Experimental Behavior of High Strength Square Concrete-Filled Steel Tube Beam-Columns
This article has a reply.
VIEW THE REPLYPublication: Journal of Structural Engineering
Volume 128, Issue 3
Abstract
The flexural force-deformation behavior of high strength square concrete-filled steel tube (CFT) beam-columns was experimentally investigated. The parameters in the study included the width-to-thickness ratio, the yield stress of the steel tube, and the axial load level. Eight CFT beam-column specimens were tested under constant axial load and monotonically increasing flexural loading. The CFT specimens were 305-mm square tubes with nominal ratios of 32 or 48, made from either conventional (A500 Grade-B) or high strength (A500 Grade-80) steel, and filled with high strength (110 MPa) concrete. Experimental results indicate that the moment capacity of CFT beam-columns is reached as inelastic behavior of the steel tube and concrete infill is combined with local buckling of the steel tube and crushing of the concrete. The moment capacity of high strength square CFT beam-columns can be predicted with reasonable accuracy using the current American Concrete Institute code provisions for composite columns. The curvature ductility of high strength square CFT beam-columns decreases significantly with an increase in either the axial load level or the ratio of the steel tube. The yield stress of the steel tube does not seem to have a significant influence on curvature ductility.
Get full access to this article
View all available purchase options and get full access to this article.
References
Aho, M. F., and Leon, R. T. (1997). “A database for encased and concrete-filled columns.” Rep. No. 97-01, Georgia Institute of Technology, School of Civil and Environmental Engineering, Atlanta.
American Concrete Institute (ACI). (1999). “Building code requirements for structural concrete (ACI 318-99) and commentary.” ACI 318R-99, Fermington Hills, Mich.
American Institute of Steel Construction (AISC). (1999). Load and resistance factor design (LRFD) specification for structural steel buildings, Chicago.
Architectural Institute of Japan (AIJ). (1987). Structural calculations of steel reinforced concrete structures, Tokyo.
ASTM. (1997a). Test methods for tension testing of metallic materials, E8, American Society for Testing and Materials, W. Conshohocken, Pa.
ASTM. (1997b). Standard test method for compressive strength test of cylindrical concrete specimens, C39-89, American Society for Testing and Materials, W. Conshohocken, Pa.
Bridge, R. Q. (1976). “Concrete filled steel tubular columns.” Research Rep. No. R283, Center for Advanced Structural Engineering, Dept. of Civil Engineering, Univ. of Sydney, Sydney, Australia.
Building Seismic Safety Council (BSSC). (1998). 1997 Ed. NEHRP recommended provisions for seismic regulations for new buildings and other structures, Washington, D.C.
Cederwall, K., Engstorm, B., and Grauers, M. (1991). “High strength concrete used in composite columns.” Proc., 2nd Int. Symposium on Utilization of High-Strength Concrete, American Concrete Institute, Detroit, 195–214.
European Committee for Standardization (ECS). (1994). “Eurocode 4: Design of composite steel and concrete structures.” Brussels.
Elremaily, A., Azizinamini, A., and Filipou, F. C. (1998). “Connection details for connecting steel beams to circular concrete filled tubes.” Structural Engineering World Wide 1998: Proc., Structural Engineering World Congress, Elsevier Science Ltd., Oxford, England, paper T169-2.
Furlong, R. W.(1967). “Strength of steel-encased concrete beam-columns.” J. Struct. Eng., 93(ST5), 113–125.
Furlong, R. W.(1968). “Design of steel-encased concrete beam-columns.” J. Struct. Eng., 94(ST1), 267–281.
Gourley, B. C., Hajjar, J. F., and Schiller, P. H. (1995). “A synopsis of studies of the monotonic and cyclic behavior of concrete-filled steel tube beam-columns.” Rep. No. ST-93-5-2, Dept. of Civil and Environmental Engineering, University of Minnesota, Minneapolis.
Ichinohe, Y., Matsutani, T., Nakajima, M., Ueda, H., and Takada, K. (1991), “Elasto-plastic behavior of concrete filled steel circular columns,” Proc., 3rd Int. Conf. on Steel-Concrete Composite Structures, ICCS-3 Conference Committee, Dept. of Architecture, Kyushu Univ., Fukuoka, Japan, 131–136.
Kilpatrick, A. E., and Rangan, B. V.(1999). “Tests on high-strength concrete-filled steel tubular columns.” ACI Struct. J., 96(2), 268–274.
Knowles, R. B., and Park, R.(1969). “Strength of concrete filled steel tubular columns.” J. Struct. Eng., 95(ST12), 2565–2587.
Lu, Y., and Kennedy, D.(1994). “Flexural behavior of concrete-filled hollow structural sections,” Can. J. Civ. Eng., 21(1), 110–130.
O’Shea, M. D., and Bridge, R. Q. (1997). “Tests on circular thin-walled steel tubes filled with very high strength concrete.” Research Rep. No. R754, Center for Advanced Structural Engineering, Dept. of Civil Engineering, Univ. of Sydney, Sydney, Australia.
Prion, H. G. L., and Boehme, J.(1994). “Beam-column behavior of steel tubes filled with high strength concrete.” Can. J. Civ. Eng., 21(2), 207–218.
Ricles, J. M., and Paboojian, S. D.(1994). “Seismic performance of steel encased composite columns.” J. Struct. Eng., 120(8), 2474–2494.
Sakino, K., and Nakahara, H. (2000). “Flexural capacities of concrete filled square steel tubular beam-columns with high strength concrete.” Composite and Hybrid Structures: Proc., 6th ASCCS Int. Conf. on Steel-Concrete Composite Structures, S. A. Mahin and Y. Xiao, eds., ASCCS-6 Secretariat, Dept. of Civil Engineering, Univ. of Southern California, Los Angeles, 473–480.
Shakir-Khalil, H., and Mouli, M.(1990). “Further tests on concrete-filled rectangular hollow-section columns.” Struct. Eng./Earthquake Eng., 68(20), 405–413.
Tomii, M., and Sakino, K.(1979a). “Experimental studies on the ultimate moment of concrete filled square steel tubular beam-columns.” Trans. Architectural Inst. Japan, 275, 55–63.
Tomii, M., and Sakino, K.(1979b). “Elasto-plastic behavior of concrete filled square steel tubular beam-columns.” Trans. Architectural Inst. Japan, 280, 111–120.
Tomii, M., Matsui, C., and Sakino, K. (1974). “Concrete-filled steel tube structures.” Proc., National Conf. on Planning and Design of Tall Buildings, Architectural Institute of Japan, Tokyo, 55–72.
Varma, A. H., Hull, B. K., Ricles, J. M., Sause, R., and Lu, L. W. (2001). “Seismic behavior, analysis, and design of high strength square CFT columns.” ATLSS Rep. No. 2001-02. ATLSS Research Center, Dept. of Civil and Environmental Engineering, Lehigh Univ., Bethlehem, Pa.
Varma, A. H., Ricles, J. M., Sause, R., Hull, B., and Lu, L. W. (2000). “An experimental evaluation of high strength square CFT columns.” ACI SP-196: Composite and Hybrid Systems, R. S. Aboutaha and J. M. Bracci, eds., ACI, Farmington Hills, Mich., 51–86.
Zhang, W., and Shahrooz, B. M. (1997). “Analytical and experimental studies into behavior of concrete-filled tubular columns.” Rep. No. UC-CII 97/01, Cincinnati Infrastructure Institute, Dept. of Civil and Environmental Engineering, Univ. of Cincinnati.
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Received: Jul 31, 2000
Accepted: Aug 13, 2001
Published online: Mar 1, 2002
Published in print: Mar 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation