Cost-Benefit Analysis for Hydropower Production in Water Distribution Networks by a Pump as Turbine
Publication: Journal of Water Resources Planning and Management
Volume 140, Issue 6
Abstract
The use of microhydroelectric plants in urban pipe networks, based on the combination of a pump as turbine (PAT), two regulating valves, and two pressure meters, is proposed along with simple automation rules. Its economic benefit is tested on a small pipe network, where the network geometry as well as the demand coefficient variation in time and space have been inferred from previously collected data and existing analysis. A similar analysis has been also carried out for different scenarios in which the reduction of pipe installation cost due to a diameter reduction is compared with the increased benefit in energy production. The case study shows that a small increment of the pipe installation cost, with respect to the minimum required by the nodes minimum pressure, can lead to a larger benefit for energy production.
Get full access to this article
View all available purchase options and get full access to this article.
References
Afshar, A., Jemaa, F., and Marino, M. (1990). “Optimization of hydropower plant integration in water supply system.” J. Water Resour. Plann. Manage., 665–675.
Aggidis, G., Luchinskaya, E., Rothschild, R., and Howard, D. (2010). “The costs of small-scale hydro power production: Impact on the development of existing potential.” Renewable Energy, 35(12), 2632–2638.
Almandoz, J., Cabrera, E., Arregui, F., Cabrera, E., and Cobacho, R. (2005). “Leakage assessment through water distribution network simulation.” J. Water Resour. Plann. Manage., 458–466.
Araujo, L., Ramos, H., and Coelho, S. (2006). “Pressure control for leakage minimisation in water distribution systems management.” Water Resour. Manage., 20(1), 133–149.
Arriaga, M. (2010). “Pump as turbine—A pico-hydro alternative in Lao People’s Democratic Republic.” Renew. Energy, 35(5), 1109–1115.
Carravetta, A., Del Giudice, G., Fecarotta, O., and Ramos, H. (2013). “Pat design strategy for energy recovery in water distribution networks by electrical regulation.” Energies, 6(1), 411–424.
Carravetta, A., Del Giudice, G., Fecarotta, O., Ramos, H. (2012). “Energy production in water distribution networks: A PAT design strategy.” Water Resour Manage, 26(13), 3947–3959.
Carravetta, A., Fecarotta, O., and Ramos, H. (2011). “Numerical simulation on pump as turbine: Mesh reliability and performance concerns.” Int. Conf. on Clean Electrical Power, Ischia, Franco Angeli ed, Milano.
Carravetta, A., and Giugni, M. (2009). “Functionality factors in the management and rehabilitation of water networks.” Management of Water Networks, Proc. Conf. Efficient Management of Water Networks. Design and Rehabilitation Techniques, Franco Angeli ed, Milano.
Chapallaz, J., Eichenberger, P., and Fischer, G. (1992). Manual on pumps used as turbines, DeutschesZentru fur Entwicklungstechnologien, GATE, Eschborn, Germany.
Cunha, M., and Sousa, J. (1999). “Water distribution network design optimization: Simulated annealing approach.” J. Water Resour. Plann. Manage., 215–221.
De Marchis, M., Fontanazza, C., Freni, G., La Loggia, G., Napoli, E., and Notaro, V. (2011). “Analysis of the impact of intermittent distribution by modelling the network-filling process.” J. Hydroinform., 13(3), 358–373.
Desai, V., and Aziz, N. (1994). “Power outputs of two stages of cross-flow turbine.” J. Fluids Eng., 116(3), 545–550.
EPANET [Computer software]. Cincinnati, OH, EPA.
Fecarotta, O., Carravetta, A., and Ramos, H. (2011). “CFD and comparisons for a pump as turbine: Mesh reliability and performance concerns.” Int. J. Energy Environ., 2(1), 39–48.
Fernandez, J., Blanco, E., Parrondo, J., Stickland, M., and Scanlon, T. (2004). “Performance of a centrifugal pump running in inverse mode.” Proc. Inst. Mech. Eng. A J. Power Energy, 218(4), 265–271.
Filion, Y., MacLean, H., and Karney, B. (2004). “Life cycle energy analysis of a water distribution system.” J. Infrastruct. Syst., 120–130.
Fiuzat, A., and Akerkar, B. (1991). “Power outputs of two stages of cross-flow turbine.” J. Energy Eng., 57–70.
Fontana, N., Giugni, M., and Portolano, D. (2012). “Losses reduction and energy production in water-distribution networks.” J. Water Resour. Plann. Manage., 237–244.
Gaius-obaseki, T. (2010). “Hydropower opportunities in the water industry.” Int. J. Environ. Sci., 1(3), 392–402.
Karadirek, I., Kara, S., Yilmaz, G., Muhammetoglu, A., and Muhammetoglu, H. (2012). “Implementation of hydraulic modelling for water-loss reduction through pressure management.” Water Resour. Manage., 26(9), 2555–2568.
Khosrowpanah, S., Albertson, M., and Fiuzat, A. (1984). “Historical overview of cross-flow turbine.” Int. Water Power Dam Constr., 36(10), 38–43.
Khurana, S., and Kumar, A. (2011). “Small hydro power—A review.” Int. J. Therm. Technol., 11(1), 107–110.
Liberatore, S., and Sechi, G. (2009). “Location and calibration of valves in water distribution networks using a scatter-search meta-heuristic approach.” Water Resour. Manage., 23(8), 1479–1495.
McNabola, A., Coughlan, P., and Williams, A. (2011). “The technical and economic feasibility of energy recovery in water supply networks.” Int. Conf. on Renewable Energy and Power Quality, Las Palmas de Gran Canaria, European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ).
Morga, F., Termini, D., and Viviani, G. (2007). “Calibrazione dei parametri di qualità nelle reti di approvvigionamento idrico e caratterizzazione della diversità spaziale—Applicazione ad un caso di studio.” Approvvigionamento e Distribuzione Idrica: Esperienze, Ricerca ed Innovazione, Morlacchi Editore, Ferrara, Italy (in Italian).
Nazif, S., Karamouz, M., Tabesh, M., and Moridi, A. (2010). “Pressure management model for urban water distribution networks.” Water Resour. Manage., 24(3), 437–458.
Paish, O. (2002). “Small hydro power: Technology and current status.” Renew. Sustain. Energy Rev., 6(6), 537–556.
Prasad, T., and Park, N. (2004). “Multiobjective genetic algorithms for design of water distribution networks.” J. Water Resour. Plann. Manage., 73–82.
Prescott, S., and Ulanicki, B. (2008). “Improved control of pressure reducing valves in water distribution networks.” J. Hydraul. Eng., 56–65.
Punys, P., Dumbrauskas, A., Kvaraciejus, A., and Vyciene, G. (2011). “Tools for small hydropower plant resource planning and development: A review of technology and applications.” Energies, 4(9), 1258–1277.
Ramos, H., and Borga, A. (1999). “Pumps as turbines: An unconventional solution to energy production.” Urban Water, 1(3), 261–263.
Ramos, H., and Borga, A. (2000). “Pumps yielding power.” Dam Eng., 10(4), 197–217.
Ramos, H., Covas, D., Araujo, L., and Mello, M. (2005). “Available energy assessment in water supply systems.” XXXI IAHR Congress, IAHR, Madrid.
Ramos, H., Mello, M., and De, P. (2010). “Clean power in water supply systems as a sustainable solution: From planning to practical implementation.” Water Sci. Technol., 10(1), 39–49.
Ramos, H. M., Kenov, K. N., and Vieira, F. (2011). “Environmentally friendly hybrid solutions to improve the energy and hydraulic efficiency in water supply systems.” Energy Sustain. Dev., 15(4), 436–442.
Rossman, L. (2000). EPANET 2 users manual, National Risk Management Research Laboratory, Office of Research and Developement, U.S. Environmental Protection Agency, Cincinnati.
Sammartano, V., Aricò, C., Carravetta, A., Fecarotta, O., and Tucciarelli, T. (2013). “Banki-Michell optimal design by computational fluid dynamics testing and hydrodynamic analysis.” Energies, 6(5), 2362–2385.
Sopian, K., and Razak, J. (2009). “Pico hydro: Clean power from small streams.” Proc., 3rd WSEAS Int. Conf. on Renewable Energy Sources, WSEAS, Athens.
Tucciarelli, T., Criminisi, A., and Termini, D. (1999). “Leak analysis in pipeline systems by means of optimal valve regulation.” J. Hydraul. Eng., 277–285.
Vairavamoorthy, K., and Lumbers, J. (1998). “Leakage reduction in water distribution systems: Optimal valve control.” J. Hydraul. Eng., 1146–1154.
Vasan, A., and Simonovic, S. (2010). “Optimization of water distribution network design using differential evolution.” J. Water Resour. Plann. Manage., 279–287.
Walsky, T., Bezts, W., Posluzny, E., Weir, M., and Withman, B. (2006). “Modeling leakage reduction through pressure control.” J. Am. Water Works Assoc., 98(4), 148–155.
Zakkour, P., Gatarell, M., Gochin, R., and Lester, J. (2002). “Developing a sustainable energy strategy for a water utility. Part II: A review of potential technologies and approaches.” J. Environ. Manage., 66(2), 115–125.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Dec 3, 2012
Accepted: Jun 10, 2013
Published online: Jun 13, 2013
Published in print: Jun 1, 2014
Discussion open until: Aug 14, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.