Corrosion of Galvanized Strips in Florida Reinforced Earth Walls
Publication: Journal of Materials in Civil Engineering
Volume 12, Issue 3
Abstract
The corrosion condition of the galvanized reinforcement in Florida Department of Transportation (FDOT) Mechanically Stabilized Earth Walls (MSEW) was determined at selected sites. For this purpose, 10 MSEW structures were instrumented at 8 different Florida sites for measurements of soil resistivity, electrical potential, and corrosion rates of both galvanized steel and plain steel by polarization resistance tests. The FDOT design standards for soil chemistry and particle size distribution were met in virtually all the test locations and structures tested. The reinforcements in the structures investigated were typically in good condition and the apparent corrosion rate of galvanized elements was low (average about 1 μm/year). A deterioration model for service life forecasting was formulated using the field survey input.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Castro, P., Sagüés, A., Moreno, E., Maldonado, L., and Genesca, J., (1996). (1996). “Characterization of activated titanium solid reference electrodes for corrosion testing of steel in concrete.” Corrosion, 52(8), 609.
2.
Chaker, V., and Palmer, J., eds. (1989). “Effect of soil characteristics on corrosion.” ASTM STP 1013, ASTM, West Conshohocken, Pa.
3.
Elias, V. (1990). “Durability/corrosion of soil reinforced structures.” Rep. No. FHWA-RD-89-186, National Technical Information Service, Springfield, Va.
4.
Florida Department of Transportation (FDOT). ( 1995). “Chapter 18: Retaining walls.” Structures design guidelines, Topic 625-020-150a, Revised April 3, Tallahassee, Fla.
5.
Mansfeld, F. ( 1976). “The polarization resistance technique.” Advances in corrosion science and technology, Vol. 6, M. Fontana and R. Staehle, eds., Plenum Press, New York.
6.
Mitchell, J. K., and Villet, W. C. B. (1987). “Reinforcement of earth slopes and embankments.” National Cooperative Highway Research Program Rep. 290, Transportation Research Board, National Research Council, Washington, D.C., 23–75.
7.
Sagüés, A., and Kranc, S. (1996). Techniques to assess the corrosion activity of steel reinforced structures: ASTM STP 1276, N. Berke, E. Escalante, C. Nmai, and D. Whiting, eds., ASTM, West Conshohocken, Pa., 58.
8.
Sagüés, A., Rossi, J., Scott, R., Peña, J. A., and Simmons, T. (1998). “Influence of corrosive inundation on the corrosion rates of galvanized tie strips in mechanically stabilized earth walls.” Rep. No. WPI0510686, Florida Department of Transportation Research Center, Tallahassee, Fla.
9.
Scully, J. R. (2000). “The polarization resistance method for determination of instantaneous corrosion rates.” Corrosion, 56(2), 199.
10.
Vidal, H. (1969). “The principle of reinforced earth.” Hwy. Res. Rec. No. 282, Highway Research Board, National Research Council, Washington, D.C., 1–24.
11.
Zhan, X. G. (1996). Corrosion and electrochemistry of zinc, Plenum Press, New York.
Information & Authors
Information
Published In
History
Received: Jan 28, 1999
Published online: Aug 1, 2000
Published in print: Aug 2000
Authors
Metrics & Citations
Metrics
Citations
Download citation