Effects of Axial Compression Load and Eccentricity on Seismic Behavior of Nonseismically Detailed Interior Beam-Wide Column Joints
Publication: Journal of Structural Engineering
Volume 135, Issue 7
Abstract
Six full-scale nonseismically detailed reinforced concrete interior beam-wide column joints were tested to investigate the seismic behavior of the joints. Axial compression loads varying from zero to high magnitude, as well as quasi-static cyclic loading simulating earthquake actions were applied. The overall performance of each test assembly was examined in terms of lateral load capacity, drift, stiffness, energy dissipation capacity, and joint shear strength. Three levels of axial compressive column load were investigated to determine how this variable might influence the performance of the joint. The tests also explored the effects of centerline eccentricity on the performance of interior beam-wide column joints subjected to earthquake loading. All the specimens failed at the joint panel with gradual strength deterioration, low attainment of structural stiffness, and bond degradation. The low attainment of stiffness and strength was attributed to the bond deterioration of the longitudinal bars through the joint core. It is concluded that special reinforced concrete interior beam-wide column joints with nonseismic design and detailing, could possess the inherent ductility for an adequate response to unexpected moderate earthquakes.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The financial assistance provided by the Building & Construction Authority and Ove Arup, Singapore, is gratefully acknowledged.
References
American Concrete Institute (ACI) Committee 318. (2002). Building code requirements for structural concrete (ACI 318–02) and commentary (ACI 318R-02), Farmington Hills, Mich.
Architectural Institute of Japan (AIJ). (1994). Design guidelines for earthquake resistant reinforced concrete buildings based on ultimate strength concept (drift) and commentary, Tokyo.
British Standards Institute (BSI). (1997). Structural use of concrete, Part 1. Code of practice for design and construction, BS 8110, London.
Federal Emergency Management Agency (FEMA). (2000). “Prestandard and commentary for the seismic rehabilitation of buildings.” FEMA 356, Washington, D.C.
Joh, O., Goto, Y., and Shibata, T. (1991). Behavior of reinforced concrete beam-column joints with eccentricity, SP-123, J. O. Jirsa, ed., American Concrete Institute, Farmington Hills, Mich., 317–357.
Joint ACI-ASCE Committee 352. (1985). “Recommendations for design of beam-column joints in monolithic reinforced concrete structures.” J. Am. Concr. Inst., 82(3), 266–283.
Lawrance, G. M, Beattie, G. J., and Jacks, D. H. (1991). “The cyclic load performance of an eccentric beam-column Joint.” Rep. No. 91-25126, Central Laboratories, Lower Hutt, New Zealand.
Li, B., Wu, Y. M., and Pan, T. C. (2002). “Seismic behaviour of nonseismically detailed interior beam-wide column joints—Part I: experimental results and observed behavior.” ACI Struct. J., 99(6), 791–802.
Paulay, T., and Priestley, M. J. N. (1992). Seismic design of reinforced concrete masonry buildings, Wiley, New York.
Raffaelle, G. S., and Wight, J. K. (1995). “Reinforced concrete eccentric beam-column connections subjected to earthquake-type loading.” ACI Struct. J., 92(1), 45–55.
Shin, M., and LaFave, J. M. (2004). “Seismic performance of reinforced concrete eccentric beam-column connections with floor slabs.” ACI Struct. J., 101(3), 403–412.
Standards New Zealand (1995). “Concrete structures standard (1995). Part 1: The design of concrete structure.” NZS 3101, New Zealand.
Teng, S., and Zhou, H. (2003). “Eccentric reinforced concrete beam-column joints subjected cyclic loading.” ACI Struct. J., 100(2), 139–148.
Information & Authors
Information
Published In
Copyright
© 2009 ASCE.
History
Received: Jun 25, 2007
Accepted: Mar 13, 2009
Published online: Jun 15, 2009
Published in print: Jul 2009
Notes
Note. Associate Editor: Yan Xiao
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.