Residual Seismic Performance of Fire-Damaged Reinforced Concrete Frame Structure with Metallic Yielding Dampers
Publication: Journal of Structural Engineering
Volume 148, Issue 4
Abstract
Structures with varying dampers have been widely designed and constructed for earthquake resistance. However, the residual seismic performance of these damped structures could not be guaranteed after being exposed to a fire because both the primary structure and dampers are vulnerable to high temperatures. The postfire residual seismic performance is an important design index for damped structures whereas no research has been done so far to determine such residual performance. Therefore, this study serves as the first attempt by exploiting the widely constructed RC frame structure with commonly investigated metallic yielding dampers (MYDs) as an example to investigate its residual seismic performance after being exposed to a fire. One story of a RC office building is employed as the single-degree-of-freedom (SDOF) analytical model, and then the mechanical and geometric parameters of MYDs are derived via the design method from the perspective of the uniform damping ratio. In addition, the gas temperature of the natural fire curves is determined according to current European standards, and 16 representative fire scenarios are selected. Moreover, the residual material properties and residual performance of the primary structure as well as MYD are investigated and expressed in mathematical forms. Thereon, the linear forms of the restoring forces of the primary structure and MYD are obtained by utilizing the equivalent linearization method, and the motion-governing and energy-conservation equations are established. Furthermore, the methodology for the parametric analysis is put forward, and the residual seismic performance of the fire-damaged damped structure is derived quantitatively, which is also verified via time-domain analysis with recorded ground motions. The results show that the seismic performance of the SDOF concrete structure with MYD can be reduced significantly by fire damage.
Get full access to this article
View all available purchase options and get full access to this article.
Data Availability Statement
Some or all data, models, or codes that support the findings of this study are available from the corresponding author upon reasonable request.
Acknowledgments
Financial support from the National Natural Science Foundation of China through Grant No. 51978525 is highly appreciated. The authors would also like to thank Professor Xiaojia Shelly Zhang of University of Illinois at Urbana-Champaign for proofreading this work.
References
ACI (American Concrete Institute). 2007. Code requirements for determining fire resistance of concrete and masonry construction assemblies. Detroit: ACI.
Asai, T., Y. Araki, and K. Ikago. 2017. “Energy harvesting potential of tuned inertial mass electromagnetic transducers.” Mech. Syst. Sig. Process. 84 (Feb): 659–672. https://doi.org/10.1016/j.ymssp.2016.07.048.
BSI (British Standard Institution). 2002. Eurocode 1: Actions on structures–Part 1-2: General actions–Actions on structures exposed to fire. BS EN 1991-1-2-2002. London: BSI.
BSI (British Standard Institution). 2004a. Eurocode 2: Design of concrete structures–Part 1-1: General rules and rules for buildings. BS EN 1992-1-1:2004. London: BSI.
BSI (British Standard Institution). 2004b. Eurocode 2: Design of concrete structures–Part 1-2: General rules–Structural fire design. BS EN 1992-1-2:2004. London: BSI.
BSI (British Standard Institution). 2005. Eurocode 3: Design of steel structures–Part 1-2: General rules–Structural fire design. BS EN 1993-1-2:2005. London: BSI.
Buchanan, A. H., and A. K. Abu. 2017. Structural design for fire safety. Chichester, UK: Wiley.
China Ministry of Housing and Urban-Rural Construction. 2015. Chinese code for design of concrete structures. GB 50010-2010. Beijing: China Architecture & Building Press.
China Ministry of Housing and Urban-Rural Construction. 2016a. Chinese code for seismic design of buildings. GB 50011-2010. Beijing: China Architecture & Building Press.
China Ministry of Housing and Urban-Rural Construction. 2016b. Chinese code for thermal design of civil building. GB 50176-2016. Beijing: China Architecture & Building Press.
Chipperfield, A. J. 1995. “The Matlab genetic algorithm toolbox.” In IEE colloquium on applied control techniques using MATLAB, 10–10. London: Institution of Electrical Engineers.
Dassault Systemes Simulia Corporation. 2014. Abaqus: A finite element analysis software. Providence, RI: Simulia.
