Assessing Corrosion on Steel Structures Using Corrosion Coulometer
Publication: Journal of Infrastructure Systems
Volume 2, Issue 3
Abstract
Corrosive exposure and subsequent deterioration of weathering steel structures cause strength loss due to cross-section thinning as well as crack susceptibility due to formation of notches that concentrate stresses. Key issues include rapidly drying versus extended wet time surfaces, the relationship of clean versus debris-covered surfaces to corrosion, and disparities between test site and service conditions. An adequate understanding of corrosion, corrosion's relationship to steel structure serviceability, and the ability to monitor, predict, and abate corrosion are important needs for weathering steel structures. To implement these needs, data on corrosive conditions were collected from corrosion coulometers placed on seven structures in varied environments, at one preconstruction site and at two corrosion test sites. An analysis of corrosion processes leading to cross-section thinning, notching, and loss of fatigue strength is presented. Improved service and maintenance, enhanced design methodologies, and cost savings are anticipated outcomes.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Fisher, J. W., Yen, B. T., and Wang, D. (1991). “Corrosion and its influence on strength of steel bridge members.”Transp. Res. Rec. No. 1290, 1, Bridges and Struct., 3rd Bridge Engrg. Conf., Transp. Res. Board, Nat. Res. Council, Washington, D.C., 211–219.
2.
Granata, R. D., Michalerya, W. D., Wildt, R. H., Leidheiser, H. Jr., and O'Malley, B. W. Jr. (1992). “Quantitative evaluation of steel corrosion in micro-environments using the corrosion coulometer.”Review of progress in quantitative nondestructive evaluation, 11, D. O. Thompson and D. E. Chimenti, eds., Plenum Press, New York, N.Y., 1183–1190.
3.
Horton, J. B. (1965). “The rusting of low alloy steels in the atmosphere,” presented at the San Francisco meeting, AISI, Nov. 8 (see also, Booklet 2385-A, Bethlehem Steel Corporation, Bethlehem, PA, 1971).
4.
O'Malley, B. W. Jr., and Granata, R. D. (1990). “Service testing of the corrosion monitor for bridges,”ATLSS Rep. No. 90-09, Lehigh Univ., Bethlehem, Pa.
5.
Pludek, V. R. (1977). Design and corrosion control . Halsted Press, New York, N.Y.
6.
Standard practice for G50-76: conducting atmospheric corrosion tests on metals; 03.02. (1992). ASTM, Philadelphia, Pa.
7.
Townsend, H., Simpson, T., and Johnson, G.(1993). “Structure of rust on weathering steels in rural and industrial environments.”Proc., 12th Int. Corrosion Cong. Corrosion Control for Low-Cost Reliability Conf., NACE, Int'l, Houston, TX, 2, 5, 624–641.
8.
Townsend, H. E., and Zoccola, J. C. (1982). “Eight-year atmospheric corrosion performance of weathering steel in industrial, rural, and marine environments.”Atmospheric Corrosion of Metals, ASTM STP 767, S. W. Dean Jr. and E. C. Rhea, eds., ASTM, Philadelphia, Pa., 45–59.
9.
“Uncoated weathering steel structures.” (1989). Tech. Advisory No. T5140.22, Fed. Hwy. Admin., Washington, D.C.
10.
White, M. L., and Leidheiser, H. Jr. (1988). “The corrosion coulometer—a new corrosion monitor for steel structures.”ATLSS Rep. No. 88-07, Lehigh Univ., Bethlehem, Pa.
11.
White, M. L., and Leidheiser, H. Jr.(1990). “The corrosion coulometer—a new corrosion monitor for steel structures.”Corrosion, 46(8), 653–661.
12.
Wilson, J. C., and Granata, R. D. (1994). “Service testing of the corrosion monitor for steel structure site evaluations.”ATLSS Rep. No. 94-12, Lehigh Univ., Bethlehem, Pa.
Information & Authors
Information
Published In
Copyright
Copyright © 1996 American Society of Civil Engineers.
History
Published online: Sep 1, 1996
Published in print: Sep 1996
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.