Experimental Performance of AFRP Concrete Bridge Deck Slab with Full-Depth Precast Prestressed Panels
Publication: Journal of Bridge Engineering
Volume 19, Issue 4
Abstract
While application of full-depth precast bridge deck panels may be appealing because of an accelerated construction schedule and improved safety conditions, corrosion of steel reinforcement is a major factor affecting the structural durability of precast panels and overall serviceability of a bridge deck. Herein, the concept of using aramid fiber reinforced polymer (AFRP) bars as a substitute for conventional steel reinforcement to overcome corrosion issues is verified. For this purpose, a full-scale bridge deck slab consisting of full-depth precast panels reinforced and prestressed with AFRP bars is constructed and experimentally evaluated in terms of load capacity, deformation, crack pattern, and failure mode. The precast panels are reinforced and prestressed in parallel and perpendicular to the traffic directions, respectively, and supported by reinforced concrete beams. Realistic dimensions, boundary conditions, and structural details are physically modeled to represent an actual bridge deck condition, and different concentrated load configurations including wheel and tandem axle loads are applied on both the slab interior span and overhang. The experimental results show the average failure load of the interior spans and overhangs, respectively equal to 3.9 and 1.4 times the maximum factored wheel load, where the deflection serviceability criteria are met and satisfactory deformability performance is achieved.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by a grant from the National Science Foundation (NSF 0927333). The authors would like to express appreciation for the generous support from NSF to conduct this research. The findings and opinions presented herein are those of the authors and are not necessarily those of the sponsoring agency. The support provided by the High-Bay Structural and Materials Testing Laboratory at Texas A&M University, where the experimental investigation was conducted, is greatly appreciated.
References
AASHTO. (2010). “Bridge design specification.” AASHTO LRFD, 5th Ed., Washington, DC.
American Concrete Institute (ACI). (2004). “Prestressing concrete structures with FRP tendons.” 440.4R-04, Detroit.
American Concrete Institute (ACI). (2006). “Guide for the design and construction of structural concrete reinforced with FRP bars.” 440.1R-06, Detroit.
ASTM. (2008a). “Standard test method for compressive strength of grouts for preplaced-aggregate concrete in the laboratory.” C942, West Conshohocken, PA.
ASTM. (2008b). “Standard test method for flow of grout for preplaced-aggregate concrete.” C939, West Conshohocken, PA.
ASTM. (2008c). “Standard test method for flow table for use in tests of hydraulic cement.” C230/C230M, West Conshohocken, PA.
Benmokrane, B., El-Salakawy, E., Desgagne, G., and Lackey, T. (2004). “FRP bars for bridges.” Concr. Int., 26(8), 84–90.
Canadian Standards Association (CSA). (2006). “Canadian highway bridge design code.” CSA S6-06, Toronto.
Chen, Y. (2007). “Accelerated aging tests and long-term prediction models for durability of FRP bars in concrete.” Ph.D. thesis, College of Engineering and Mineral Resources, West Virginia Univ, Morgantown, WV.
Deitz, D. H., Harik, I. E., and Gesund, H. (1999). “One-way slabs reinforced with glass fiber reinforced polymer reinforcing bars.” Proc., 4th Int. Symp., Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures, C. W. Dolan, S. H. Rizkalla, and A. Nanni, eds., American Concrete Institute, Farmington Hills, MI, 279–286.
El-Salakawy, E., and Benmokrane, B. (2004). “Serviceability of concrete bridge deck slabs reinforced with fiber-reinforced polymer composite bars,” ACI Struct. J., 101(5), 727–736.
El-Sayed, A., El-Salakawy, E., and Benmokrane, B. (2005). “Shear strength of one-way concrete slabs reinforced with fiber-reinforced polymer composite bars.” J. Compos. Constr., 147–157.
Gamal, S., El-Salakawy, E., and Benmokrane, B. (2005). “Behavior of concrete bridge deck slabs reinforced with fiber-reinforced polymer bars under concentrated loads,” ACI Struct. J., 102(5), 727–735.
Hassan, T., Abdelrahman, A., Tadros, G., and Rizkalla, S. (2000). “Fibre reinforced polymer reinforcing bars for bridge decks.” Can. J. Civ. Eng., 27(5), 839–849.
Issa, M. A., Yousif, A. A., and Issa, M. A. (2000). “Experimental behavior of full-depth precast concrete panels for bridge rehabilitation,” ACI Struct. J., 97(3), 397–407.
Mander, T. J. (2009). “Structural performance of a full scale precast concrete bridge deck system.” M.S. thesis, Texas A&M Univ., College Station, TX.
Mander, T. J., Henley, M. D., Scott, R. M., Head, M. H., and Mander, J. B. (2010). “Experimental performance of full-depth precast, prestressed concrete overhang, bridge deck panels.” J. Bridge Eng., 503–510.
Mander, T. J., Mander, J. B., and Head, M. H. (2011). “Compound shear-flexural capacity of reinforced concrete-topped precast prestressed bridge decks.” J. Bridge Eng., 4–11.
Medina, J. C. (2011). “Characteristics of AFRP bars for prestressing applications.” M.S. thesis, Texas A&M Univ., College Station, TX.
Michaluk, C. R., Rizkalla, S. H., Tadros, G., and Benmokrane, B. (1998). “Flexural behavior of one-way concrete slabs reinforced by fiber reinforced plastic reinforcement.” ACI Struct. J., 95(3), 353–365.
Pirayeh Gar, S. (2012). “Structural performance of a full-depth precast bridge deck system prestressed and reinforced with AFRP bars.” Ph.D. thesis, Texas A&M Univ., College Station, TX.
Pirayeh Gar, S., Head, M., and Hurlebaus, S. (2013a). “Computational modeling of aramid fiber-reinforced polymer prestressed girder in composite action with bridge deck.” ACI Struct. J., 110(6), 965–976.
Pirayeh Gar, S., Head, M., Hurlebaus, S., and Mander, J. (2013b). “Comparative experimental performance of bridge deck slabs with AFRP and steel precast panels.” J. Compos. Constr., 04013014.
Rahman, A. H., Kingsley, C. Y., and Kobayashi, K. (2000). “Service and ultimate load behavior of bridge deck reinforcement with carbon FRP grid.” J. Compos. Constr., 16–23.
Rizkalla, S., and Tadros, G. (1994). “A smart highway bridge in Canada.” Concr. Int., 16(6), 42–44.
Soroushian, P., Ravanbakhsh, S., and Nagi, M. A. (2002). “Laboratory evaluation and field application of concrete reinforcement with aramid fiber-reinforced polymer bars.” ACI Mater. J., 99(6), 584–590.
Taerwe, L., ed. (1995). “Non-metalic (FRP) reinforcement for concrete structures.” Proc., 2nd Int. RILEM Symp., FRPRCS-2, E & FN SPON, London.
Trejo, D., Aguiniga, C., Buth, E., Yuan, R., James, R. W., and Keating, P. (2000). “Reinforcing bars in bridge decks: State-of-the-art review.” Res. Rep. 1520-2, Texas Transportation Institute (TTI), College Station, TX.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: May 1, 2013
Accepted: Sep 23, 2013
Published online: Sep 25, 2013
Published in print: Apr 1, 2014
Discussion open until: May 17, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.