Public‐Safety Issues in Collapse of L'Ambiance Plaza
This article has a reply.
VIEW THE REPLYThis article has a reply.
VIEW THE REPLYThis article has a reply.
VIEW THE REPLYPublication: Journal of Performance of Constructed Facilities
Volume 5, Issue 2
Abstract
Investigations of the collapse of the partially completed L'Ambiance Plaza, a 16‐story residential project under construction in Bridgeport, Connecticut, revealed four major structural deficiencies that may have triggered the collapse, along with at least five other design or construction conditions that negatively impacted structural reliability. The major deficiencies were: improper drape of posttensioning tendons adjacent to elevator openings, overstressed concrete slab sections adjacent to two temporary floor slots for cast‐in‐place shear walls, overstressed and excessively flexible steel lifting angles during slab lifting, and unreliable and inadequate temporary slab‐column connections to assure frame stability. The existence of so many deficiencies in one project raises fresh concern whether public safety is being adequately protected in the U.S. system for design and construction of major buildings. This project used a design concept that transferred major design responsibilities to the contractor via performance specifications, permitted construction procedures that were not backed up by proof of adequacy for temporary conditions, and provided quality‐assurance measures that did not include adequate review by the engineer of record. These system deficiencies led to the collapse. Recommendations for improving U.S. regulatory and structural design practice to help avoid future disasters like L'Ambiance Plaza are given.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
“American national standard for construction and demolition operations—concrete and masonry work—safety requirements.” (1982). ANSI‐A10.9, Am. Nat. Standards Inst., New York, N.Y., 17.
2.
The BOCA national building code. (1986). Bldg. Officials and Code Administrators Int., Inc., Country Club Hills, Ill.
3.
“Building code requirements for reinforced concrete, with commentary.” (1983). ACI 318‐83, Am. Concr. Inst., Detroit, Mich.
4.
“Building code requirements for reinforced concrete, with commentary.” (1989). ACI 3J8R‐89, Am. Concr. Inst., Detroit, Mich.
5.
Burns, N. H., and Hemakon, R. (1985). “Test of post‐tensioned flat plate with banded tendons.” J. Struct. Engrg., ASCE, 111(9), 1899–1915.
6.
Design of post‐tensioned slabs. (1977). Post‐Tensioning Inst., Phoenix, Ariz.
7.
Hawkins, N. M. ( 1981 ). “ Lateral load resistance of unbonded post‐tensioned flat plate construction.” PCI J., 26 ( 1 ), 94 – 116.
8.
“Investigation of L'Ambiance Plaza building collapse in Bridgeport, Connecticut.” (1987). Report NBS1R 87‐3640, Nat. Bureau of Standards, Ctr. for Bldg. Tech., Nat. Engrg. Lab., U.S. Dept. of Commerce, Gaithersburg, Md.
9.
Kosut, G. M., Burns, N. M., and Winter, C. V. (1985). “Test of four‐panel post‐tensioned flat plate.” J. Struct. Engrg., ASCE, 111(9), 1916–1929.
10.
“Minimum design loads for buildings and other structures.” (1990). ASCE 7‐88, ASCE, New York, N.Y.
11.
Poston, R. W., Feldmann, G. C., and Suarez, M. G. (1991). “Evaluation of L'Ambiance Plaza posttensioned floor slabs.” J. Perf. Constr. Fac., ASCE, 5(2), 75–91.
12.
“Recommendations for concrete members prestressed with unbonded tendons.” (1989). ACI‐ASCE Committee 423, ACI Struct. J., 86(3), 301–318.
13.
Scribner, C. F., and Culver, G. G. (1988). “Investigation of the collapse of L'Ambiance Plaza.” J. Perf. Constr. Fac., ASCE, 2(2), 58–79.
14.
Wonder, D. R. (1988). “What happened at L'Ambiance Plaza.” Civ. Engrg., ASCE, Oct., 68–71.
Information & Authors
Information
Published In
Copyright
Copyright © 1991 ASCE.
History
Published online: May 1, 1991
Published in print: May 1991
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.