Gutierrez Soto, M., and H. Adeli. 2013. “Tuned mass dampers.” Arch. Comput. Methods Eng. 20 (4): 419–431. https://doi.org/10.1007/s11831-013-9091-7.
Harmathy, T. Z., and M. A. Sultan. 1988. “Correlation between the severities of the ASTM E119 and ISO 834 fire exposures.” Fire Saf. J. 13 (2): 163–168. https://doi.org/10.1016/0379-7112(88)90011-2.
Hurtado, J. E., and A. H. Barbat. 2000. “Equivalent linearization of the Bouc–Wen hysteretic model.” Eng. Struct. 22 (9): 1121–1132. https://doi.org/10.1016/S0141-0296(99)00056-5.
Ikago, K., K. Saito, and N. Inoue. 2012. “Seismic control of single-degree-of-freedom structure using tuned viscous mass damper.” Earthquake Eng. Struct. Dyn. 41 (3): 453–474. https://doi.org/10.1002/eqe.1138.
Jia, Y., L. Li, C. Wang, Z. Lu, and R. Zhang. 2019. “A novel shape memory alloy damping inerter for vibration mitigation.” Smart Mater. Struct. 28 (11): 115002. https://doi.org/10.1088/1361-665X/ab3dc8.
Jia, Y., Z. Lu, L. Li, and C. Wang. 2020. “A hybrid steel–shape memory alloy prestressed concrete beam for improved fire resistance.” Struct. Control Health Monit. 27 (10): e2601. https://doi.org/10.1002/stc.2601.
Jin, L., R. Zhang, G. Dou, and X. Du. 2018. “Fire resistance of steel fiber reinforced concrete beams after low-velocity impact loading.” Fire Saf. J. 98 (Jun): 24–37. https://doi.org/10.1016/j.firesaf.2018.04.003.
Kelly, J. M., R. Skinner, and A. Heine. 1972. “Mechanisms of energy absorption in special devices for use in earthquake resistant structures.” Bull. N. Z. Soc. Earthquake Eng. 5 (3): 63–88. https://doi.org/10.5459/bnzsee.5.3.63-88.
Kodur, V. K. R., B. Yu, and M. M. S. Dwaikat. 2013. “A simplified approach for predicting temperature in reinforced concrete members exposed to standard fire.” Fire Saf. J. 56 (Feb): 39–51. https://doi.org/10.1016/j.firesaf.2012.12.004.
Li, W. S., and X. W. Deng. 2011. “The temperature field finite element analysis of concrete beam after fire based on Abaqus.” Appl. Mech. Mater. 90–93 (Sep): 3089–3092. https://doi.org/10.4028/www.scientific.net/AMM.90-93.3089.
Lie, T. T., and E. M. A. Denham. 1993. Factors affecting the fire resistance of circular hollow steel columns filled with bar-reinforced concrete. Ottawa: National Research Council of Canada, Institute for Research in Construction.
Lin, J., W. Zhang, and F. W. Williams. 1994. “Pseudo-excitation algorithm for nonstationary random seismic responses.” Eng. Struct. 16 (4): 270–276. https://doi.org/10.1016/0141-0296(94)90067-1.
Lin, J., and Y. Zhang. 2004. Pseudo excitation method for random vibration. Beijing: Science Press.
Lin, J. H., Y. H. Zhang, and Y. Zhao. 2011. “Pseudo excitation method and some recent developments.” Procedia Eng. 14 (Jan): 2453–2458. https://doi.org/10.1016/j.proeng.2011.07.308.
Maraveas, C., Z. C. Fasoulakis, and K. D. Tsavdaridis. 2017a. “Mechanical properties of high and very high steel at elevated temperatures and after cooling down.” Fire Sci. Rev. 6 (1): 1–13. https://doi.org/10.1186/s40038-017-0017-6.
Maraveas, C., Z. C. Fasoulakis, and K. D. Tsavdaridis. 2017b. “Post-fire assessment and reinstatement of steel structures.” J. Struct. Fire Eng. 8 (2): 181–201. https://doi.org/10.1108/JSFE-03-2017-0028.
