, A. Turon, and C. Barris. 2013. “Experimental study of immediate and time-dependent deflections of GFRP reinforced concrete beams.” Compos. Struct. 96: 279–285. https://doi.org/10.1016/j.compstruct.2012.08.052.
Mousa, S., H. M. Mohamed, B. Benmokrane, and A. Nanni. 2020. “Flexural behavior of long- span square reinforced concrete members with uniformly distributed fiber- reinforced polymer bars.” ACI Struct. J. 117 (4): 209–222.
Naaman, A. E., and S. M. Jeong. 1995. “Structural ductility of concrete beams prestressed with FRP tendons.” In Non-metallic (FRP) reinforcement for concrete structures, edited by L. Taewere, 379–386. London: E. & F.N. Spon.
Newhook, J., A. Ghali, and G. Tadros. 2002. “Concrete flexural members reinforced with fiber reinforced polymer: Design for cracking and deformability.” Can. J. Civ. Eng. 29 (1): 125–134. https://doi.org/10.1139/l01-085.
Rao, P. S. 1966. Basic laws governing moment redistribution in statically indeterminate reinforced concrete structures!. Berlin: DAfStb, Ernst & Sohn.
Solyom, S., and G. L. Balázs. 2018. “Comparitive study of bond behaviour for different FRP and steel bars.” In Proc., 12th fib Int. Ph.D. Symp. in Civil Engineering, 153–160. Lausanne, Switzerland: CEB FIB.
Solyom, S., and G. L. Balázs. 2020. “Bond of FRP bars with different surface characteristics.” Constr. Build. Mater. 264: 119839. https://doi.org/10.1016/j.conbuildmat.2020.119839.
Vijay, P. V., and H. V. S. GangaRao. 2001. “Bending behavior and deformability of GFRP reinforced concrete members.” ACI Struct. J. 98 (6): 834–842.
Wang, H., and A. Belarbi. 2011. “Ductility characteristics of fiber-reinforced-concrete beams reinforced with FRP rebars.” Constr. Build. Mater. 25 (5): 2391–2401. https://doi.org/10.1016/j.conbuildmat.2010.11.040.
Xue, W., F. Peng, and Q. Zheng. 2016. “Design equations for flexural capacity of concrete beams reinforced with glass fiber–reinforced polymer bars.” J. Compos. Constr. 20 (3): 04015069. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000630.
Yost, J. R., S. P. Gross, and D. W. Dinehart. 2003. “Effective moment of inertia for glass fiber-reinforced polymer-reinforced concrete beams.” ACI Struct. J. 100 (6): 732–739.
Information & Authors
Information
Published In
Copyright
© 2022 American Society of Civil Engineers.
History
Received: Dec 21, 2021
Accepted: May 26, 2022
Published online: Aug 9, 2022
Published in print: Oct 1, 2022
Discussion open until: Jan 9, 2023
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.
Cited by
- Omar Gouda, Ahmed Hassanein, Khaled Galal, Experimental and numerical study on the crack width and deflection performance of GFRP reinforced concrete beams, Engineering Structures, 10.1016/j.engstruct.2023.115721, 283, (115721), (2023).