Light‐Scatter Particle Counting: Improving Filtered‐Water Quality
Publication: Journal of Environmental Engineering
Volume 117, Issue 2
Abstract
Forward‐angle light‐scatter (FALS) particle counting is investigated as a means to quantify and improve filtered‐water quality in drinking‐water treatment. In the laboratory, FALS particle counts are found to be precise and reproducible by multiple analysts when proper sample handling procedures are followed. In FALS counts of water samples with added Giardia cysts, FALS categorizes Giardia cysts as equivalent to spheres of 1–5 μm in diameter, demonstrating the importance of using a particle counter to size particles of interest prior to selecting size ranges for routine monitoring. In full‐scale water‐treatment plant trials, FALS particle counts are used to show that particles in filtered water are substantially reduced when filter operation is changed from intermittent, fixed rate, 60‐hour filter runs to continuously operated, variable rate, with 48 hours between backwashes. Filtered‐water quality is also higher in stage 2 of the Bearspaw Water Treatment Plant than in stage 1 under all operating conditions. Turbidity measurements follow trends in particle counts in most cases. Further improvements in filtered‐water quality can likely be made by using FALS particle counting to optimize backwashing procedures and filter‐ripening strategies.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Al‐Ani, M. Y., Hendricks, D. W., Logsdon, G. S., and Hibler, C. P. (1986). “Removing Giardia cysts from low turbidity waters by rapid rate filtration.” J. Am. Water Works Assoc., 78, 66–73.
2.
Al‐Ani, M. Y., McElroy, J. M., Hibler, C. P., and Hendricks, D. W. (1985). “Filtration of Giardia cysts of other substances: Volume 3. Rapid rate filtration.” EPA/600/2‐85/027, U.S. Envir. Protection Agency, Cincinnati, Ohio.
3.
Amirtharajah, A. (1988). “Some theoretical and conceptual views of filtration.” J. Am. Water Works Assoc., 80(12), 36–46.
4.
Beard, J. D. II, and Tanaka, T. S. (1976). “A comparison of particle counting and nephelometry in evaluating filtration plant performance.” Proc. Tech. Conf., American Waterworks Association, 1–27.
5.
Beard, J. D. II, and Tanaka, T. S. (1977). “A comparison of particle counting and nephelometry.” J. Am. Water Works Assoc., 69(10), 533–538.
6.
Bucklin, K., Amirtharajah, A., and Cranston, K. O. (1988). The characteristics of initial effluent quality and its implications for the filter to waste procedure. American Waterworks Association, Denver, Colo.
7.
Cleasby, J. L. (1983). “Slow sand filtration and direct in‐line filtration of a surface water.” Proc. Amer. Waterworks Association Sunday Seminar on Innovative Filtration Techniques, American Waterworks Association, Denver, Colo.
8.
Cleasby, J. L., Dharmarajah, A. H., Sindt, G. L., and Baumann, E. R. (1989). Design and operation guidelines for optimization of the high‐rate filtration process: Plant survey results, AWWA Research Foundation and American Water Works Association, Denver, Colo.
9.
Craun, G. F. (1986). Waterborne diseases in the United States. CRC Press, Inc., Boca Raton, Fla.
10.
Davies, R. B., Fukutaki, K., and Hibler, C. P. (1983). “Cross transmission of Giardia.” PB83‐117‐747, Nation Technical Information Service, Cincinnati, Ohio.
11.
Hibler, C. P., Hancock, C. M., Perger, L. M., Wegrzyn, J. G., and Swabby, K. D. (1989). “Inactivation of Giardia cysts with chlorine at 0.5° C to 5.0° C.” New developments in drinking water technology, American Waterworks Association Research Foundation, Denver, Colo.
12.
Hilmoe, D. J., and Cleasby, J. L. (1986). “Comparing constant‐rate and declining‐rate direct filtration of a surface water.” J. Am. Water Works Assoc., 78(12), 26–34.
13.
Hutchinson, C. W. (1985a). “On‐line particle counting for filtration control.” ISA Trans., 24(3), 75–82.
14.
Hutchinson, C. W. (1985b). “On‐line particle counting improves filter efficiency.” Water Eng. Manage., Jul., 20–25.
15.
Jekel, J. R. (1982). “Zun einsatz von partikelgrobenanallysen in der trinkwasser‐aufbereitung.” GWF Wasser/abwasser, 123, 555–560.
16.
Lewis, C. M. (1989). “Forward angle light scatter particle counting: Improving filtered water quality,” thesis presented to the University of Calgary, at Calgary, Alberta, Canada, in partial fulfillment of the requirements for the degree of Master of Science.
17.
Logsdon, G. S. (1987). “Evaluating treatment plants for particulate contaminant removal.” J. Am. Water Works Assoc., 79(9), 82–92.
18.
Logsdon, G. S., and Fox, K. (1982). “Getting your money's worth from filtration.” J. Am. Water Works Assoc., 74(5), 249–255.
19.
Logsdon, G. S., Thurman, V. C., Frindt, E. S., and Stoecker, J. G. (1985). “Evaluating sedimentation and various filter media for removal of Giardia cysts.” J. Am. Water Works Assoc., 77(2), 61–66.
20.
Mason, L. (1987). “Experience with Cryptosporidium at Carrollton, Georgia.” Proc. Tech. Conf.: Issues and Answers for Today's Water Quality Professional. American Waterworks Association, 887–898.
21.
McTigue, N. E., and Cornwall, D. A. (1988). “The use of particle counting for the evaluation of filter performance.” Proc. Amer. Water Works Association Seminar Filtration: Meeting New Standards, American Waterworks Association, 47–74.
22.
Monscvitz, J. T., and Rexing, D. J. (1983). “Direct filtration control by particle counting.” Proc. Amer. Waterworks Association 1983 Annual Conf., American Waterworks Association.
23.
“A 1987 outbreak of Cryptosporidium.” (1989). Water Newsletter, 31(10), 1.
24.
Operation and maintenance manual for model 346‐B/346BCL. (1984). Hiac‐Royco Instrument Co., Menlo Park, Calif.
25.
Operation and maintenance manual for model 3200 tank sampler. (1984b). Hiac‐Royco Instrument Co., Menlo Park, Calif.
26.
Operation and maintenance manual for model 4100/4150 particle counter. (1984a). Hiac‐Royco Instrument Co., Menlo Park, Calif.
27.
Rose, J. B. (1988). “Occurrence and significance of Cryptosporidium in water.” J. Am. Water Works Assoc., 80(2), 53–58.
28.
Silverman, G. P. (1988). “Cryptosporidium—the industry's new superbug.” Opflow, Sep. 4–5.
29.
Tate, C. H., and Trussell, R. R. (1976). “Optimization of turbidity removal by use of particle counting for developing plant design criteria.” Proc. Tech. Conf., American Waterworks Association, 1–27.
30.
Tate, C. H., and Trussell, R. R. (1978). “The use of particle counting in developing plant design criteria.” J. Am. Water Works Assoc., 70(12), 691–698.
31.
Trussell, R. R., and Tate, C. H. (1979). “Measurement of particle size distribution in water treatment.” Proc. Amer. Waterworks Association Water Quality Tech. Conf., American Waterworks Association, 19–39.
Information & Authors
Information
Published In
Copyright
Copyright © 1991 ASCE.
History
Published online: Mar 1, 1991
Published in print: Mar 1991
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.