Mazza, F. 2015. “Seismic vulnerability and retrofitting by damped braces of fire-damaged R.C. framed buildings.” Eng. Struct. 101 (Oct): 179–192. https://doi.org/10.1016/j.engstruct.2015.07.027.
Mazza, F. 2016. “Effects of near-fault vertical earthquakes on the nonlinear incremental response of R.C. base-isolated structures exposed to fire.” Bull. Earthquake Eng. 14 (2): 433–454. https://doi.org/10.1007/s10518-015-9826-y.
Mazza, F. 2017. “Behaviour during seismic aftershocks of R.C. base-isolated framed structure with fire-induced damage.” Eng. Struct. 140 (Jun): 458–472. https://doi.org/10.1016/j.engstruct.2017.03.008.
Mazza, F., and A. Vulcano. 2010. “Nonlinear dynamic response of R.C. framed structures subjected to near-fault ground motions.” Bull. Earthquake Eng. 8 (6): 1331–1350. https://doi.org/10.1007/s10518-010-9180-z.
McKenna, F. 2011. “OpenSees: A framework for earthquake engineering simulation.” Comput. Sci. Eng. 13 (4): 58–66. https://doi.org/10.1109/MCSE.2011.66.
Ni, S., and A. C. Birely. 2018. “Post-fire seismic behavior of reinforced concrete structural walls.” Eng. Struct. 168 (Aug): 163–178. https://doi.org/10.1016/j.engstruct.2018.04.018.
Oliphant, T. E. 2007. “Python for scientific computing.” Comput. Sci. Eng. 9 (3): 10–20. https://doi.org/10.1109/MCSE.2007.58.
Oliveira, F., M. A. Botto, P. Morais, and A. Suleman. 2018. “Semi-active structural vibration control of base-isolated buildings using magnetorheological dampers.” J. Low Freq. Noise Vibr. Act. Control 37 (3): 565–576. https://doi.org/10.1177/1461348417725959.
Pan, C., and R. Zhang. 2018. “Design of structure with inerter system based on stochastic response mitigation ratio.” Struct. Control Health Monit. 25 (6): e2169. https://doi.org/10.1002/stc.2169.
Quayyum, S., and T. Hassan. 2018. “Seismic performance of a fire-exposed moment-resisting frame.” J. Struct. Eng. 144 (11): 04018206. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002201.
Rofooei, F. R., A. Mobarake, and G. Ahmadi. 2001. “Generation of artificial earthquake records with a nonstationary Kanai–Tajimi model.” Eng. Struct. 23 (7): 827–837. https://doi.org/10.1016/S0141-0296(00)00093-6.
Wen, Y.-K. 1976. “Method for random vibration of hysteretic systems.” J. Eng. Mech. Div. 102 (2): 249–263. https://doi.org/10.1061/JMCEA3.0002106.
Witek, A., D. Gawin, F. Pesavento, and B. A. Schrefler. 2006. “Finite element analysis of various methods for protection of concrete structures against spalling during fire.” Comput. Mech. 39 (3): 271–292. https://doi.org/10.1007/s00466-005-0024-7.
Xu, L., Y. Yu, and Y. Cui. 2018. “Active vibration control for seismic excited building structures under actuator saturation, measurement stochastic noise and quantisation.” Eng. Struct. 156: 1–11. https://doi.org/10.1016/j.engstruct.2017.11.021.
Zhang, R., C. Wang, C. Pan, H. Shen, Q. Ge, and L. Zhang. 2018. “Simplified design of elastoplastic structures with metallic yielding dampers based on the concept of uniform damping ratio.” Eng. Struct. 176: 734–745. https://doi.org/10.1016/j.engstruct.2018.09.009.
Information & Authors
Information
Published In
Copyright
© 2022 American Society of Civil Engineers.
History
Received: Apr 24, 2021
Accepted: Oct 28, 2021
Published online: Jan 17, 2022
Published in print: Apr 1, 2022
Discussion open until: Jun 17, 2022
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.
Cited by
- Ying Qin, Ke-Xue Zhao, Gan-Ping Shu, Lu Ke, Experimental study on frictional behavior of different structural materials, Structures, 10.1016/j.istruc.2023.01.142, 49, (557-569), (2023).