Hybrid Bonding of FRP to Reinforced Concrete Structures
Publication: Journal of Composites for Construction
Volume 12, Issue 3
Abstract
The adhesive attachment of fiber-reinforced polymers (FRP) laminate to the external face of reinforced concrete structures is currently one of the most popular and effective methods for retrofitting and strengthening concrete structures. With this method, the additional strength of the attached reinforcement is transmitted into the concrete members through adhesion. However, the relatively weak adhesive interface fundamentally limits the efficacy of the method. Much effort has been made in the research community to improve the bond strength and develop bond models, but a satisfactory solution has yet to be found. Mechanical fastening is another more traditional technology that is used to bond one material to another. This paper introduces a new hybrid bonding technique that combines adhesive bonding and a new type of mechanical fastening. The new mechanical fastening technique does not rely on bearing to transmit the interfacial shear, but instead increases the interfacial bond by resisting the separation of the FRP laminate from the concrete substrate. Experimental tests demonstrated that the bond strength with this new hybrid bonding technology was 7.5 times that of conventional adhesive bonding. Furthermore, the new bonding technique is applicable to all types of commercially available FRP laminate (fabric, sheet, plate, and strip), and in principle is also applicable to materials other than FRP.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The work that is described in this paper was fully supported by a grant from the Research Grants Council of the Hong Kong Special Administrative Region, China (Project No. UNSPECIFIEDCityU 1113/04E).
References
Antoniades, K. K., Salonikios, T. N., and Kappos, A. J. (2003) “Cyclic tests on seismically damaged reinforced concrete walls strengthened using fiber-reinforced polymer reinforcement.” ACI Struct. J., 100(4), 510–518.
Antoniades, K. K., Salonikios, T. N., and Kappos, A. J. (2005). “Tests on seismically damaged reinforced concrete walls repaired and strengthened using fiber-reinforced polymers.” J. Compos. Constr., 9(3), 236–246.
Bank, L. C. (2004) “Mechanically fastened FRP (MF-FRP)—A viable alternative for strengthening RC members.” Proc., 2nd Int. Conf. on FRP Composites in Civil Engineering (CICE 2004), Adelaide, Australia.
Garden, H. N., and Holloway, L. C. (1998). “An experimental study of the influence of plate end anchorage of carbon fiber composite plates used to strengthen reinforced concrete beams.” Compos. Struct., 42, 175–188.
Grace, N. F. (2001). “Improved anchoring system for CFRP strips.” Concr. Int., 23(10), 55–60.
Kanakubo, T., Aridome, Y., Fujita, N., and Matsui, M. (2000). “Development of anchorage system for CFRP sheet in strengthening of reinforced concrete structures.” Proc., 12th World Conf. on Earthquake Engineering, New Zealand, Paper No. 1831.
Lamanna, A. J., Bank, L. C., and Scott, D. W. (2004). “Flexural strengthening of reinforced concrete beams by mechanically attaching fiber-reinforced polymer strips.” J. Compos. Constr., 8(3), 203–210.
Lombard, J., Lau, D., Humar, J., Foo, S., and Cheung, M. (2000). “Seismic strengthening and repair of reinforced concrete shear walls.” Proc. 12th World Conf. on Earthquake Engineering, New Zealand, Paper No. 2032.
Nanni, A. (1995). “Concrete repair with externally bonded FRP reinforcement.” Concr. Int., 17(6), 22–26.
Saadatmanesh, H., and Ehsani, M. R. (1991). “RC beams strengthened with GFRP plates. I: Experimental study.” J. Struct. Eng., 117(11), 3417–3433.
Spadea, G., Bencardino, F., and Swamy, R. N. (1998) “Structural behavior of composite RC beams with externally bonded CFRP.” J. Compos. Constr., 2(23), 132–137.
Teng, J. G., Chen, J. F., Smith, S. T., and Lam, L. (2002). FRP strengthened RC structures, Wiley, Chichester, U.K.
Teng, J. G., Chen, J. F., Smith, S. T., and Lam, L. (2003). “Behavior and strength of FRP-strengthened RC structures: A state-of-the-art review.” Proc. Inst. Civ. Eng., Struct. Build., 156(3), 334–335.
Teng, J. G., Lam, L., Chan, W., and Wang, J. (2000). “Retrofitting of deficient RC cantilever slabs using GFRP strips.” J. Compos. Constr., 4(2), 75–84.
Tsoukantas, S. G., and Tassios, T. P. (1989). “Shear resistance of connections between reinforced concrete linear precast elements.” ACI Struct. J., 86(3), 242–249.
Wang, Z. Y., Wu, Y.-F., and He, W. (2007) “A numerical model for hybrid-bonded FRP strengthened beams.” Proc., 4th Cross-Strait Conf. on Structural and Geotechnical Engineering, Hangzhou, China, 503–517.
Wu, Z. S., and Yin, J. (2003). “Fracturing behaviour of FRP-strengthened concrete structures.” Eng. Fract. Mech., 70, 1339–1355.
Information & Authors
Information
Published In
Copyright
© 2008 ASCE.
History
Received: Jan 11, 2007
Accepted: Aug 13, 2007
Published online: Jun 1, 2008
Published in print: Jun 2008
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.