Safety Assessment of Concrete Tunnel Linings under Fire Load
Publication: Journal of Structural Engineering
Volume 132, Issue 6
Abstract
An assessment of the structural performance of concrete tunnel linings under fire load is presented for the Lainzer Tunnel, a shallow tunnel recently constructed in Austria. Prior to the installation of the concrete lining at this tunnel, large-scale temperature experiments were conducted, revealing almost no reduction of the lining thickness in consequence of spalling for the employed lining concrete, reinforced by polypropylene fibers. In the absence of spalling, dehydration of concrete under high temperatures is the safety-determining process. Within the thermochemomechanical material model employed for the tunnel-safety assessment presented in this paper, dehydration is described by the decrease of the hydration extent, resulting in the reduction of both stiffness (thermal damage) and strength (thermal decohesion). The distribution of the hydration extent is determined by means of a thermochemical analysis. The obtained results serve as input for the subsequent chemomechanical analysis, providing insight into the deformation state of the ground-lining compound structure and the stress state in the lining. As a function of the stress state, a level of loading is introduced, with for the unloaded material and for stress states reaching the compressive strength of concrete. During fire exposure the size of increases because of increased loading by thermal expansion, on the other hand, and because of thermal decohesion resulting in a reduction of the compressive strength, on the other hand. The difference between 100% and represents the remaining load-carrying capacity of the lining, giving access to the safety of the tunnel for the chosen fire-accident scenario.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers thank Wolfgang Lindlbauer and Matthias Zeiml (Dr. Lindlbauer, Zivilingenieur für Bauwesen, Vienna, Austria) for the good cooperation within the research project outlined in Lindlbauer and Zeiml (2002). Helpful support by Johann Lemmerer and Oliver Wagner (both ÖBB-Infrastruktur Bau AG, Vienna, Austria), as well as financial support by the Austrian Science Fund under Contract Nos. UNSPECIFIEDP15912-N07 and UNSPECIFIEDP16517-N07 are gratefully acknowledged.
References
Coussy, O. (1995). Mechanics of porous continua, Wiley, Chichester, U.K.
Gawin, D., Pesavento, F., and Schrefler, B. A. (2002a). “A multiphase approach in the analysis of behaviour of concrete as porous-viscous material.” Proc., 5th World Conf. on Computational Mechanics, (CD-ROM), H. A. Mang, F. G. Rammerstorfer, and J. Eberhardsteiner, eds., Vienna, Austria, 1–10.
Gawin, D., Pesavento, F., and Schrefler, B. A. (2002b). “Simulation of damage-permeability coupling in hydro-thermo-mechanical analysis of concrete at high temperatures.” Commun. Numer. Methods Eng., 18(2), 113–119.
Haack, A., Meyeroltmanns, W., and Cabos, H. P. (2001). “Erkenntnisse aus Brandversuchen in Verkehrstunneln im Rahmen eines EUREKA-Forschungsprojektes (Findings from fire experiments in traffic tunnels in the framework of an EUREKA research project).” Technical Rep., Studiengesellschaft Stahlanwendung e.V., Düsseldorf, Germany (in German).
Kirkland, C. (2002). “The fire in the Channel Tunnel.” Tunn. Undergr. Space Technol., 17, 129–132.
Kusterle, W., et al. (2004). “Brandbeständigkeit von Faser-, Stahl- und Spannbeton (Fire resistance of fiber-reinforced, reinforced, and prestressed concrete).” Technical Rep. No. 544, Bundesministerium für Verkehr, Innovation und Technologie, Vienna, Austria (in German).
Lackner, R., Hellmich, C., and Mang, H. (2002a). “Constitutive modeling of cementitious materials in the framework of chemoplasticity.” Int. J. Numer. Methods Eng., 53(10), 2357–2388.
Lackner, R., Macht, J., and Mang, H. (2002b). “Projekt zur Erstellung eines Programmsystems zur praktischen Umsetzung eines hybriden Verfahrens zur Bestimmung der Beanspruchung von Tunnelschalen aus Spritzbeton (Project for the development of a program system for the practical realization of a hybrid method for determination of the loading of shotcrete tunnel shells).” Technical Rep., Univ. of Technology, Vienna, Austria (in German).
Lindlbauer, W., and Zeiml, M. (2002). “Forschungsvorhaben Brandbeständigkeit von Faser-, Stahl- und Spannbeton—Aufgabenstellung und Versuchsdurchführung (Research project on fire resistance of fiber-reinforced, reinforced, and prestressed concrete—concept, formulation, and implementation of experiments).” Schriftenreihe Österreichischen Vereinigung Beton- Bautechnik, 50, 67–74 (in German).
Macht, J., Lackner, R., Hellmich, C., and Mang, H. (2001). “Shotcrete creep properties—review of material tests and structural analyses of tunnels.” Proc., 6th Int. Conf. on Creep, Shrinkage & Durability Mechanics of Concrete and other Quasi-Brittle Materials, F.-J. Ulm, Z. Bazant, and F. Wittman, eds., Cambridge, Mass., Elsevier Science Ltd., Amsterdam, The Netherlands, 285–300.
Pichler, C., Lackner, R., Spira, Y., and Mang, H. (2003). “Thermochemomechanical assessment of ground improvement by jet grouting in tunneling.” J. Eng. Mech., 129(8), 951–962.
Talmann, W. (2003). “Erhaltung und Instandsetzung von Bauten aus Beton und Stahlbeton (Maintenance and repair of concrete and reinforced concrete structures).” Österreichische Vereinigung Beton- und Bautechnik, Vienna, Austria (in German).
Tenchev, R., Li, L., and Purkiss, J. (2001). “Finite element analysis of coupled heat and moisture transfer in concrete subjected to fire.” Numer. Heat Transfer, 39, 685–710.
Ulm, F.-J., Acker, P., and Lévy, M. (1999a). “The Chunnel fire. II: Analysis of concrete damage.” J. Eng. Mech., 125(3), 283–289.
Ulm, F.-J., Coussy, O., and Bažant, Z. (1999b). “The Chunnel fire. I: Chemoplastic softening in rapidly heated concrete.” J. Eng. Mech., 125(3), 272–282.
Ulm, F.-J., and Coussy, O. (1995). “Modeling of thermochemomechanical couplings of concrete at early ages.” J. Eng. Mech., 121(7), 785–794.
Wagner, O. (2004). “Lainzer Tunnel—Umsetzung einer wassundurchlässigen Innenschale (Lainzer Tunnel—realization of a waterproof invert).” Beton-und Stahlbetonbau, 99(2), 122–127 (in German).
Zeiml, M., Leithner, D., Lackner, R., and Mang, H. A. (2006). “How do polypropylene fibers improve the spalling behavior of in-situ concrete?” Cem. Concr. Res., 36(5), 929–942.
Information & Authors
Information
Published In
Copyright
© 2006 ASCE.
History
Received: Jun 20, 2002
Accepted: Oct 25, 2005
Published online: Jun 1, 2006
Published in print: Jun 2006
Notes
Note. Associate Editor: Sashi K. Kunnath
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.